Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Xenobiotica ; 43(10): 862-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23451885

RESUMO

1. Ginkgo biloba extract (GBE) is one of the most commonly used herbal remedies worldwide. It is usually concomitantly administrated with statins to treat diseases in geriatric patients. We aim to determine the influence of GBE on the pharmacokinetics (PK) and pharmacodynamics of simvastatin, which is currently unknown. 2. An open-label, randomized, two-period, two-treatment, balanced, crossover study was performed in 14 healthy volunteers. Subjects received simvastatin 40 mg once daily, co-treated with placebo or GBE 120 mg twice daily. Each treatment was administered for 14 d, separated by a wash-out period of 1 month. Simvastatin, simvastatin acid and lipoprotein concentrations were assessed. 3. GBE administration reduced mean simvastatin area under the curve (AUC)0-24, AUC0-∞ and Cmax by 39% (p = 0.000), 36%(p = 0.001) and 32% (p = 0.002), respectively, but did not cause significant differences in simvastatin acid PK or its cholesterol-lowering efficacy. 4. GBE consumption decreased simvastatin system exposure, but did not affect simvastatin acid PK. However, we cannot rule out the possibility for a pharmacodynamic interaction between GBE and simvastatin in vivo.


Assuntos
Interações Ervas-Drogas , Extratos Vegetais/farmacocinética , Sinvastatina/farmacocinética , Adulto , Anticolesterolemiantes/farmacocinética , Voluntários Saudáveis , Humanos , Masculino , Sinvastatina/análogos & derivados , Sinvastatina/sangue , Adulto Jovem
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(21): 2000-4, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21680260

RESUMO

A simple and accurate high-performance liquid chromatography with diode array detection-based (HPLC-DAD) method has been developed and validated for simultaneous determination of amoxicillin and sulbactam in human plasma. Sample preparation was involved in protein precipitation with acetonitrile followed by one-step extraction procedure. Chromatographic separation was achieved on a C18 column with an isocratic mobile phase consisting of water (containing 30 mM potassium dihydrogen phosphate, pH 2.8) and acetonitrile. The detection wavelengths of a diode array detector were set at 210 nm for amoxicillin and sulbactam, and 263 nm for the internal standard (cefadroxil). The method was validated for linearity, accuracy, precision, and stability. The calibration curve was linear from 0.163 to 14.7 µg/mL with correlation coefficient squared of 0.9991 for amoxicillin and 0.250-15.0 µg/mL with correlation coefficient squared of 0.9988 for sulbactam using 500 µL plasma samples. The lower limit of quantification was 0.163 and 0.250 µg/mL for amoxicillin and sulbactam, respectively. The imprecisions of intra- and inter-day validations for amoxicillin and sulbactam were <11% and their accuracies (%) were within the range of 95.4-105.7%. Mean recoveries were 75.9, 72.8, and 70.0% for amoxicillin, sulbactam, and cefadroxil, respectively. The established method was successfully applied to a bioequivalence study of two combination formulations of amoxicillin and sulbactam pivoxil in healthy male volunteers.


Assuntos
Amoxicilina/sangue , Amoxicilina/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Sulbactam/sangue , Sulbactam/farmacocinética , Combinação de Medicamentos , Estabilidade de Medicamentos , Humanos , Análise dos Mínimos Quadrados , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Equivalência Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA