Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; 11(13): e2307609, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38279514

RESUMO

Noncommunicable diseases (NCD), such as obesity, diabetes, and cardiovascular disease, are defining healthcare challenges of the 21st century. Medical infrastructure, which for decades sought to reduce the incidence and severity of communicable diseases, has proven insufficient in meeting the intensive, long-term monitoring needs of many NCD disease patient groups. In addition, existing portable devices with rigid electronics are still limited in clinical use due to unreliable data, limited functionality, and lack of continuous measurement ability. Here, a wearable system for at-home cardiovascular monitoring of postpartum women-a group with urgently unmet NCD needs in the United States-using a cloud-integrated soft sternal device with conformal nanomembrane sensors is introduced. A supporting mobile application provides device data to a custom cloud architecture for real-time waveform analytics, including medical device-grade blood pressure prediction via deep learning, and shares the results with both patient and clinician to complete a robust and highly scalable remote monitoring ecosystem. Validated in a month-long clinical study with 20 postpartum Black women, the system demonstrates its ability to remotely monitor existing disease progression, stratify patient risk, and augment clinical decision-making by informing interventions for groups whose healthcare needs otherwise remain unmet in standard clinical practice.


Assuntos
Aplicativos Móveis , Doenças não Transmissíveis , Dispositivos Eletrônicos Vestíveis , Feminino , Humanos , Monitorização Fisiológica
2.
Artigo em Inglês | MEDLINE | ID: mdl-31217100

RESUMO

This article evaluated the repeatability and reproducibility (R&R) of quantitative ultrasound (QUS) biomarkers attenuation coefficient (AC) and backscatter coefficient (BSC) in transvaginal QUS reference phantoms for obstetric applications. Five phantoms were scanned by three sonographers according to the scanning protocol. Each sonographer scanned each phantom with four transvaginal transducers of the same model (MC9-4) and three probe cover types (latex cover, nonlatex cover, and no cover). The AC and BSC were estimated by using a reference phantom method. The R&R analysis was performed for the frequency-averaged AC and logBSC (= 10log10BSC) (5.4-5.8 MHz) by using three-factor random effects Analysis of Variance with interaction. The total R&R variabilities for AC and logBSC are small (AC: 0.042-0.065 dB/cm-MHz; logBSC: 0.50-0.68 dB), indicating high measurement precision. These values are small compared to the ranges of AC (0.28-0.99 dB/cm-MHz) and logBSC (-33.16 to -20.35 dB) of the five phantoms. The AC and logBSC biomarkers measured on transvaginal QUS phantoms using the reference phantom method are repeatable, and reproducible between sonographers, transducers, and probe covers.


Assuntos
Ultrassonografia/métodos , Vagina , Feminino , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA