Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BJS Open ; 1(1): 2-10, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29951599

RESUMO

BACKGROUND: The benefits of single-use ultrasonic scissors in thyroid surgery are still debated. Although this device has been shown to reduce operating time compared with conventional haemostasis, its cost-effectiveness has never been demonstrated. The aim of this study was to evaluate the efficacy, cost-effectiveness and safety of ultrasonic scissors for total thyroidectomy. METHODS: This was a prospective, randomized, multicentre trial conducted at 13 hospital sites. The primary endpoint was the percentage of patients with hypocalcaemia (serum calcium level below 2 mmol/l) on day 2. Secondary endpoints included postoperative complications and costs, with calculation of incremental cost differences and cost-effectiveness ratios. RESULTS: In total, 1329 patients who underwent total thyroidectomy were included in the analysis: 670 were randomized to treatment with ultrasonic scissors and 659 to conventional haemostasis. There was no difference between groups in the rate of complications, including hypocalcaemia on day 2 (19.7 per cent in ultrasonic scissors group versus 20.3 per cent in conventional haemostasis group; P = 0·743). Median operating times were significantly shorter with ultrasonic scissors (90 versus 100 min with conventional haemostasis; P < 0·001). Total mean(s.d.) direct costs at 6 months were €4311(1547) and €4011(1596) respectively (P < 0·001). CONCLUSION: Ultrasonic scissors were no more clinically effective than conventional haemostasis, but use of these devices was more costly. Registration number: NCT01551914 (http://www.clinicaltrials.gov).

2.
Exp Clin Endocrinol Diabetes ; 107(3): 214-9, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10376449

RESUMO

We describe simplified and rapid methods to assess islet function with the aim to develop better protocols for islet isolation and to determine islet characteristics before transplantation. These methods are also useful in the assessment of the potentially beneficial or deleterious effects of compounds added to the culture media in stimulation experiments. To this end, we took advantage of the multiscreen assay system produced by Millipore SA. This 96-well unit allowed the free-floating culture of islets on filter membranes, the rapid vacuuming and collection of conditioned media or reaction buffer and thus successive testing of the same number of islets, possibly at different culture times. We estimated islet viability by determination of the metabolic activity of cells, normal function of islets by their ability to metabolize glucose and to synthesize and secrete insulin and of nitrite release, a reflection of nitric oxide (NO) status of cells, which may be involved in a signaling pathway during glucose-stimulated insulin secretion or in cytokine inducible pathway. Assays may be performed either on selected islets or on aliquots of semi-purified preparations designated for grafting, allowing thus the rapid estimation of graft function of the entire preparation. This herein described system may be also extended to many other functional tests.


Assuntos
Transplante das Ilhotas Pancreáticas/normas , Ilhotas Pancreáticas/citologia , Ilhotas Pancreáticas/fisiologia , Automação , Separação Celular , Sobrevivência Celular , DNA/análise , Humanos , Insulina/análise , Nitritos/análise , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA