Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Haemophilia ; 27(6): e713-e720, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34455654

RESUMO

BACKGROUND: Laboratory diagnosis of von Willebrand Disease (VWD) is complex. Reliance on laboratory testing can be problematic as different VWD screening panels, assays and methodologies can produce analytic variability in test results. OBJECTIVES: To compare the degree of imprecision among the VWD assays and within the platelet binding activity (PBA) assays, to determine the consensus among the VWD assays for correct classification of sample results, and to determine consensus among laboratories' von Willebrand factor (VWF) multimer interpretations and final interpretations of the VWD panels. PATIENTS/METHODS: Proficiency testing results from the North American Specialized Coagulation Laboratory Association (NASCOLA) submitted by laboratories from 2010 to 2019 for all normal, type (T) 1 VWD and T2 VWD samples were analysed. RESULTS AND CONCLUSIONS: Imprecision was lowest for VWF antigen and highest for collagen binding activity (CBA) with median coefficient of variation (CV) of 12% (interquartile range (IQR) 7%) and 23% (IQR 21%) respectively. Within the VWF PBA assays, the gain-of-function mutant GP1b binding (VWF: GP1bM) methods had the least imprecision (CV 9%, IQR 10%). All assays, including the various PBA methods had excellent consensus. The majority of laboratories agreed that normal (median consensus-82%, IQR 16%) and T1 VWD (median consensus-100%, IQR 9%) samples had normal multimer distribution. Consensus among laboratories for final interpretations was excellent for normal samples (median 81%, IQR 8%), good for T1 VWD samples (median 59%, IQR 9%), and fair for T2 VWD samples (median 44%, IQR 21%). Consensus on final interpretation decreased as sample complexity increased.


Assuntos
Doenças de von Willebrand , Testes de Coagulação Sanguínea , Humanos , Laboratórios , América do Norte , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand
2.
Semin Thromb Hemost ; 38(6): 622-31, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22718255

RESUMO

The quality of platelet aggregation and dense granule deficiency testing is important for diagnosing platelet function disorders. After a successful pilot exercise on diagnosing platelet dense granule deficiency by electron microscopy (EM), the North American Specialized Coagulation Laboratory Association (NASCOLA) has launched regular external quality assurance (EQA) for dense granule EM, as well as for the interpretation of platelet aggregation findings. EQA records were analyzed to assess performance. For EM EQA, between 2009 and 2011, there was excellent performance in distinguishing normal from dense granule-deficient samples and good (>70%) agreement on classifying most electron dense structures in platelets. For aggregation EQA, some normal variants were misclassified and overall case interpretations were more acceptable for rare disorders than for common findings. NASCOLA experiences with these EQAs indicate that there is a need to improve the quality of platelet disorder evaluations. For aggregometry interpretations, deficits in performance could be addressed by translating guideline recommendations into practice.


Assuntos
Transtornos Plaquetários/sangue , Transtornos Plaquetários/diagnóstico , Plaquetas/patologia , Grânulos Citoplasmáticos/patologia , Testes de Função Plaquetária/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Plaquetas/ultraestrutura , Grânulos Citoplasmáticos/ultraestrutura , Coleta de Dados , Humanos , Microscopia Eletrônica , Agregação Plaquetária/fisiologia , Testes de Função Plaquetária/normas , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA