Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Skeletal Radiol ; 52(6): 1169-1178, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36520217

RESUMO

INTRODUCTION: The osteoporosis self-assessment tool for Asians (OSTA) is a common screening tool for osteoporosis. The seventh thoracic CT (CT-T7) Hounsfield unit (HU) measured by chest CT correlates with osteoporosis. This study aimed to investigate the diagnostic value of OSTA alone, CT-T7 alone, or the combination of OSTA and CT-T7 in osteoporosis. MATERIALS AND METHODS: In this study, 1268 participants were grouped into 586 men and 682 women. We established multiple linear regression models by combining CT-T7 and OSTA. Receiver operating characteristic (ROC) curves were used to evaluate the ability to diagnose osteoporosis. RESULTS: In the male group, the mean age was 59.02 years, and 108 patients (18.4%) had osteoporosis. In the female group, the mean age was 63.23 years, and 308 patients (45.2%) had osteoporosis. By ROC curve comparison, the CT-T7 (male, AUC = 0.789, 95% CI 0.745-0.832; female, AUC = 0.835, 95% CI 0.805-0.864) in the diagnosis of osteoporosis was greater than the OSTA (male, AUC = 0.673, 95% CI 0.620-0.726; female, AUC = 0.775, 95% CI 0.741-0.810) in both the male and female groups (p < 0.001). When OSTA was combined with CT, the equation of multiple linear regression (MLR) was obtained as follows: female = 3.020-0.028*OSTA-0.004*CT-T7. In the female group, it was found that the AUC of MLR (AUC = 0.853, 95% CI 0.825-0.880) in the diagnosis of osteoporosis was larger than that of CT-T7 (p < 0.01). When the MLR was 2.65, the sensitivity and specificity were 53.9% and 90%, respectively. CONCLUSION: For a patient who has completed chest CT, CT-T7 (HU) combined with OSTA is recommended to identify the high-risk population of osteoporosis, and it has a higher diagnostic value than OSTA alone or CT-T7 alone, especially among females. For a female with MLR greater than 2.65, further DXA examination is needed.


Assuntos
Asiático , Autoavaliação Diagnóstica , Osteoporose , Radiografia Torácica , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Absorciometria de Fóton , Densidade Óssea , Osteoporose/diagnóstico , Osteoporose/diagnóstico por imagem , Osteoporose/etnologia , Medição de Risco , Tomografia Computadorizada por Raios X/métodos , Radiografia Torácica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA