Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Europace ; 25(3): 835-844, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36748247

RESUMO

AIMS: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. METHODS AND RESULTS: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). CONCLUSION: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Fotopletismografia/métodos , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial , Algoritmos
2.
Int J Cardiol ; 367: 29-37, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35963443

RESUMO

BACKGROUND: The assessment of symptom-rhythm correlation (SRC) in patients with persistent atrial fibrillation (AF) is challenging. Therefore, we performed a novel mobile app-based approach to assess SRC in persistent AF. METHODS: Consecutive persistent AF patients planned for electrical cardioversion (ECV) used a mobile app to record a 60-s photoplethysmogram (PPG) and report symptoms once daily and in case of symptoms for four weeks prior and three weeks after ECV. Within each patient, SRC was quantified by the SRC-index defined as the sum of symptomatic AF recordings and asymptomatic non-AF recordings divided by the sum of all recordings. RESULTS: Of 88 patients (33% women, age 68 ± 9 years) included, 78% reported any symptoms during recordings. The overall SRC-index was 0.61 (0.44-0.79). The study population was divided into SRC-index tertiles: low (<0.47), medium (0.47-0.73) and high (≥0.73). Patients within the low (vs high) SRC-index tertile had more often heart failure and diabetes mellitus (both 24.1% vs 6.9%). Extrasystoles occurred in 19% of all symptomatic non-AF PPG recordings. Within each patient, PPG recordings with the highest (vs lowest) tertile of pulse rates conferred an increased risk for symptomatic AF recordings (odds ratio [OR] 1.26, 95% coincidence interval [CI] 1.04-1.52) and symptomatic non-AF recordings (OR 2.93, 95% CI 2.16-3.97). Pulse variability was not associated with reported symptoms. CONCLUSIONS: In patients with persistent AF, SRC is relatively low. Pulse rate is the main determinant of reported symptoms. Further studies are required to verify whether integrating mobile app-based SRC assessment in current workflows can improve AF management.


Assuntos
Fibrilação Atrial , Aplicativos Móveis , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Cardioversão Elétrica , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
3.
Int J Cardiol Heart Vasc ; 42: 101086, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35873859

RESUMO

Atrial fibrillation (AF) is the most common sustained heart rhythm disorder and is often associated with symptoms that can significantly impact quality of life and daily functioning. Palpitations are the cardinal symptom of AF and many AF therapies are targeted towards relieving this symptom. However, up to two-third of patients also complain of dyspnea as a predominant self-reported symptom. In clinical practice it is often challenging to ascertain whether dyspnea represents an AF-related symptom or a symptom of concomitant cardiovascular and non-cardiovascular comorbidities, since common AF comorbidities such as heart failure and chronic obstructive pulmonary disease share similar symptoms. In addition, therapeutic approaches specifically targeting dyspnea have not been well validated. Thus, assessing and treating dyspnea can be difficult. This review describes the latest knowledge on the burden and pathophysiology of dyspnea in AF patients. We discuss the role of heart rhythm control interventions as well as the management of AF risk factors and comorbidities with the goal to achieve maximal relief of dyspnea. Given the different and often complex mechanistic pathways leading to dyspnea, dyspneic AF patients will likely profit from an integrated multidisciplinary approach to tackle all factors and mechanisms involved. Therefore, we propose an interdisciplinary and integrated care pathway for the work-up of dyspnea in AF patients.

4.
Cardiology ; 146(3): 392-396, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33735889

RESUMO

Recently, we introduced the TeleCheck-AF approach, an on-demand mobile health (mHealth) infrastructure using app-based heart rate and rhythm monitoring for 7 days, to support long-term atrial fibrillation (AF) management through teleconsultation. Herein, we extend the mHealth approach to patients with recent-onset AF at the emergency department (ED). In the proposed TeleWAS-AF approach, on-demand heart rate and rhythm monitoring are used to support a wait-and-see strategy at the ED. All stable patients who present to the ED with recent-onset symptomatic AF and who are able to use mHealth solutions for heart rate and rhythm monitoring are eligible for this approach. Patients will receive both education on AF and instructions on the use of the mHealth technology before discharge from the ED. A case coordinator will subsequently check whether patients are able to activate the mHealth solution and to perform heart rate and rhythm measurements. Forty hours after AF onset, the first assessment teleconsultation with the physician will take place, determining the need for delayed cardioversion. After maximal 7 days of remote monitoring, a second assessment teleconsultation may occur, in which the rhythm can be reassessed and further treatment strategy can be discussed with the patients. This on-demand mHealth prescription increases patient involvement in the care process and treatment decision-making by encouraging self-management, while avoiding excess data-load requiring work-intensive and expensive data management. Implementation of the TeleWAS-AF approach may facilitate the management of AF in the ED and reduce the burden on the ED system, which enhances the capacity for health care utilization.


Assuntos
Fibrilação Atrial , Telemedicina , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Serviço Hospitalar de Emergência , Frequência Cardíaca , Humanos
5.
Front Cardiovasc Med ; 8: 757587, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35127847

RESUMO

INTRODUCTION: The TeleCheck-AF approach is an on-demand mobile health (mHealth) infrastructure incorporating mobile app-based heart rate and rhythm monitoring through teleconsultation. We evaluated feasibility and accuracy of self-reported mHealth-based AF risk factors and CHA2DS2-VASc-score in atrial fibrillation (AF) patients managed within this approach. MATERIALS AND METHODS: Consecutive patients from eight international TeleCheck-AF centers were asked to complete an app-based 10-item questionnaire related to risk factors, associated conditions and CHA2DS2-VASc-score components. Patient's medical history was retrieved from electronic health records (EHR). RESULTS: Among 994 patients, 954 (96%) patients (38% female, median age 65 years) completed the questionnaire and were included in this analysis. The accuracy of self-reported assessment was highest for pacemaker and anticoagulation treatment and lowest for heart failure and arrhythmias. Patients who knew that AF increases the stroke risk, more often had a 100% or ≥80% correlation between EHR- and app-based results compared to those who did not know (27 vs. 14% or 84 vs. 77%, P = 0.001). Thromboembolic events were more often reported in app (vs. EHR) in all countries, whereas higher self-reported hypertension and anticoagulant treatment were observed in Germany and heart failure in the Netherlands. If the app-based questionnaire alone was used for clinical decision-making on anticoagulation initiation, 26% of patients would have been undertreated and 6.1%-overtreated. CONCLUSION: Self-reported mHealth-based assessment of AF risk factors is feasible. It shows high accuracy of pacemaker and anticoagulation treatment, nevertheless, displays limited accuracy for some of the CHA2DS2-VASc-score components. Direct health care professional assessment of risk factors remains indispensable to ensure high quality clinical-decision making.

6.
Clin Cardiol ; 43(11): 1232-1239, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33030259

RESUMO

BACKGROUND: Although novel teleconsultation solutions can deliver remote situations that are relatively similar to face-to-face interaction, remote assessment of heart rate and rhythm as well as risk factors remains challenging in patients with atrial fibrillation (AF). HYPOTHESIS: Mobile health (mHealth) solutions can support remote AF management. METHODS: Herein, we discuss available mHealth tools and strategies on how to incorporate the remote assessment of heart rate, rhythm and risk factors to allow comprehensive AF management through teleconsultation. RESULTS: Particularly, in the light of the coronavirus disease 2019 (COVID-19) pandemic, there is decreased capacity to see patients in the outpatient clinic and mHealth has become an important component of many AF outpatient clinics. Several validated mHealth solutions are available for remote heart rate and rhythm monitoring as well as for risk factor assessment. mHealth technologies can be used for (semi-)continuous longitudinal monitoring or for short-term on-demand monitoring, dependent on the respective requirements and clinical scenarios. As a possible solution to improve remote AF care through teleconsultation, we introduce the on-demand TeleCheck-AF mHealth approach that allows remote app-based assessment of heart rate and rhythm around teleconsultations, which has been developed and implemented during the COVID-19 pandemic in Europe. CONCLUSION: Large scale international mHealth projects, such as TeleCheck-AF, will provide insight into the additional value and potential limitations of mHealth strategies to remotely manage AF patients. Such mHealth infrastructures may be well suited within an integrated AF-clinic, which may require redesign of practice and reform of health care systems.


Assuntos
Fibrilação Atrial/terapia , Betacoronavirus , Infecções por Coronavirus/epidemiologia , Controle de Infecções/organização & administração , Pneumonia Viral/epidemiologia , Consulta Remota/organização & administração , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA