Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Pers Med ; 14(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38541043

RESUMO

BACKGROUND: The investigation of soft tissue stiffness has garnered increasing interest due to its potential applications in detecting tissue conditions, monitoring therapy effects, and preventing sports injuries. This study utilized the MyotonPro as a reliable measurement device to assess muscle stiffness and muscle frequency in the vastus lateralis and medialis muscles of both the dominant and non-dominant legs. METHODS: Sixteen young, healthy subjects (seven males and nine females, age 25 ± 3.46 years) participated in this study. To induce maximal muscle fatigue, the vastus lateralis and vastus medialis muscles were subjected to a 30 kg load using a single-leg leg press. Pre- and post-fatigue measurements were conducted by two testers on the dominant and non-dominant legs, respectively, employing the MyotonPro. RESULTS: We revealed a significant increase in muscle stiffness after maximal muscle fatigue. Specifically, on the dominant side, the vastus lateralis exhibited a stiffness increase of 6.5%, while the vastus medialis showed a 6.3% increase. On the non-dominant side, the vastus lateralis demonstrated a 7.6% increase, and the vastus medialis exhibited a 6.7% increase in muscle stiffness. Furthermore, muscle frequency increased by 8.6% (vastus lateralis) and 13.5% (vastus medialis) on the dominant side and by 15.1% (vastus lateralis) and 6.3% (vastus medialis) on the non-dominant side. The reliability of the measurements varied, with Cronbach's alpha values ranging from inadequate 0.49 to very good 0.88. CONCLUSION: This study affirms the efficacy of the MyotonPro as a measurement device for assessing muscle stiffness and establishes its reliability. The observed increase in muscle stiffness after maximal muscle fatigue, accompanied by changes in muscle frequency, underscores the device's utility. However, further research is warranted to validate the reproducibility of these findings and explore additional facets of the muscular response to fatigue.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3854-3860, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36907938

RESUMO

PURPOSE: The purpose of this study was to summarise the current use of outcome measures for the assessment of physical function after knee joint replacement. METHODS: A systematic approach following the PRISMA guidelines was used. Literature search was performed on MEDLINE database via PubMed and on Epistemonikos. Clinical trials (level of evidence I-II) on knee joint replacement reporting data on the 'physical function' domain published between January 2017 and June 2022 were included. Descriptive statistics were used to summarise the evidence. RESULTS: In the 181 articles that met the inclusion criteria, 49 different outcome measurements were used to evaluate clinical outcomes after knee joint replacement. The most frequently adopted patient-reported outcome measures (PROMs) were the Knee Society Score (KSS) (78 studies; 43.1%), the Western Ontario and McMaster Universities (WOMAC) Arthritis Index (62 studies; 34.3%), the Oxford Knee Score (OKS) (51 studies; 28.2%) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) (36 studies; 20%). The most frequently used performance-based outcome measures (PBOMs) were the Timed-Up-and-Go (TUG) test (30 studies; 16.6%) and the 6-min-walk test (6MWT) (21 studies; 11.6%). Among impairment-based outcome measures (IBOMs), range of motion (ROM) was the most used (74 studies; 40.9%). CONCLUSION: There is considerable variation among clinical studies regarding the assessment of the physical function of patients after knee joint replacement. PROMs were found to be the most commonly adopted outcome measures; however, no single PROM was used in more than half of the papers analysed. LEVEL OF EVIDENCE: Level II, systematic review of level I-II studies.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Amplitude de Movimento Articular , Teste de Caminhada , Articulação do Joelho/cirurgia , Resultado do Tratamento
3.
BMC Health Serv Res ; 23(1): 193, 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36823581

RESUMO

BACKGROUND: The provision of low-value physiotherapy services in low back pain management is a known but complex phenomenon. Thus, this scoping review aims to systematically map existing research designs and instruments of the field in order to discuss the current state of research methodologies and contextualize results to domains and perspectives of a referred low-value care typology. Ultimately, results will be illustrated and transferred to conditions of the German health care setting as care delivery conditions of physiotherapy in Germany face unique particularities. METHODS: The development of this review is guided by the analysis framework of Arksey and O'Malley. A two-stage, audited search strategy was performed in Medline (PubMed), Web of Science, and google scholar. All types of observational studies were included. Identified articles needed to address a pre-determined population, concept, and context framework and had to be published in English or German language. The publication date of included articles was not subject to any limitation. The applied framework to assess the phenomenon of low-value physiotherapy services incorporated three domains (care effectiveness; care efficiency; patient alignment of care) and perspectives (provider; patient; society) of care. RESULTS: Thirty-three articles met the inclusion criteria. Seventy-nine percent of articles focused on the appropriateness of physiotherapeutic treatments, followed by education and information (30%), the diagnostic process (15%), and goal-setting practice (12%). Study designs were predominantly cross-sectional (58%). Data sources were mainly survey instruments (67%) of which 50% were self-developed. Most studies addressed the effectiveness domain of care (73%) and the provider perspective (88%). The perspective of patient alignment was assessed by 6% of included articles. None of included articles assessed the society perspective. Four methodical approaches of included articles were rated to be transferrable to Germany. CONCLUSION: Identified research on low-value physiotherapy care in low back pain management was widely unidimensional. Most articles focused on the effectiveness domain of care and investigated the provider perspective. Most measures were indirectly and did not monitor low-value care trends over a set period of time. Research on low-value physiotherapy care in secondary care conditions, such as Germany, was scarce. REGISTRATION: This review has been registered on open science framework ( https://osf.io/vzq7k https://doi.org/10.17605/OSF.IO/PMF2G ).


Assuntos
Dor Lombar , Humanos , Estudos Transversais , Dor Lombar/terapia , Cuidados de Baixo Valor , Projetos de Pesquisa , Modalidades de Fisioterapia
4.
Adv Clin Exp Med ; 32(2): 203-209, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36135819

RESUMO

BACKGROUND: Motion analysis systems have been widely used in orthopedics and rehabilitation for diagnostics, patient monitoring and outcome evaluation purposes. Since Microsoft Azure Kinect Developer Kit (DK) had been released, only a few studies were published concerning its usage. However, it has not been used for wrist motion assessments, even though the use of standardized examinations with known reliability, validity and responsiveness remains a constant challenge. OBJECTIVES: This study aimed to examine the reliability of hand and forearm range of motion (ROM) measurements recorded using new software utilizing the Microsoft Azure Kinect DK. MATERIAL AND METHODS: Twenty-eight healthy males and 28 healthy females participated in measurements of active ROM for wrist extension, wrist flexion, radial deviation, ulnar deviation, and forearm supination and pronation on 3 separate occasions. Sessions 1 and 2 were carried out on the same day with a 90-minute rest period between each session, while the 3rd session was conducted a week later. Data were recorded simultaneously in both limbs using a custom-made software developed by a software development company (Oleksy Medical & Sports Sciences, Lancut, Poland) for the purposes of the present study using Microsoft Azure Kinect DK. The assessment of intra-day and inter-day reliability was based on intraclass correlation coefficient (ICC) calculations and interpreted based on commonly used guidelines. RESULTS: In the group of males, the lowest ICC was 0.846 for intra-day comparisons and 0.816 for inter-day analyses. In the female group, the lowest ICC for intra-day comparisons was 0.826 and exceeded 0.833 for inter-day comparisons. CONCLUSIONS: The developed software using Microsoft Azure Kinect DK demonstrated high reliability in measuring wrist and forearm active ROM. These promising results support the use of Microsoft Azure Kinect DK in a clinical capacity as a potential hand assessment and rehabilitation tool.


Assuntos
Articulação do Punho , Punho , Masculino , Humanos , Feminino , Reprodutibilidade dos Testes , Software , Amplitude de Movimento Articular , Fenômenos Biomecânicos
5.
Diagnostics (Basel) ; 12(12)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36553171

RESUMO

This pilot study aimed to determine the reliability of a newly developed ultrasound-based protocol for the assessment of patella diameter and sulcus angle. The diameter of the patella expressed in mm and the sulcus angle, expressed in degrees were measured in the right knee in 12 healthy participants (eight women and four men) in two separate sessions by two examiners (experienced rater and inexperienced rater) using ultrasonography according to a developed standardized protocol. The reliability was determined on the calculated intraclass correlation coefficient, ICC, expressed as a 95% confidence interval (lower bound, upper bound). For the patella diameter measurement, intra-rater and inter-rater reliability were good to excellent, with the ICC exceeding 0.836-0.998 and 0.859-0.997, respectively. The intra-rater and inter-rater reliability of the sulcus measurement was moderate to excellent, as the ICC amounted to 0.559-0.993 and 0.559-0.990, respectively. The reliability of both measures increased with the experience of the examiner. Therefore, it was determined that the newly developed protocol for an ultrasound-based assessment of patella diameter and sulcus angle is reliable. Further studies validating their clinical use should be carried out.

6.
PLoS One ; 5(2): e9202, 2010 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-20186320

RESUMO

BACKGROUND: Systems biology has embraced computational modeling in response to the quantitative nature and increasing scale of contemporary data sets. The onslaught of data is accelerating as molecular profiling technology evolves. The Dialogue for Reverse Engineering Assessments and Methods (DREAM) is a community effort to catalyze discussion about the design, application, and assessment of systems biology models through annual reverse-engineering challenges. METHODOLOGY AND PRINCIPAL FINDINGS: We describe our assessments of the four challenges associated with the third DREAM conference which came to be known as the DREAM3 challenges: signaling cascade identification, signaling response prediction, gene expression prediction, and the DREAM3 in silico network challenge. The challenges, based on anonymized data sets, tested participants in network inference and prediction of measurements. Forty teams submitted 413 predicted networks and measurement test sets. Overall, a handful of best-performer teams were identified, while a majority of teams made predictions that were equivalent to random. Counterintuitively, combining the predictions of multiple teams (including the weaker teams) can in some cases improve predictive power beyond that of any single method. CONCLUSIONS: DREAM provides valuable feedback to practitioners of systems biology modeling. Lessons learned from the predictions of the community provide much-needed context for interpreting claims of efficacy of algorithms described in the scientific literature.


Assuntos
Algoritmos , Biologia Computacional/métodos , Modelos Biológicos , Biologia de Sistemas/métodos , Animais , Análise por Conglomerados , Perfilação da Expressão Gênica/métodos , Redes Reguladoras de Genes , Humanos , Mapeamento de Interação de Proteínas/métodos , Reprodutibilidade dos Testes , Transdução de Sinais , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA