Card Electrophysiol Clin ; 13(3): 531-542, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34330379

RESUMO

Atrial fibrillation (AF) is associated with adverse outcomes. Screening may lead to earlier recognition and treatment of asymptomatic AF. However, most evidence regarding AF applies to clinical AF, with symptoms or electrocardiographic diagnosis. Whether this evidence can be translated toward subclinical AF, without symptoms and detected by novel, more continuous screening devices is uncertain. The diagnostic yield of screening is determined by the screening population, tool, duration and frequency. Longer and more frequent screening in a higher risk population leads to more effective screening. New devices based on photoplethysmography and single-lead electrocardiography increase convenience and the likelihood of cost-effectiveness.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Análise Custo-Benefício , Eletrocardiografia , Humanos , Programas de Rastreamento , Fatores de Risco
2.
Clin Cardiol ; 43(11): 1232-1239, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33030259

RESUMO

BACKGROUND: Although novel teleconsultation solutions can deliver remote situations that are relatively similar to face-to-face interaction, remote assessment of heart rate and rhythm as well as risk factors remains challenging in patients with atrial fibrillation (AF). HYPOTHESIS: Mobile health (mHealth) solutions can support remote AF management. METHODS: Herein, we discuss available mHealth tools and strategies on how to incorporate the remote assessment of heart rate, rhythm and risk factors to allow comprehensive AF management through teleconsultation. RESULTS: Particularly, in the light of the coronavirus disease 2019 (COVID-19) pandemic, there is decreased capacity to see patients in the outpatient clinic and mHealth has become an important component of many AF outpatient clinics. Several validated mHealth solutions are available for remote heart rate and rhythm monitoring as well as for risk factor assessment. mHealth technologies can be used for (semi-)continuous longitudinal monitoring or for short-term on-demand monitoring, dependent on the respective requirements and clinical scenarios. As a possible solution to improve remote AF care through teleconsultation, we introduce the on-demand TeleCheck-AF mHealth approach that allows remote app-based assessment of heart rate and rhythm around teleconsultations, which has been developed and implemented during the COVID-19 pandemic in Europe. CONCLUSION: Large scale international mHealth projects, such as TeleCheck-AF, will provide insight into the additional value and potential limitations of mHealth strategies to remotely manage AF patients. Such mHealth infrastructures may be well suited within an integrated AF-clinic, which may require redesign of practice and reform of health care systems.


Assuntos
Fibrilação Atrial/terapia , Betacoronavirus , Infecções por Coronavirus/epidemiologia , Controle de Infecções/organização & administração , Pneumonia Viral/epidemiologia , Consulta Remota/organização & administração , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , SARS-CoV-2
3.
Trials ; 20(1): 370, 2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31221218

RESUMO

BACKGROUND: Success rates with conventional transvenous endocardial pulmonary vein isolation in patients with persistent and longstanding persistent atrial fibrillation (AF) are variable due to advanced electrical and structural remodeling of the atria. As a consequence, more extensive endocardial lesions, minimally invasive thoracoscopic surgical techniques, and hybrid ablation (combining thoracoscopic epicardial surgical and endocardial catheter ablation) have been developed. HYPOTHESIS: The HARTCAP-AF trial hypothesizes that hybrid AF ablation is more effective than (repeated) transvenous endocardial catheter ablation in (longstanding) persistent AF, without increasing the number of associated major adverse events. METHODS: This randomized controlled trial will include 40 patients with persistent or longstanding persistent AF who will be 1:1 randomized to either hybrid ablation or (repeated) catheter ablation. The procedures and follow-up are conducted according to the guidelines. The primary effectiveness endpoint is freedom from any supraventricular arrhythmia lasting longer than 5 min without the use of Vaughan-Williams class I or III antiarrhythmic drugs through 12 months of follow-up after the last procedure. In the catheter ablation arm, a second procedure planned within 6 months after the index procedure is allowed for obtaining the primary endpoint. Additionally, adverse events, cost-effectiveness, and quality of life data will be recorded. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02441738 . Registered on 12 May 2015.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Toracoscopia/métodos , Fibrilação Atrial/psicologia , Análise Custo-Benefício , Humanos , Qualidade de Vida
4.
Europace ; 20(suppl_3): iii113-iii119, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476061

RESUMO

AIMS: Diagnosing long QT syndrome (LQTS) is challenging due to a considerable overlap of the QTc-interval between LQTS patients and healthy controls. The aim of this study was to investigate the added value of T-wave morphology markers obtained from 12-lead electrocardiograms (ECGs) in diagnosing LQTS in a large cohort of gene-positive LQTS patients and gene-negative family members using a support vector machine. METHODS AND RESULTS: A retrospective study was performed including 688 digital 12-lead ECGs recorded from genotype-positive LQTS patients and genotype-negative relatives at their first visit. Two models were trained and tested equally: a baseline model with age, gender, RR-interval, QT-interval, and QTc-intervals as inputs and an extended model including morphology features as well. The best performing baseline model showed an area under the receiver-operating characteristic curve (AUC) of 0.821, whereas the extended model showed an AUC of 0.901. Sensitivity and specificity at the maximal Youden's indexes changed from 0.694 and 0.829 with the baseline model to 0.820 and 0.861 with the extended model. Compared with clinically used QTc-interval cut-off values (>480 ms), the extended model showed a major drop in false negative classifications of LQTS patients. CONCLUSION: The support vector machine-based extended model with T-wave morphology markers resulted in a major rise in sensitivity and specificity at the maximal Youden's index. From this, it can be concluded that T-wave morphology assessment has an added value in the diagnosis of LQTS.


Assuntos
Potenciais de Ação , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Síndrome do QT Longo/diagnóstico , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte , Predisposição Genética para Doença , Humanos , Síndrome do QT Longo/genética , Síndrome do QT Longo/fisiopatologia , Fenótipo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
5.
Eur Heart J ; 28(3): 345-53, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17242015

RESUMO

AIMS: Spontaneous or inducible sustained ventricular arrhythmias (VA) in endurance athletes frequently originate from the right ventricle (RV), even in the absence of familial arrhythmogenic RV cardiomyopathy (ARVC). The goal of this study was to determine whether the RV arrhythmogenic predilection in these patients is associated with RV functional abnormalities. METHODS AND RESULTS: Biplane RV angiography was performed in three groups: 22 endurance athletes with VA, 15 matched athletes without VA, and 10 non-athletes without VA. Four methods for quantitative RV angiographic analysis (area length, Boak, pyramid monoplane, and pyramid biplane) were used to calculate RV end-diastolic volume (EDV) and end-systolic volume (ESV) (both corrected for body surface area) and ejection fraction (EF). In addition RV outflow tract shortening fraction (SF) was determined. Although only 6 of 22 (27%) athletes with VA fulfilled the diagnostic criteria for ARVC, RV arrhythmogenic involvement was manifest or probable in 82%, based on a combination of electrophysiologic, electrocardiographic, and morphologic criteria. RV EDV in athletes was higher than in non-athletes (area length: 100.3 +/- 26.9 vs. 69.6 +/- 14.3 mL/m(2), P = 0.001), without significant difference between athletes with and without VA. RV ESV, in contrast, was significantly higher in athletes with VA than in athletes without VA (52.6 +/- 22.3 vs. 35.5 +/- 11.2 mL/m(2), P = 0.004), resulting in a significantly lower RV EF, a consistent finding across all methods (area length: 49.1 +/- 10.4 vs. 63.7 +/- 6.4%, P < 0.001). This functional impairment was also reflected in a lower RV outflow tract SF (SF right anterior oblique 32.2 +/- 10.1 vs. 40.0 +/- 11.6%, P = 0.09; SF left anterior oblique (LAO) 31.9 +/- 7.8 vs. 39.0 +/- 10.5%, P = 0.10). CONCLUSION: VA in high-level endurance athletes frequently originate from a mildly dysfunctional RV. This raises the question whether endurance exercise not only acts as a trigger for these arrhythmias but also as promoter of the RV changes.


Assuntos
Arritmias Cardíacas/fisiopatologia , Esportes , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico por imagem , Estudos de Casos e Controles , Angiografia Coronária , Ecocardiografia , Exercício Físico/fisiologia , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/diagnóstico por imagem