Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Abdom Radiol (NY) ; 45(2): 437-448, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31686180

RESUMO

PURPOSE: To evaluate whether a structured radiology report improves the completeness of preoperative CT staging of pancreatic ductal adenocarcinoma (PDA) compared to conventional free-text reports. METHODS: We retrospectively included 27 patients (mean age, 64 ± 11.1 years) referred for pancreatic preoperative CT scan for staging of PDA between 2015 and 2018 and in whom a diagnosis of pancreatic adenocarcinoma was ultimately confirmed. Four readers independently reported CT scans with both conventional free-text and structured reports. Differences in reported morphologic and vascular features with the two reports were assessed through McNemar Test. Intra-reader and inter-reader were calculated. RESULTS: A total of 216 reports were completed by four different readers including 108 free-text and 108 structured reports. Overall, 139 of 540 morphologic characteristics of PDA and 869 of 1188 vascular key features were only described in structured reports. Encasement of left gastric artery, gastroduodenal artery and splenic artery was described in up to 14.8% using free-text reports and in up to 29.6% using structured report, resulting in low-intra-reader agreement (k = 0.033-0.216). Inter-reader agreement improved with structured report compared to free-text one for left gastric artery (ICC = 0.844 vs. ICC = 0.493, respectively), gastroduodenal artery (ICC = 0.730 vs. ICC = 0.449, respectively), portal vein (ICC = 0.847 vs. ICC = 0.638, respectively), portal confluence (ICC = 0.848 vs. ICC = 0.422, respectively) superior mesenteric vein (ICC = 0.765 vs. ICC = 0.695, respectively), and splenic vein (ICC = 0.921 vs. ICC = 0.841, respectively). CONCLUSION: Structured reports for PDA staging significantly reduces the number of missing morphological and vascular features of PDA and improves the inter-reader agreement compared to free-text reports.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma/patologia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pancreáticas/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Rev Argent Microbiol ; 48(2): 122-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27291283

RESUMO

Blinded rechecking is a method proposed for external quality assurance (EQA) of auramine-stained acid-fast bacilli (AFB) smears using fluorescence microscopy (FM), however, this procedure is not well developed and slides fading over time could compromise its implementation. Since bleaching of fluorescent molecules involves temperature-dependent chemical reactions, it is likely that low temperatures could slow down this process. We stored auramine-stained slides under different environmental conditions, including -20°C, and examined them over time. The slides stored in all the environments faded. At -20°C, fading was not reduced in relation to room temperature. Restaining and re-examining smears after five months showed that the slides containing saliva and storage at -20°C were associated with failure in AFB reappearance. In conclusion, the practice of freezing slides until they are viewed should be discouraged as it has a negative effect on blinded rechecking by reducing reading concordance after restaining. Specimen quality should be considered when interpreting FM-EQA results.


Assuntos
Benzofenoneídio/efeitos da radiação , Corantes Fluorescentes/efeitos da radiação , Microscopia de Fluorescência/métodos , Fotodegradação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Escarro/microbiologia , Coloração e Rotulagem/métodos , Tuberculose/diagnóstico , Argentina , Benzofenoneídio/análise , Criopreservação , Estudos de Viabilidade , Corantes Fluorescentes/análise , Humanos , Iluminação , Microscopia de Fluorescência/instrumentação , Variações Dependentes do Observador , Valor Preditivo dos Testes , Preservação Biológica/métodos , Reprodutibilidade dos Testes , Método Simples-Cego , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA