Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 90(10): 5989-5994, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29688004

RESUMO

Plasma stability assessment under physiological temperature is an essential step for developing and optimizing antibody drug conjugate (ADC) molecules, especially those with cleavable linkers. The assessment of plasma stability often requires monitoring multiple analytes using a combination of bioanalytical assays for free payloads, conjugated payloads (or conjugated antibodies), total antibodies, and payloads that have migrated from antibodies to plasma constituent proteins. Bioanalytical assays are needed in early drug discovery to quickly screen diverse ADC candidates of different antibody constructs, linker variants, and antibody anchor sites. To improve the sensitivity and selectivity of LC/MS/MS-based assays for the assessment, immunocapture has been widely used for extracting ADCs and unconjugated antibodies from plasma samples. In this study, a novel two-step immunocapture LC/MS/MS assay was described to allow the quantification of conjugated payloads, total antibodies, and migrated payloads forming adducts with albumin in the plasma samples for stability assessment. A target antigen immobilized on magnetic beads was used to exhaustively extract the ADC and antibody-associated species. The remaining supernatant was then extracted further with anti-albumin beads for recovering the albumin-associated adducts for quantification. The method was optimized for higher efficiency and cost-effectiveness using microwave enhanced papain-based enzymatic cleavage for measuring conjugated payloads of ADCs and lysyl endopeptidase cleavage in the total antibody assay. A maleimide linker-based ADC with a proprietary payload, TAK-001, was used to demonstrate the streamlined workflow of the ADC stability assessment. The method could provide valuable evaluation of the stability of the ADC as well as the quantitative assessment of the albumin adducts formed from the linker-payload migration in mouse and human plasma. Furthermore, the method should be readily adaptable for other ADCs using thiol-maleimide conjugation chemistry.


Assuntos
Anticorpos Monoclonais/sangue , Cisteína/química , Imunoensaio , Imunoconjugados/sangue , Maleimidas/química , Albuminas/química , Animais , Anticorpos Monoclonais Humanizados , Cromatografia Líquida , Humanos , Camundongos , Espectrometria de Massas em Tandem
2.
J Pharm Sci ; 106(12): 3442-3452, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28927987

RESUMO

Regulatory agencies have recently issued drug-drug interaction guidelines, which require determination of plasma protein binding (PPB). To err on the conservative side, the agencies recommend that a 0.01 lower limit of fraction unbound (fu) be used for highly bound compounds (>99%), irrespective of the actual measured values. While this may avoid false negatives, the recommendation would likely result in a high rate of false positive predictions, resulting in unnecessary clinical studies and more stringent inclusion/exclusion criteria, which may add cost and time in delivery of new medicines to patients. In this perspective, we provide a review of current approaches to measure PPB, and important determinants in enabling the accuracy and precision in these measurements. The ability to measure fu is further illustrated by a cross-company data comparison of PPB for warfarin and itraconazole, demonstrating good concordance of the measured fu values. The data indicate that fu values of ≤0.01 may be determined accurately across laboratories when appropriate methods are used. These data, along with numerous other examples presented in the literature, support the use of experimentally measured fu values for drug-drug interaction predictions, rather than using the arbitrary cutoff value of 0.01 as recommended in current regulatory guidelines.


Assuntos
Proteínas Sanguíneas/metabolismo , Interações Medicamentosas/fisiologia , Preparações Farmacêuticas/química , Preparações Farmacêuticas/normas , Ligação Proteica/fisiologia , Animais , Indústria Farmacêutica/normas , Humanos , Preparações Farmacêuticas/metabolismo , Plasma/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA