Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 47(11): 2487-2492, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32700058
2.
BMC Cancer ; 18(1): 1193, 2018 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-30497448

RESUMO

BACKGROUND: Osteosarcoma is the most common malignant bone tumor in children and young adults that produces aberrant osteoid. The aim of this study was to assess the utility of 2-deoxy-2-[18F-] fluoro-D-glucose ([18F] FDG) and sodium [18F] Fluoride (Na [18F] F) PET scans in orthotopic murine models of osteosarcoma to describe the metabolic pattern of the tumors, to detect and diagnose tumors and to evaluate the efficacy of a new treatment based in oncolytic adenoviruses. METHODS: Orthotopic osteosarcoma murine models were created by the injection of 143B and 531MII cell lines. [18F]FDG and Na [18F] F PET scans were performed 30 days (143B) and 90 days (531MII) post-injection. The antitumor effect of two doses (107 and 108 pfu) of the oncolytic adenovirus VCN-01 was evaluated in 531 MII model by [18F] FDG PET studies. [18F] FDG uptake was quantified by SUVmax and Total Lesion Glycolysis (TLG) indexes. For Na [18F] F, the ratio tumor SUVmax/hip SUVmax was calculated. PET findings were confirmed by histopathological techniques. RESULTS: The metabolic pattern of tumors was different between both orthotopic models. All tumors showed [18F] FDG uptake, with a sensitivity and specificity of 100%. The [18F] FDG uptake was significantly higher for the 143B model (p < 0.001). Sensitivity for Na [18F] F was around 70% in both models, with a specificity of 100%. 531MII tumors showed a heterogeneous Na [18F] F uptake, significantly higher than 143B tumors (p < 0.01). Importantly, [18F] FDG and Na [18F] F uptake corresponded to highly cellular or osteoid-rich tumors in the histopathological analysis, respectively. [18F] FDG data confirmed that the oncolytic treatment of 531MII tumors produced a significant reduction in growth even with the 107 pfu dose. CONCLUSIONS: PET studies demonstrated that the different osteosarcoma xenograft models developed tumors with diverse metabolic patterns that can be described by multitracer PET studies. Since not all tumors produced abundant osteoid, [18F] FDG demonstrated a better sensitivity for tumor detection and was able to quantitatively monitor in vivo response to the oncolytic adenovirus VCN-01.


Assuntos
Metabolismo Energético , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Osteossarcoma/diagnóstico por imagem , Osteossarcoma/metabolismo , Tomografia por Emissão de Pósitrons , Animais , Linhagem Celular Tumoral , Modelos Animais de Doenças , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Camundongos , Osteossarcoma/patologia , Osteossarcoma/terapia , Compostos Radiofarmacêuticos
3.
Nucl Med Commun ; 36(5): 414-22, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25646703

RESUMO

Radiopharmaceuticals are highly regulated, because they are controlled both as regular medicinal products and as radioactive substances. This can pose a hurdle for their development and clinical use. Radiopharmaceuticals are fundamentally different from other medicinal products and these regulations are not always adequate for their production. Strict compliance may have a huge resource impact, without further improving product quality. In this paper we give an overview of the applicable legislation and guidelines and propose a risk-based approach for their implementation. We focus on a few controversial Good Manufacturing Practice topics: cleanroom classification, air pressure regime, cleanroom qualification and microbiological monitoring. We have developed an algorithm to assess the combined risk of microbiological contamination of a radiopharmaceutical preparation process and propose corresponding Good Manufacturing Practice classification levels. In our opinion, the risk of carry-over of radiopharmaceuticals by individuals cannot be contained by pressure differences, and complicated regimes with underpressured rooms are not necessary in most situations. We propose a sterility assurance level of 10 for radiopharmaceuticals that are administered within a working day, irrespective of their use. We suggest the adoption of limits for environmental monitoring of microbial contamination, as proposed by Bruel and colleagues, on behalf of the French Society of Radiopharmacy. Recently launched regulatory documents seem to breathe a more liberal spirit than current legislation and recognize the need for the use of risk assessment. We argue that future legislation be further harmonized and state risk assessment as the gold standard for implementation of drug quality regulations for the preparation of unlicensed radiopharmaceuticals.


Assuntos
Guias de Prática Clínica como Assunto , Radioquímica/métodos , Compostos Radiofarmacêuticos , Controle Social Formal , Europa (Continente) , Humanos , Radioquímica/legislação & jurisprudência , Medição de Risco
4.
Med Phys ; 41(9): 092503, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25186412

RESUMO

PURPOSE: 90Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging 90Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for 90Y imaging and to optimize the PET protocol to improve the assessment and the quantification of 90Y-microsphere biodistribution after radioembolization. METHODS: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a 90Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with 90Y. To evaluate the count rate performance, 90Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml 90Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres®. The developed methodology was applied to ten patients after SIR-Spheres® treatment acquiring a 10 min per bed PET. RESULTS: The energy spectrum showed the 90Y bremsstrahlung radiation. The 90Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. 90Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the 90Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in 90Y PET acquisition, the optimal parameters for the standard OSEM+PSF reconstruction were only one iteration and a postreconstruction filter of 6 mm FWHM, for both TOF and non-TOF reconstructions. Moreover, when TOF is included, the signal to noise ratio increased and visibility achieved 100% by the experienced observers and 93.3% according to the Rose model of statistical detection. In 50% of patients, TOF allowed the visualization of 90Y radioembolized lesions not seen without TOF, confirming phantom results. Liver activity was accurately quantified, with no significant differences between reconstructed and actual delivered activity to the whole-liver [mean relative difference (10.2±14.7)%]. CONCLUSIONS: Qualitative and quantitative 90Y PET imaging improved with the introduction of TOF in a PET/CT scanner, thereby allowing the visualization of microsphere deposition in lesions not visible in non-TOF images. This technique accurately quantifies the total activity delivered to the liver during radioembolization with (90)Y-microspheres and allows dose estimation.


Assuntos
Braquiterapia , Embolização Terapêutica , Microesferas , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Ítrio/farmacocinética , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/metabolismo , Adenocarcinoma/terapia , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/terapia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/metabolismo , Colangiocarcinoma/terapia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/terapia , Simulação por Computador , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/metabolismo , Neoplasias Esofágicas/terapia , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/metabolismo , Tumores Neuroendócrinos/terapia , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Doses de Radiação , Razão Sinal-Ruído , Distribuição Tecidual , Radioisótopos de Ítrio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA