Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
J Cardiovasc Transl Res ; 15(5): 1075-1085, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35199256

RESUMO

Aortic surgeries in congenital conditions, such as hypoplastic left heart syndrome (HLHS), aim to restore and maintain the conduit and reservoir functions of the aorta. We proposed a method to assess these two functions based on 4D flow MRI, and we applied it to study the aorta in pre-Fontan HLHS. Ten pre-Fontan HLHS patients and six age-matched controls were studied to derive the advective pressure difference and viscous dissipation for conduit function, and pulse wave velocity and elastic modulus for reservoir function. The reconstructed neo-aorta in HLHS subjects achieved a good conduit function at a cost of an impaired reservoir function (69.7% increase of elastic modulus). The native descending HLHS aorta displayed enhanced reservoir (elastic modulus being 18.4% smaller) but impaired conduit function (three-fold increase in peak advection). A non-invasive and comprehensive assessment of aortic conduit and reservoir functions is feasible and has potentially clinical relevance in congenital vascular conditions.


Assuntos
Aorta Torácica , Síndrome do Coração Esquerdo Hipoplásico , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Análise de Onda de Pulso , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia
3.
Health Serv Manage Res ; 35(1): 37-47, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33256480

RESUMO

BACKGROUND: Value-Based Health Care (VBHC) is an evolving model of healthcare delivery aimed at achieving better patient outcomes at lower costs to the healthcare provider. The practise of VBHC requires efficient information systems with good reporting capability and subsequent outcome measuring. Information systems within the National Health Service (NHS) are often multiple and not necessarily integrated to one another. We therefore developed a systematic approach to collecting, validating and analysing data from multiple sources and information systems, with the aim of designing and endorsing an automatic system to capture health outcomes data in heart failure to support future VBHC models. METHODS: A retrospective cohort of heart failure patients with reduced ejection fraction undergoing Implantable Cardioverter Defibrillator (ICD) or Cardiac Resynchronization Therapy (CRT) procedures within a limited geographical area in South London were evaluated. A purpose built database was created to integrate, transform and validate health care data from multiple information systems. RESULTS: Validation analysis shows that our implemented methodology has produced a robust dataset. Our limited cohort of 134 patients does not allow for any complex statistical analysis however has identified some important themes related to outcomes and costs. CONCLUSION: We have created a validated database specific to our Trust that can be upscaled locally with ease and transferred to other health diseases. Due to variations in local procedure from one Trust to another, this methodology now requires implementation across multiple sites to understand differences in transformation of data and outcome measuring.


Assuntos
Insuficiência Cardíaca , Medicina Estatal , Atenção à Saúde , Insuficiência Cardíaca/terapia , Humanos , Londres , Estudos Retrospectivos
4.
Front Cardiovasc Med ; 8: 744779, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34765656

RESUMO

Background: The majority of data regarding tissue substrate for post myocardial infarction (MI) VT has been collected during hemodynamically tolerated VT, which may be distinct from the substrate responsible for VT with hemodynamic compromise (VT-HC). This study aimed to characterize tissue at diastolic locations of VT-HC in a porcine model. Methods: Late Gadolinium Enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging was performed in eight pigs with healed antero-septal infarcts. Seven pigs underwent electrophysiology study with venous arterial-extra corporeal membrane oxygenation (VA-ECMO) support. Tissue thickness, scar and heterogeneous tissue (HT) transmurality were calculated at the location of the diastolic electrograms of mapped VT-HC. Results: Diastolic locations had median scar transmurality of 33.1% and a median HT transmurality 7.6%. Diastolic activation was found within areas of non-transmural scar in 80.1% of cases. Tissue activated during the diastolic component of VT circuits was thinner than healthy tissue (median thickness: 5.5 mm vs. 8.2 mm healthy tissue, p < 0.0001) and closer to HT (median distance diastolic tissue: 2.8 mm vs. 11.4 mm healthy tissue, p < 0.0001). Non-scarred regions with diastolic activation were closer to steep gradients in thickness than non-scarred locations with normal EGMs (diastolic locations distance = 1.19 mm vs. 9.67 mm for non-diastolic locations, p < 0.0001). Sites activated late in diastole were closest to steep gradients in tissue thickness. Conclusions: Non-transmural scar, mildly decreased tissue thickness, and steep gradients in tissue thickness represent the structural characteristics of the diastolic component of reentrant circuits in VT-HC in this porcine model and could form the basis for imaging criteria to define ablation targets in future trials.

5.
Int J Cardiol Heart Vasc ; 32: 100694, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33392384

RESUMO

AIMS: Left atrial (LA) remodelling is a common feature of many cardiovascular pathologies and is a sensitive marker of adverse cardiovascular outcomes. The aim of this study was to establish normal ranges for LA parameters derived from coronary computed tomographic angiography (CCTA) imaging using a standardised image processing pipeline to establish normal ranges in a previously described cohort. METHODS: CCTA imaging from 193 subjects recruited to the Budapest GLOBAL twin study was analysed. Indexed LA cavity volume (LACVi), LA surface area (LASAi), wall thickness and LA tissue volume (LATVi) were calculated. Wall thickness maps were combined into an atlas. Indexed LA parameters were compared with clinical variables to identify early markers of pathological remodelling. RESULTS: LACVi is similar between sexes (31 ml/m2 v 30 ml/m2) and increased in hypertension (33 ml/m2 v 29 ml/m2, p = 0.009). LASAi is greater in females than males (47.8 ml/m2 v 45.8 ml/m2 male, p = 0.031). Median LAWT was 1.45 mm. LAWT was lowest at the inferior portion of the posterior LA wall (1.14 mm) and greatest in the septum (median = 2.0 mm) (p < 0.001). Conditions known to predispose to the development of AF were not associated with differences in tissue thickness. CONCLUSIONS: The reported LACVi, LASAi, LATVi and tissue thickness derived from CCTA may serve as reference values for this age group and clinical characteristics for future studies. Increased LASAi in females in the absence of differences in LACVi or LATVi may indicate differential LA shape changes between the sexes. AF predisposing conditions, other than sex, were not associated with detectable changes in LAWT.Clinical trial registration:http://www.ClinicalTrials.gov/NCT01738828.

6.
Value Health ; 23(11): 1444-1452, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33127015

RESUMO

OBJECTIVES: Given the limited diagnostic accuracy of radiographs on presentation to the emergency department (ED), the management of suspected scaphoid fractures remains clinically challenging and poses an unknown economic burden to healthcare systems. We aimed to evaluate the cost-effectiveness of immediate magnetic resonance imaging (MRI) in the management of patients presenting with suspected scaphoid fracture to an ED in England. METHODS: A pragmatic, randomized, single-center trial compared the use of immediate MRI in the ED against standard care with radiographs only. Participants' use of healthcare services and costs were estimated from primary care and secondary care databases and questionnaires at baseline, 1, 3, and 6 months postrecruitment. Costs were compared using generalized linear models and combined with quality-adjusted life years (QALYs, based on the EQ-5D-5L) to estimate cost-effectiveness at 6 months postrecruitment. Cost-effectiveness acceptability curves and bootstrapping techniques were used to estimate the probability of cost-effectiveness at different willingness-to-pay (WTP) thresholds. Four deterministic sensitivity scenarios were considered around key parameters. RESULTS: The MRI intervention dominated standard care in the base case and all 4 deterministic sensitivity scenarios, costing less and achieving more QALY gains, with a probability of 100% of being cost-effective at 6 months using the conventional United Kingdom WTP thresholds of £20 000 to £30 000 per QALY. CONCLUSION: The use of immediate MRI is a cost-effective intervention in the management of suspected scaphoid fractures in a Central Hospital in London. Routine clinical practice at our institution has been changed to include the intervention.


Assuntos
Análise Custo-Benefício , Serviço Hospitalar de Emergência/economia , Fraturas Ósseas/diagnóstico por imagem , Imageamento por Ressonância Magnética/economia , Osso Escafoide/diagnóstico por imagem , Inglaterra , Humanos , Anos de Vida Ajustados por Qualidade de Vida
7.
Heart ; 106(12): 931-937, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31932286

RESUMO

OBJECTIVES: Transvenous lead extraction (TLE) poses a significant economic and resource burden on healthcare systems; however, limited data exist on its true cost. We therefore estimate real-world healthcare reimbursement costs of TLE to the UK healthcare system at a single extraction centre. METHODS: Consecutive admissions entailing TLE at a high-volume UK centre between April 2013 and March 2018 were prospectively recorded in a computer registry. In the hospital's National Health Service (NHS) clinical coding/reimbursement database, 447 cases were identified. Mean reimbursement cost (n=445) and length of stay (n=447) were calculated. Ordinary least squares regressions estimated the relationship between cost (bed days) and clinical factors. RESULTS: Mean reimbursement cost per admission was £17 399.09±£13 966.49. Total reimbursement for all TLE admissions was £7 777 393.51. Mean length of stay was 16.3±15.16 days with a total of 7199 bed days. Implantable cardioverter-defibrillator and cardiac resynchronisation therapy defibrillator devices incurred higher reimbursement costs (70.5% and 68.7% higher, respectively, both p<0.001). Heart failure and prior valve surgery also incurred significantly higher reimbursement costs. Prior valve surgery and heart failure were associated with 8.3 (p=0.017) and 5.5 (p=0.021) additional days in hospital, respectively. CONCLUSIONS: Financial costs to the NHS from TLE are substantial. Consideration should therefore be given to cost/resource-sparing potential of leadless/extravascular cardiac devices that negate the need for TLE particularly in patients with prior valve surgery and/or heart failure. Additionally, use of antibiotic envelopes and other interventions that reduce infection risk in patients receiving transvenous leads should be considered.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/economia , Recursos em Saúde/economia , Custos Hospitalares , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Medicina Estatal/economia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Análise Custo-Benefício , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Reembolso de Seguro de Saúde , Tempo de Internação/economia , Londres , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/economia , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 30(10): 1894-1903, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31397511

RESUMO

INTRODUCTION: Multiple cardiac magnetic resonance (CMR)-derived indices of atrial fibrillation (AF) substrate have been shown in isolation to predict long-term outcome following catheter ablation. Left atrial (LA) fibrosis, LA volume, LA ejection fraction (EF), left ventricular ejection fraction (LVEF), LA shape (sphericity) and pulmonary vein anatomy have all been shown to correlate with late AF recurrence. This study aimed to validate and assess the relative contribution of multiple indices in a long-term single-center study. METHODS AND RESULTS: Eighty-nine patients (53% paroxysmal AF, 73% male) underwent comprehensive CMR study before first-time AF ablation (median follow-up 726 days [IQR: 418-1010 days]). The 3D late gadolinium-enhanced acquisition (1.5T, 1.3 × 1.3 × 2 mm) was quantified for fibrosis; LA volume and sphericity were assessed on manual segmentation at atrial diastole; LAEF and LVEF were quantified on multislice cine imaging. AF recurred in 43 patients (48%) overall (31 at 1 year). In the recurrence group, LA fibrosis was higher (42% vs 29%; hazard ratio [HR]: 1.032; P = .002), left atrial ejection fraction (LAEF) lower (25% vs 34%; HR: 0.063; P = .016) and LVEF lower (57% vs 63%; HR: 0.011; P = .008). LA volume (135 vs 124 mL) and sphericity (0.819 vs 0.822) were similar. Multivariate Cox regression analysis was adjusted for age and sex (Model 1), additionally AF type (Model 2) and combined (Model 3). In Models 1 and 2, LA fibrosis, LAEF, and LVEF were independently associated with outcome, but only LA fibrosis was independent in Model 3 (HR: 1.021; P = .022). CONCLUSIONS: LAEF, LVEF, and LA fibrosis differed significantly in the AF recurrence cohort. However, on combined multivariate analysis only LA fibrosis remained independently associated with outcome.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Imagem Cinética por Ressonância Magnética , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Feminino , Fibrose , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
10.
Europace ; 21(9): 1432-1441, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31219547

RESUMO

AIMS: Potential advantages of real-time magnetic resonance imaging (MRI)-guided electrophysiology (MR-EP) include contemporaneous three-dimensional substrate assessment at the time of intervention, improved procedural guidance, and ablation lesion assessment. We evaluated a novel real-time MR-EP system to perform endocardial voltage mapping and assessment of delayed conduction in a porcine ischaemia-reperfusion model. METHODS AND RESULTS: Sites of low voltage and slow conduction identified using the system were registered and compared to regions of late gadolinium enhancement (LGE) on MRI. The Sorensen-Dice similarity coefficient (DSC) between LGE scar maps and voltage maps was computed on a nodal basis. A total of 445 electrograms were recorded in sinus rhythm (range: 30-186) using the MR-EP system including 138 electrograms from LGE regions. Pacing captured at 103 sites; 47 (45.6%) sites had a stimulus-to-QRS (S-QRS) delay of ≥40 ms. Using conventional (0.5-1.5 mV) bipolar voltage thresholds, the sensitivity and specificity of voltage mapping using the MR-EP system to identify MR-derived LGE was 57% and 96%, respectively. Voltage mapping had a better predictive ability in detecting LGE compared to S-QRS measurements using this system (area under curve: 0.907 vs. 0.840). Using an electrical threshold of 1.5 mV to define abnormal myocardium, the total DSC, scar DSC, and normal myocardium DSC between voltage maps and LGE scar maps was 79.0 ± 6.0%, 35.0 ± 10.1%, and 90.4 ± 8.6%, respectively. CONCLUSION: Low-voltage zones and regions of delayed conduction determined using a real-time MR-EP system are moderately associated with LGE areas identified on MRI.


Assuntos
Doença do Sistema de Condução Cardíaco/diagnóstico por imagem , Doença do Sistema de Condução Cardíaco/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Animais , Doença do Sistema de Condução Cardíaco/etiologia , Doença do Sistema de Condução Cardíaco/cirurgia , Ablação por Cateter , Modelos Animais de Doenças , Imageamento por Ressonância Magnética/métodos , Masculino , Traumatismo por Reperfusão Miocárdica/complicações , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Cirurgia Assistida por Computador , Sus scrofa , Suínos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
11.
J Med Econ ; 22(5): 464-470, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30744444

RESUMO

BACKGROUND AND AIMS: Infection is a serious and expensive complication of Cardiac Implantable Electronic Device (CIED) procedures. A retrospective based cost analysis was performed to estimate Trust level savings of using the TYRX antibacterial envelope as a primary prevention measure against infection in a tertiary referral centre in South London, UK. METHODS: A retrospective cohort of heart failure patients with reduced ejection fraction undergoing Implantable Cardioverter Defibrillator (ICD) or Cardiac Resynchronization Therapy (CRT) procedures were evaluated. Decision-analytic modelling was performed to determine economic savings of using the envelope during CIED procedure vs CIED procedure alone. RESULTS: Over a 12 month follow-up period following CIED procedure, the observed infection rate was 3.14% (n = 5/159). The average cost of a CIED infection inpatient admission was £41,820 and, further to economic analysis, the additional costs attributable to infection was calculated at £62,213.94. A cost saving of £624 per patient by using TYRX during CIED procedure as a primary preventative measure against infection was estimated. CONCLUSIONS: TYRX would be a cost-saving treatment option amongst heart failure patients undergoing ICD and CRT device procedures based on analysis in the local geographical area of South London. If upscaled to the UK population, we estimate potential cost savings for the National Health Service (NHS).


Assuntos
Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/cirurgia , Infecções Relacionadas à Prótese/prevenção & controle , Análise Custo-Benefício , Técnicas de Apoio para a Decisão , Humanos , Modelos Econômicos , Infecções Relacionadas à Prótese/economia , Estudos Retrospectivos , Centros de Atenção Terciária , Reino Unido
12.
J Cardiovasc Electrophysiol ; 30(1): 67-77, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30255652

RESUMO

INTRODUCTION: The VisiTag module (CARTO3) provides an objective assessment of radiofrequency (RF) ablation parameters. This study aimed to determine the predictive value and optimal VisiTag threshold settings for prediction of gaps in mature atrial scar, as assessed non-invasively using cardiac magnetic resonance (CMR) imaging. METHODS: Twenty-four subjects (11 paroxysmal atrial fibrillation) underwent first-time RF ablation with operators blinded to VisiTag data. Three-dimensional late gadolinium enhancement (LGE) CMR scans were performed at 3 months (1.3 × 1.3 × 4 mm3 ). A survey of UK operators defined the standard VisiTag settings ("Force," 8 g; "Time," 10 seconds; "Percentage Time," 50%; "Range," 3 mm; "Impedance" and "Temperature" "off"). Each ablation procedure was exported 27 times, varying single VisiTag parameters from default values. The presence of gaps in VisiTag markers (18 sectors) was assessed for each export and compared with gaps in CMR enhancement. RESULTS: At default settings, VisiTag gaps were specific (97.5%) but less sensitive (50.4%) for CMR gaps. Sensitivity improved at higher thresholds (89.2% at 20 g, 85.6% at 30 seconds, 88.5% impedance 10 Ω, 92.8% temperature 42°C), but with a lower positive predictive value (PPV) (42.3%, 42.7%, 41.1%, and 37.7%, respectively, vs 90.9% at baseline). "Force" thresholds demonstrated stable PPV from 2 to 8 g (P = 0.24), but a rapid fall at forces more than 10 g. The binomial logistic regression model explained 41.7% of gaps; χ 2 (4), 148; P < 0.0001, correctly classifying 82% of cases (specificity 94.9%, sensitivity 56.8%). CONCLUSION: Gaps in VisiTags predict gaps in CMR LGE enhancement with high specificity at default settings. Sensitivity may be improved using more stringent thresholds but at the potential cost of unnecessary ablation, particularly when a force more than 10 g is stipulated.


Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento por Ressonância Magnética , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cicatriz/etiologia , Cicatriz/fisiopatologia , Meios de Contraste/administração & dosagem , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
13.
Int J Cardiol ; 257: 131-136, 2018 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-29506684

RESUMO

AIMS: The 2014 National Institute of Clinical Excellence (NICE) guidelines on the management of acute heart failure recommended using a plasma NT-proBNP threshold of 300pg/ml to assist in ruling out the diagnosis of heart failure (HF), updating previous guidelines recommending using a threshold of 400pg/ml. NICE based their recommendations on 6 studies performed in other countries. This study sought to determine the diagnostic and economic implications of using these thresholds in a large unselected UK population. METHODS: Patient and clinical demographics were recorded for all consecutive suspected HF patients over 12months, as well as clinical outcomes including time to HF hospitalisation and time to death (follow up 15.8months). RESULTS: Of 1995 unselected patients admitted with clinically suspected HF, 1683 (84%) had a NTproBNP over the current NICE recommended threshold, of which 35% received a final diagnosis of HF. Lowering the threshold from 400 to 300pg/ml would have involved screening an additional 61 patients and only would have identified one new patient with HF (sensitivity 0.985, NPV 0.976, area under the curve (AUC) at 300pg/ml 0.67; sensitivity 0.983, NPV 0.977, AUC 0.65 at 400pg/ml). The economic implications of lowering the threshold would have involved additional costs of £42,842.04 (£702.33 per patient screened, or £ 42,824.04 per new HF patient). CONCLUSION: Applying the recent updated NICE guidelines to an unselected real world population increases the AUC but would have a significant economic impact and only identified one new patient with heart failure.


Assuntos
Análise Custo-Benefício/métodos , Insuficiência Cardíaca/economia , Hospitalização/economia , Peptídeo Natriurético Encefálico/economia , Fragmentos de Peptídeos/economia , Guias de Prática Clínica como Assunto/normas , Biomarcadores/sangue , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Hospitalização/tendências , Humanos , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Padrões de Referência
14.
EuroIntervention ; 13(9): e1080-e1083, 2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-28555593

RESUMO

AIMS: Coronary artery fistulae represent one of the most challenging anatomical defects to define accurately. We aimed to investigate the additional benefit conferred by volume rendering of tomographic images and 3D printing for diagnosis and interventional planning. METHODS AND RESULTS: Four cases of coronary fistulae were considered for transcatheter closure. Multidetector computed tomography (three cases) or cardiac magnetic resonance (one case) images were acquired and segmented using Mimics software. Each case was reviewed after incremental consideration of diagnostic resources: two cardiologists reported source and volume-rendered images; device closure was discussed by the interventional cardiology team. All diagnoses and planned management were reviewed after inspection of a 3D model. Using source images alone, both cardiologists correctly described the course and drainage in two out of four cases. Aided by volume rendering, this improved to three out of four cases. Inspection of the 3D printed model prompted the planned interventional approach and device sizing to be altered in two out of four cases. In one out of four cases, the intervention was abandoned after inspection of the 3D printed model. CONCLUSIONS: Diagnosis and management of patients with coronary artery fistulae rely on detailed image analyses. 3D models add value when determining the feasibility of, and the approach to intervention in these cases.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Modelos Anatômicos , Fístula Vascular/diagnóstico por imagem , Adulto , Idoso , Técnicas de Imagem Cardíaca , Pré-Escolar , Tomada de Decisão Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Impressão Tridimensional
15.
JACC Clin Electrophysiol ; 3(2): 107-116, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28280785

RESUMO

OBJECTIVES: The objective of this study was to evaluate the cost-effectiveness of quadripolar versus bipolar cardiac resynchronization defibrillator therapy systems. BACKGROUND: Quadripolar left ventricular (LV) leads for cardiac resynchronization therapy reduce phrenic nerve stimulation (PNS) and are associated with reduced mortality compared with bipolar leads. METHODS: A total of 606 patients received implants at 3 UK centers (319 Q, 287 B), between 2009 and 2014; mean follow-up was 879 days. Rehospitalization episodes were costed at National Health Service national tariff rates, and EQ-5D utility values were applied to heart failure admissions, acute coronary syndrome events, and mortality data, which were used to estimate quality-adjusted life-year differences over 5 years. RESULTS: Groups were matched with regard to age and sex. Patients with quadripolar implants had a lower rate of hospitalization than those with bipolar implants (42.6% vs. 55.4%; p = 0.002). This was primarily driven by fewer hospital readmissions for heart failure (51 [16%] vs. 75 [26.1%], respectively, for quadripolar vs. bipolar implants; p = 0.003) and generator replacements (9 [2.8%] vs. 19 [6.6%], respectively; p = 0.03). Hospitalization for suspected acute coronary syndrome, arrhythmia, device explantation, and lead revisions were similar. This lower health-care utilization cost translated into a cumulative 5-year cost saving for patients with quadripolar systems where the acquisition cost was <£932 (US $1,398) compared with bipolar systems. Probabilistic sensitivity analysis results mirrored the deterministic calculations. For the average additional price of £1,200 (US $1,800) over a bipolar system, the incremental cost-effective ratio was £3,692 per quality-adjusted life-year gained (US $5,538), far below the usual willingness-to-pay threshold of £20,000 (US $30,000). CONCLUSIONS: In a UK health-care 5-year time horizon, the additional purchase price of quadripolar cardiac resynchronization defibrillator therapy systems is largely offset by lower subsequent event costs up to 5 years after implantation, which makes this technology highly cost-effective compared with bipolar systems.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Síndrome Coronariana Aguda/economia , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Arritmias Cardíacas/economia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/economia , Estimulação Cardíaca Artificial/mortalidade , Terapia de Ressincronização Cardíaca/economia , Terapia de Ressincronização Cardíaca/mortalidade , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Hospitalização/economia , Humanos , Masculino , Desenho de Prótese , Anos de Vida Ajustados por Qualidade de Vida , Sistema de Registros , Reino Unido/epidemiologia
16.
Ann Biomed Eng ; 45(3): 605-618, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27605213

RESUMO

Patient-specific modelling has emerged as a tool for studying heart function, demonstrating the potential to provide non-invasive estimates of tissue passive stiffness. However, reliable use of model-derived stiffness requires sufficient model accuracy and unique estimation of model parameters. In this paper we present personalised models of cardiac mechanics, focusing on improving model accuracy, while ensuring unique parametrisation. The influence of principal model uncertainties on accuracy and parameter identifiability was systematically assessed in a group of patients with dilated cardiomyopathy ([Formula: see text]) and healthy volunteers ([Formula: see text]). For all cases, we examined three circumferentially symmetric fibre distributions and two epicardial boundary conditions. Our results demonstrated the ability of data-derived boundary conditions to improve model accuracy and highlighted the influence of the assumed fibre distribution on both model fidelity and stiffness estimates. The model personalisation pipeline-based strictly on non-invasive data-produced unique parameter estimates and satisfactory model errors for all cases, supporting the selected model assumptions. The thorough analysis performed enabled the comparison of passive parameters between volunteers and dilated cardiomyopathy patients, illustrating elevated stiffness in diseased hearts.


