Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 96(4): 878-888, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32294303

RESUMO

BACKGROUND: Polymer-based bioresorbable scaffolds (PBBS) have been assessed for coronary revascularization with mixed outcomes. Few studies have targeted pediatric-specific scaffolds. We sought to assess safety, efficacy, and short-term performance of a dedicated drug-free PBBS pediatric scaffold compared to a standard low-profile bare metal stent (BMS) in central and peripheral arteries of weaned piglets. METHODS: Forty-two devices (22 Elixir poly-L-lactic-acid-based pediatric bioresorbable scaffolds [BRS] [6 × 18 mm] and 20 control BMS Cook Formula 418 [6 × 20 mm]) were implanted in the descending aorta and pulmonary arteries (PAs) of 14 female Yucatan piglets. Quantitative measurements were collected on the day of device deployment and 30 and 90 days postimplantation to compare device patency and integrity. RESULTS: The BRS has a comparable safety profile to the BMS in the acute setting. Late lumen loss (LLL) and percent diameter stenosis (%DS) were not significantly different between BRS and BMS in the PA at 30 days. LLL and %DS were greater for BRS versus BMS in the aorta at 30 days postimplantation (LLL difference: 0.96 ± 0.26; %DS difference: 16.15 ± 4.51; p < .05). At 90 days, %DS in the aortic BRS was less, and PA BRS LLL was also less than BMS. Histomorphometric data showed greater intimal proliferation and area stenosis in the BRS at all time points and in all vessels. CONCLUSIONS: A dedicated PBBS pediatric BRS has a favorable safety profile in the acute/subacute setting and demonstrates characteristics that are consistent with adult BRSs.


Assuntos
Aorta Abdominal/patologia , Procedimentos Endovasculares/instrumentação , Metais , Poliésteres , Artéria Pulmonar/patologia , Stents , Angiografia , Animais , Animais Recém-Nascidos , Aorta Abdominal/diagnóstico por imagem , Proliferação de Células , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Teste de Materiais , Neointima , Desenho de Prótese , Artéria Pulmonar/diagnóstico por imagem , Suínos , Porco Miniatura , Fatores de Tempo , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA