Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Am Soc Echocardiogr ; 31(11): 1190-1202.e3, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30269909

RESUMO

BACKGROUND: Tricuspid valve imaging is frequently challenging and requires the use of multiple modalities. Knowledge of limitations and methodologic discrepancies among different imaging techniques is crucial for planning transcatheter valve interventions. METHODS: Thirty-eight patients with severe symptomatic tricuspid regurgitation were included in this retrospective analysis. Tricuspid annulus (TA) measurements were made during mid-diastole using three-dimensional (3D) transthoracic echocardiographic direct planimetry (TTE_direct) and transesophageal echocardiographic direct planimetry (TEE_direct). Moreover, a semiautomated software was used to generate two-dimensional (2D) and 3D perimeter and area on transesophageal echocardiography (TEE) images. Both methods were compared with direct computed tomographic planimetry (CT_direct) and cubic spline interpolation (CT_indirect). The different TA values were used to calculate the effective regurgitant orifice area and compared with 3D Doppler vena contracta area. For tricuspid valve area TEE_direct and CT_direct as well as CT_indirect were measured. RESULTS: Agreement between TEE and computed tomography (CT) for TA sizing was obtained using semiautomated methods (3D TEE_indirect and CT_indirect). TTE_direct was overall less reliable compared with CT. TA area quantified by TEE_direct was 25% (difference 305 ± 238 mm2, P < .001, R = 0.9) and 19% (166 ± 247 mm2, P < .001, R = 0.89) smaller compared with CT_direct and CT_indirect, respectively. TA perimeter measurements by TEE_direct differed by 11% compared with CT_direct (12 ± 11 mm, P < .001, R = 0.87) and 3D CT_indirect (12 ± 11 mm, P < .001, R = 0.88), and 9% compared with 2D CT_indirect (7 ± 11 mm, P = .002, R = 0.87). TEE_direct of the TA allows the most accurate calculation of effective regurgitant orifice area compared with 3D vena contracta area (-8 ± 62 mm2, P = .50, R = 0.85). Tricuspid valve area by CT_indirect best correlated with conventional TEE_direct (80 ± 250 mm2, P = .11, R = 0.80). CONCLUSIONS: In patients with severe tricuspid regurgitation, semiautomated indirect planimetry results in high agreement between TEE and CT for TA sizing and measurement of the tricuspid valve area. TEE_direct of the TA allows the most accurate measurement of diastolic stroke volume for the calculation of regurgitation severity compared with 3D vena contracta area.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Tomografia Computadorizada Multidetectores/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
2.
J Cardiovasc Comput Tomogr ; 10(4): 316-21, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27061253

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. METHODS: 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30 mL/min) who underwent a novel VLCV protocol (20 mL of iohexol at 2.5 mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. RESULTS: VLCV patients had mean (±SD) age 86 ± 6.5, BMI 23.9 ± 3.4 kg/m(2) with 54% men; SCV patients age 83 ± 8.8, BMI 28.7 ± 5.3 kg/m(2), 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. CONCLUSIONS: This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Iohexol/administração & dosagem , Tomografia Computadorizada Multidetectores/métodos , Insuficiência Renal Crônica/complicações , Centros Médicos Acadêmicos , Administração Intravenosa , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Angiografia por Tomografia Computadorizada/efeitos adversos , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Estudos de Viabilidade , Feminino , Taxa de Filtração Glomerular , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Iohexol/efeitos adversos , Rim/fisiopatologia , Masculino , Tomografia Computadorizada Multidetectores/efeitos adversos , Cidade de Nova Iorque , Variações Dependentes do Observador , Valor Preditivo dos Testes , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA