Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Vasc Surg ; 35(2): 286-91, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11854726

RESUMO

PURPOSE: The purpose of this study was the assessment of the safety, efficacy, and hospital charges of bedside duplex ultrasound-directed inferior vena cava (IVC) filter placement. METHODS: All duplex ultrasound-directed IVC filters that were placed from August 8, 1995, to December 31, 2000, are reviewed. Chart review combined with mailed questionnaires and telephone follow-up examinations were used to collect demographic and outcome data. RESULTS: Three hundred twenty-five patients underwent evaluation, and 284 underwent duplex ultrasound-directed IVC filter placement. Two hundred three (71%) were male patients, and 81 (29%) were female patients. Poor IVC visualization, IVC thrombosis, and unsuitable anatomy prevented duplex-directed filter placement in 41 patients (12%). Indication for filter placement included venous prophylaxis in the absence of thromboembolism in 235 patients (83%), contraindication to anticoagulation therapy in 34 patients (12%), prophylaxis with therapeutic anticoagulation therapy in the presence of thromboembolism in 7 patients (2%), and complication of anticoagulation therapy in 8 patients (3%). There were no procedure-related deaths or septic complications. Technical complications occurred in 12 patients (4%). Filter misplacement occurred in 6 patients (2%), access thrombosis in 1 (<1%), migration in 1 (<1%), bleeding in 1 (<1%), and IVC occlusion in 3 (1%). Pulmonary emboli after IVC filter placement occurred in one patient with a misplaced filter. Average hospital charges related to duplex ultrasound-directed filter placement were $2388 less than fluoroscopic placement charges in the year 2000. CONCLUSION: Our experience indicates that duplex ultrasound-directed IVC filter placement is safe, cost-effective, and convenient for patients who need IVC filter placement.


Assuntos
Ultrassonografia Doppler Dupla/instrumentação , Filtros de Veia Cava , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular/economia , Segurança de Equipamentos , Feminino , Veia Femoral/diagnóstico por imagem , Veia Femoral/patologia , Seguimentos , Custos de Cuidados de Saúde , Humanos , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Embolia Pulmonar/prevenção & controle , Análise de Sobrevida , Tennessee/epidemiologia , Resultado do Tratamento , Ultrassonografia Doppler Dupla/economia , Filtros de Veia Cava/economia , Filtros de Veia Cava/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA