RESUMO
BACKGROUND: Indocyanine green near-infrared fluorescence bowel perfusion assessment has shown its potential benefit in preventing anastomotic leakage. However, the surgeon's subjective visual interpretation of the fluorescence signal limits the validity and reproducibility of the technique. Therefore, this study aimed to identify objective quantified bowel perfusion patterns in patients undergoing colorectal surgery using a standardized imaging protocol. METHOD: A standardized fluorescence video was recorded. Postoperatively, the fluorescence videos were quantified by drawing contiguous region of interests (ROIs) on the bowel. For each ROI, a time-intensity curve was plotted from which perfusion parameters (n = 10) were derived and analyzed. Furthermore, the inter-observer agreement of the surgeon's subjective interpretation of the fluorescence signal was assessed. RESULTS: Twenty patients who underwent colorectal surgery were included in the study. Based on the quantified time-intensity curves, three different perfusion patterns were identified. Similar for both the ileum and colon, perfusion pattern 1 had a steep inflow that reached its peak fluorescence intensity rapidly, followed by a steep outflow. Perfusion pattern 2 had a relatively flat outflow slope immediately followed by its plateau phase. Perfusion pattern 3 only reached its peak fluorescence intensity after 3 min with a slow inflow gradient preceding it. The inter-observer agreement was poor-moderate (Intraclass Correlation Coefficient (ICC): 0.378, 95% CI 0.210-0.579). CONCLUSION: This study showed that quantification of bowel perfusion is a feasible method to differentiate between different perfusion patterns. In addition, the poor-moderate inter-observer agreement of the subjective interpretation of the fluorescence signal between surgeons emphasizes the need for objective quantification.
Assuntos
Neoplasias Colorretais , Cirurgia Colorretal , Humanos , Verde de Indocianina , Neoplasias Colorretais/cirurgia , Anastomose Cirúrgica/métodos , Cirurgia Colorretal/métodos , Reprodutibilidade dos Testes , Fístula Anastomótica/prevenção & controle , PerfusãoRESUMO
PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.
Assuntos
Carcinoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Corantes Fluorescentes/administração & dosagem , Imagem Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Carcinoma/patologia , Carcinoma/terapia , Quimiorradioterapia Adjuvante , Colectomia/métodos , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/patologia , Neoplasias do Colo/terapia , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Integrinas/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/efeitos adversos , Peptídeos Cíclicos/administração & dosagem , Peptídeos Cíclicos/efeitos adversos , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacocinética , Compostos de Amônio Quaternário/administração & dosagem , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacocinética , Ratos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/administração & dosagem , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/farmacocinética , Testes de Toxicidade AgudaRESUMO
Lymph node dissection plays an important role in staging and treatment of solid cancers. Sentinel node biopsy (SNB) has been introduced to minimize the extent of surgery and to enable assessment of minimal residual disease (MRD) without compromising accurate staging or survival. This review addresses the variation in technical aspects and outcome of SNB and MRD assessment in patients with breast and gastrointestinal cancer. Quality control leading to standardization of SNB and pathological examination will enable reliable comparison of studies, which is necessary for consensus of diagnostic and therapeutic strategies.