Assuntos
Cardiomiopatia Dilatada , Ventrículos do Coração , Modelos Cardiovasculares , Miocárdio , Adulto , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Pericárdio/fisiopatologia , Medicina de Precisão/métodos
17.
JACC Clin Electrophysiol ; 1(5): 421-431, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29759471

RESUMO

OBJECTIVES: This study sought to determine the effect of contact force (CF) on atrial lesion size, quality, and transmurality by using a chronic porcine model of radiofrequency ablation. BACKGROUND: CF is a major determinant of ventricular lesion formation, but uncertainty exists regarding the most appropriate CF parameters to safely achieve permanent, transmural lesions in the atria. METHODS: Intercaval linear ablation (30 W, 42°C, 17 ml/min irrigation) was performed in 8 Göttingen minipigs by using a force-sensing catheter with CF >20 g (high force) or <10 g (low force) at alternate ends of the line, separated by an intentional gap. Voltage mapping and cardiovascular magnetic resonance (CMR) imaging were performed pre-ablation, immediately after ablation, and at 2 months' post-procedure. Lesions were sectioned orthogonal to the axis of ablation to assess transmurality. RESULTS: Mean CF was 22.6 ± 11.4 g and 7.8 ± 4.0 g in the high and low CF regions. Acute tissue edema was greater with high CF, both caudally (7.0 mm vs. 4.6 mm; p = 0.016) and cranially (6.9 mm vs. 4.6 mm; p = 0.038). There was no difference in chronic lesion size (voltage mapping) or volume (late gadolinium enhancement CMR) between high and low CF regions. There was no difference in scar density (assessed by low-voltage criteria and late gadolinium enhancement signal intensity) or histological transmurality between high and low CF regions. CONCLUSIONS: Although high CF (>20 g) resulted in more acute tissue edema than low CF (<10 g), chronically there was no difference in lesion size, quality, or transmurality. Appropriate CF targets for atrial ablation may be lower than previously thought.

18.
Circ Cardiovasc Imaging ; 7(4): 679-89, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24871347

RESUMO

BACKGROUND: The incidence of abdominal aortic aneurysms (AAAs) has increased during the last decades. However, there is still controversy about the management of medium-sized AAAs. Therefore, novel biomarkers, besides aneurysmal diameter, are needed to assess aortic wall integrity and risk of rupture. Elastin is the key protein for maintaining aortic wall tensile strength and stability. The progressive breakdown of structural proteins, in particular, medial elastin, is responsible for the inability of the aortic wall to withstand intraluminal hemodynamic forces. Here, we evaluate the usefulness of elastin-specific molecular MRI for the in vivo characterization of AAAs. METHODS AND RESULTS: To induce AAAs, ApoE(-/-) mice were infused with angiotensin-II. An elastin-specific magnetic resonance molecular imaging agent (ESMA) was administered after 1, 2, 3, and 4 weeks of angiotensin-II infusion to assess elastin composition of the aorta (n=8 per group). The high signal provided by ESMA allowed for imaging with high spatial resolution, resulting in an accurate assessment of ruptured elastic laminae and the compensatory expression of elastic fibers. In vivo contrast-to-noise ratios and R1-relaxation rates after ESMA administration were in good agreement with ex vivo histomorphometry (Elastica van Gieson stain) and gadolinium concentrations determined by inductively coupled plasma mass spectroscopy. Electron microscopy confirmed colocalization of ESMA with elastic fibers. CONCLUSIONS: Changes in elastin content could be readily delineated and quantified at different stages of AAAs by elastin-specific molecular magnetic resonance imaging. ESMA-MRI offers potential for the noninvasive detection of the aortic rupture site prior to dilation of the aorta and the subsequent in vivo monitoring of compensatory repair processes during the progression of AAAs.


Assuntos
Aorta Abdominal/química , Aneurisma da Aorta Abdominal/diagnóstico , Elastina/análise , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Animais , Aorta Abdominal/fisiopatologia , Aorta Abdominal/ultraestrutura , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Animais de Doenças , Elasticidade , Masculino , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica
19.
Eur Heart J Cardiovasc Imaging ; 15(3): 257-66, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23946284

RESUMO

BACKGROUND: Accurate assessment of right ventricular (RV) volumes and function is important in patients with hypoplastic left heart syndrome (HLHS). We prospectively sought to determine the reproducibility of three-dimensional (3D) echocardiography and its agreement with cardiac magnetic resonance imaging (CMR) in HLHS. METHODS AND RESULTS: Twenty-eight patients underwent CMR followed immediately by transthoracic 3D echocardiography under general anaesthesia. Semi-automated border detection software was used to determine echocardiographic RV volumes. Inter- and intra-observer variability, correlation and levels of agreement between techniques were determined. The median age was 0.37 years (0.18-9.28 years) and weight 6.24 kg (3.42-32.50 kg). Intra- and inter-observer variability was excellent for both techniques. Median (range) measurements for 3D echocardiography and CMR were; end-diastolic volume (EDV) 23.6 mL (6.5-63.2) and 30.6 mL (11.8-87.9), end-systolic volume (ESV) 12.6 mL (3.7-37.0) and 14.9 mL (5.8-33.9), stroke volume (SV) 11.2 mL (2.8-33.0) and 17.1 mL (6.0-54.1), ejection fraction (EF) 48.2% (31.2-64.9), and 56.5% (42.7-72.2). Correlation coefficients were r = 0.85, 0.84, 0.83, and 0.74, respectively (P < 0.01 for all). Volumetric data were expressed as a percentage of the echocardiographic volume to CMR volume. When compared with CMR, 3D echocardiography underestimated EDV, ESV and SV by 26.7% (SD ± 20.2), 10.6% (±28.1), and 37.5% (±20.1), respectively. The difference in volume appeared largest at low ventricular volumes. EF was 8.3% (±7.3) lower by 3D echocardiography compared with CMR. CONCLUSION: Both 3D echocardiography and CMR volumes appear highly reproducible. Measurements obtained by 3D echocardiography are significantly lower than those obtained by CMR, with wide limits of agreement such that these two methods cannot be used interchangeably.


Assuntos
Ecocardiografia Tridimensional/métodos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/patologia , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Volume Sistólico , Disfunção Ventricular Esquerda/patologia
20.
JACC Cardiovasc Imaging ; 6(8): 864-73, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23735442

RESUMO

OBJECTIVES: Type II activation describes the U-shaped electrical activation of the left ventricle (LV) with a line of block in patients with left bundle branch block (LBBB). We sought to determine if a corresponding pattern of contraction could be identified using cardiac magnetic resonance (CMR) cine imaging and whether this predicted response to cardiac resynchronization therapy (CRT). BACKGROUND: U-shaped LV electrical activation in LBBB has been shown to predict favorable response to CRT. It is not known if the degree of electromechanical coupling is such that the same is true for LV contraction patterns. METHODS: A total of 52 patients (48% ischemic) scheduled for CRT implantation prospectively underwent pre-implantation CMR cine analysis using endocardial contour tracking software to generate time-volume curves and contraction propagation maps. These were analyzed to assess the contraction sequence of the LV. The effect of contraction pattern on CRT response in terms of reverse remodeling (RR) and clinical parameters (New York Heart Association functional class, 6-min walk distance and Heart Failure Questionnaire score) was assessed at 6 months. RESULTS: Two types of contraction pattern were identified; homogenous spread from septum to lateral wall (type I, n = 27) and presence of block with a subsequent U-shaped contraction pattern (type II, n = 25). Rates of RR in those with a type 2 pattern were significantly greater at 6 months (80% vs. 26%, p < 0.001) as was mean increase in 6-min walk distance (126 ± 106 m vs. 55 ± 60 m; p = 0.004). CONCLUSIONS: Cine CMR can identify a U-shaped pattern of contraction which predicts increased echocardiographic and clinical response rates to CRT in patients with LBBB.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular Esquerda , Idoso , Bloqueio de Ramo/fisiopatologia , Teste de Esforço , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Software , Inquéritos e Questionários , Resultado do Tratamento , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA