Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Neuroradiol ; 33(4): 1075-1086, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37368089

RESUMO

PURPOSE: Information about the cost-effectiveness of a certain treatment is relevant for decision-making and healthcare providers. This study compares the cost-effectiveness of the novel Woven Endobridge (WEB) for intracranial aneurysm treatment with conventional coiling and stent-assisted coiling (SAC) from the perspective of the German Statutory Health Insurance. METHODS: A patient-level simulation was constructed to simulate 55-year-old patients with an unruptured middle cerebral artery aneurysm (size: 3-11 mm) considering WEB treatment, coiling or SAC in terms of morbidity, angiographic outcome, retreatment, procedural and rehabilitation costs and rupture rates. Incremental cost-effectiveness ratios (ICERs) were calculated as costs per quality-adjusted life years (QALYs) and costs per year with neurologic morbidity avoided. Uncertainty was explored with deterministic and probabilistic sensitivity analyses. The majority of data were obtained from prospective multi-center studies and meta-analyses of non-randomized studies. RESULTS: In the base case, lifetime QALYs were 13.24 for the WEB, 12.92 for SAC and 12.68 for coiling. Lifetime costs were 20,440 € for the WEB, 23,167 € for SAC, and 8200 € for coiling. Compared to coiling, the ICER for the WEB was 21,826 €/QALY, while SAC was absolutely dominated by WEB. Probabilistic sensitivity analysis revealed that at a willingness-to-pay of ≥ 30,000 €/QALY, WEB was the preferred treatment. Deterministic sampling showed that the discount rate, material costs and retreatment rates had the largest impact on the ICERs. CONCLUSION: The novel WEB showed at least comparable cost-effectiveness to SAC for treatment of broad-based unruptured aneurysms. Considering all three modalities, coiling had the least costs; however this modality is often not appropriate for the treatment of wide-necked aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Pessoa de Meia-Idade , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Análise Custo-Benefício , Estudos Prospectivos , Resultado do Tratamento , Stents , Estudos Retrospectivos
2.
Quant Imaging Med Surg ; 12(7): 3640-3654, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35782261

RESUMO

Background: In stroke magnetic resonance imaging (MRI), contrast-enhanced magnetic resonance angiography (CE-MRA) is the clinical standard to depict extracranial arteries but native MRA techniques are of increased interest to facilitate clinical practice. The purpose of this study was to assess the detection of extracranial internal carotid artery (ICA) stenosis and plaques as well as the image quality of cervical carotid arteries between a novel flow-independent relaxation-enhanced angiography without contrast and triggering (REACT) sequence and CE-MRA in acute ischemic stroke (AIS). Methods: In this retrospective, single-center study, 105 consecutive patients (65.27±18.74 years, 63 males) were included, who received a standard stroke protocol at 3T in clinical routine including Compressed SENSE (CS) accelerated (factor 4) 3D isotropic REACT (fixed scan time: 02:46 min) and CS accelerated (factor 6) 3D isotropic CE-MRA. Three radiologists independently assessed scans for the presence of extracranial ICA stenosis and plaques (including hyper-/hypointense signal) with concomitant diagnostic confidence using 3-point scales (3= excellent). Vessel quality, artifacts, and image noise of extracranial carotid arteries were subjectively scored on 5-point scales (5= excellent/none). Wilcoxon tests were used for statistical comparison. Results: Considering CE-MRA as the standard of reference, REACT provided a sensitivity of 89.8% and specificity of 95.2% for any and of 93.5% and 95.8% for clinically relevant (≥50%) extracranial ICA stenosis and yielded a to CE-MRA comparable diagnostic confidence [mean ± standard deviation (SD), median (interquartile range): 2.8±0.5, 3 (3-3) vs. 2.7±0.5, 3 (2-3), P=0.03]. Using REACT, readers detected more plaques overall (n=57.3 vs. 47.7, P<0.001) and plaques of hyperintense signal (n=12.3 vs. 5.7, P=0.02) with higher diagnostic confidence [2.8±0.5, 3 (3-3) vs. 2.6±0.7, 3 (2-3), P<0.001] than CE-MRA. After analyzing a total of 1,260 segments, the vessel quality of all segments combined [4.61±0.66 vs. 4.58±0.68, 5 (4-5) vs. 5 (4-5), P=0.0299] and artifacts [4.51±0.70 vs. 4.44±0.73, 5 (4-5) vs. 5 (4-5), P>0.05] were comparable between the sequences with REACT showing a lower image noise [4.43±0.67 vs. 4.25±0.71, 5 (4-5) vs. 4 (4-5), P<0.001]. Conclusions: Without the use of gadolinium-based contrast agents or triggering, REACT provides a high sensitivity and specificity for extracranial ICA stenosis and a potential improved depiction of adjacent plaques while yielding to CE-MRA comparable vessel quality in a large patient cohort with AIS.

3.
Diagnostics (Basel) ; 12(6)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35741116

RESUMO

BACKGROUND: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. METHODS: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40-120 keV). Additionally, two radiologists rated the perceived image quality. RESULTS: The mean CTDIvol used in the PCCT was 8.31 ± 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60-65 keV was rated as best image quality. CONCLUSION: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA