Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Endocrinol Diabetes Nutr (Engl Ed) ; 66(9): 534-539, 2019 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31133475

RESUMO

OBJECTIVE: Less than one third of patients with type 1 diabetes mellitus (T1DM) achieve the cut-off value proposed as good metabolic control by most guidelines, HbA1c<7%. However, HbA1c reductions and prevention of severe hypoglycemia (SH) have shown clinically relevant benefits. The study objective therefore was to assess the effectiveness of continuous subcutaneous insulin infusion (CSII) therapy at 5 years of follow-up in a cohort of patients attending a specialized unit using HbA1c reduction and abscence of SH as combined goals. METHODS: A retrospective, observational study on 178 patients with T1DM who started CSII treatment at Hospital Clinic of Barcelona between 2003 and 2008. HbA1c levels at baseline and after 5 years of treatment with CSII and presence or absence of SH were recorded. The combined variables calculated included: a) HbA1c reduction by≥0.5 points and absence of SH in the last 2 years; b) HbA1c at 5 years<7.5% and no SH in the last 2 years; c) HbA1c<8.5% and no HG in the last 2 years, and d) HbA1c reduction by≥0.5 points and/or HbA1c<7.5% at 5 years with no SH in the last 2 years of follow-up. RESULTS: Twenty-seven of the 178 patients were excluded due to loss to follow-up or CSII discontinuation. A total of 151 patients (aged 37.4±10.5 years, 64% women, diabetes duration of 19.2±10.7 years) were therefore analyzed. The 2 main reasons for starting CSII were suboptimal metabolic control (60.9%) and severe hypoglycemia/hypoglycemia unawareness (28.5%). HbA1c levels in the total cohort and in patients with suboptimal metabolic control were 8.0±1.2 and 8.4±1.1% at CSII start and 7.8±1.2 and 8.0±1.3% at 5 years of treatment (P=.104 and P=.016) respectively. In the overall cohort, 55.5% of patients achieved at 5 years the combined goal of HbA1c<7.5% and/or HbA1c reductions≥0.5% without SH. CONCLUSIONS: After 5 years of CSII therapy, more than half of the patients achieved the combined goal of significant HbA1c reduction and absence of SH. The use of combined goals offers the opportunity to assess the effectiveness of T1DM treatment from a clinically more meaningful point of view.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Bombas de Infusão Implantáveis , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
J Hazard Mater ; 344: 1043-1056, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30216964

RESUMO

The Israeli quarry industry produces 57 Mt of raw material and ∼4-6Mt of associated sub-economical by-products annually. These sub-economical quarry fines are not used because production and transportation costs considerably exceed their retail value. Therefore these by-products, are stored in large piles of fine grain size particles, create environmental risks to their surrondings. This paper evaluates the possibility of mixing the sub-economical quarry by-products of two Israeli quarries with sub-economical Class F coal fly ash (<20wt.% CaO) to form an economical aggregate sand substitute to be used as a concrete filler product. To study the feasibility of the aggregate as partial substitute to sand in concrete several analyses, including leaching experiements (EN12457-2), analytical techinques (SEM-EDX, ICP-MS, ICP-AES, and XRD), as well as an analysis of the mechanical and chemical properties of the concrete aggregate (strength, workability, and penetration) were performed. Scrubbing quarry waste with coal fly ash was found to be very effective for reducing the leaching rate of potentially harmful trace elements. In addition, adding fly ash with quarry fines as partial substitute to sand enhanced the performance of the concrete mixture and the properties of the fresh and harden concrete.

3.
Endocrinol Diabetes Nutr ; 64(7): 377-383, 2017.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28745609

RESUMO

OBJECTIVE: Hypoglycemia is one of the most common complications to achieve a good metabolic control, and has been listed by several scientific associations as a common indication to start treatment with continuous subcutaneous insulin infusion (CSII). Use of CSII is still residual in Spain as compared to neighbouring countries, and cost of acquisition cost is one of the main reasons. This study estimates the budget impact of treatment with CSII, as compared to multiple daily insulin injections, of patients with type 1 diabetes mellitus who experience recurrent severe hypoglycemia episodes from the National Healthcare System perspective. METHODS: Budget impact was based on a retrospective, observational study evaluating the efficacy of CSII in patients with type 1 diabetes mellitus conducted at Hospital Clínic i Universitari in Barcelona, where one of the main indications for switching to CSII were recurrent severe hypoglycemia episodes. The mean number of annual episodes was 1.33 in the two years prior to CSII start and 0.08 in the last two years of follow up (p=0.003). Costs of treatment and major hypoglycemic events over a four-year period were considered. Costs were taken from different Spanish data sources and expressed in € of 2016. RESULTS: Treatment with CSII increased costs by €9,509 per patient as compared to multiple daily insulin injections (€11,902-€2,393). Cost associated to severe hypoglycemic events decreased by €19,330 per patient treated with CSIII (€1,371-€20,701). Results suggest mean total savings of €9,821 per patient during the four-year study period. CONCLUSION: The higher costs associated to CSII therapy may be totally offset by the severe hypoglycemic events prevented.


Assuntos
Orçamentos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Custos de Medicamentos/estatística & dados numéricos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Infusões Subcutâneas/economia , Sistemas de Infusão de Insulina/economia , Programas Nacionais de Saúde/economia , Adulto , Redução de Custos , Efeitos Psicossociais da Doença , Análise Custo-Benefício , Custos e Análise de Custo , Diabetes Mellitus Tipo 1/sangue , Feminino , Hemoglobinas Glicadas/análise , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Hipoglicemia/economia , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas/economia , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Recidiva , Estudos Retrospectivos , Espanha/epidemiologia
4.
J Diabetes Sci Technol ; 11(6): 1089-1095, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28633537

RESUMO

BACKGROUND: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. METHODS: We performed an extensive analysis of sensor's performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. RESULTS: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2 ± 8.6% in euglycemic range and 9.3 ± 9.3% in hyperglycemic range). The overall MARD was 12.1 ± 8.2%. We have also observed lower MARD for rates of change between 0 and 2 mg/dl. In CL therapy, the 10 trials with the best sensor spent less time in hypoglycemia (PG < 70 mg/dl) than the 10 trials with the worst sensors (2 ± 7 minutes vs 32 ± 38 minutes, respectively). CONCLUSIONS: In terms of accuracy, our results resemble to previously reported. Furthermore, our results showed that sensors with the lowest MARD spent less time in hypoglycemic range, indicating that the performance of CL algorithm to control PP was related to sensor accuracy.


Assuntos
Automonitorização da Glicemia , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Período Pós-Prandial , Adulto , Algoritmos , Biomarcadores/sangue , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemia/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Transdutores , Resultado do Tratamento
5.
Endocrinol Nutr ; 61(6): 318-22, 2014.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-24533929

RESUMO

BACKGROUND AND OBJECTIVE: Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. PATIENTS AND METHODS: Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. RESULTS: Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c <7.5% than in those with HbA1c>7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. CONCLUSIONS: More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control.


Assuntos
Automonitorização da Glicemia/estatística & dados numéricos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Software , Adulto , Algoritmos , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Sistemas Computacionais , Diabetes Mellitus Tipo 1/sangue , Relação Dose-Resposta a Droga , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Bombas de Infusão Implantáveis , Infusões Subcutâneas , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Design de Software , Resultado do Tratamento , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA