Magn Reson Med ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38725136

RESUMO

PURPOSE: To investigate the effect of particle size on liver R 2 * $$ {\mathrm{R}}_2^{\ast } $$ by Monte Carlo simulation and phantom studies at both 1.5 T and 3.0 T. METHODS: Two kinds of particles (i.e., iron sphere and fat droplet) with varying sizes were considered separately in simulation and phantom studies. MRI signals were synthesized and analyzed for predicting R 2 * $$ {\mathrm{R}}_2^{\ast } $$ , based on simulations by incorporating virtual liver model, particle distribution, magnetic field generation, and proton movement into phase accrual. In the phantom study, iron-water and fat-water phantoms were constructed, and each phantom contained 15 separate vials with combinations of five particle concentrations and three particle sizes. R 2 * $$ {\mathrm{R}}_2^{\ast } $$ measurements in the phantom were made at both 1.5 T and 3.0 T. Finally, differences in R 2 * $$ {\mathrm{R}}_2^{\ast } $$ predictions or measurements were evaluated across varying particle sizes. RESULTS: In the simulation study, strong linear and positively correlated relationships were observed between R 2 * $$ {\mathrm{R}}_2^{\ast } $$ predictions and particle concentrations across varying particle sizes and magnetic field strengths ( r ≥ 0.988 $$ r\ge 0.988 $$ ). The relationships were affected by iron sphere size ( p < 0.001 $$ p<0.001 $$ ), where smaller iron sphere size yielded higher predicted R 2 * $$ {\mathrm{R}}_2^{\ast } $$ , whereas fat droplet size had no effect on R 2 * $$ {\mathrm{R}}_2^{\ast } $$ predictions ( p ≥ 0.617 $$ p\ge 0.617 $$ ) for constant total fat concentration. Similarly, the phantom study showed that R 2 * $$ {\mathrm{R}}_2^{\ast } $$ measurements were relatively sensitive to iron sphere size ( p ≤ 0.004 $$ p\le 0.004 $$ ) unlike fat droplet size ( p ≥ 0.223 $$ p\ge 0.223 $$ ). CONCLUSION: Liver R 2 * $$ {\mathrm{R}}_2^{\ast } $$ is affected by iron sphere size, but is relatively unaffected by fat droplet size. These findings may lead to an improved understanding of the underlying mechanisms of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ relaxometry in vivo, and enable improved quantitative MRI phantom design.

3.
Comput Methods Programs Biomed ; 233: 107494, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36965302

RESUMO

BACKGROUND AND OBJECTIVE: To model hepatic steatosis in adult humans with non-alcoholic fatty liver disease based on stereology and spatial distribution of fat droplets from liver biopsy specimens. METHODS: Histological analysis was performed on 30 adult human liver biopsy specimens with varying degrees of steatosis. Morphological features of fat droplets were characterized by gamma distribution function (GDF) in both two-dimensional (2D) and three-dimensional (3D) spaces from three aspects: 1) size distribution indicating non-uniformity of fat droplets in radius; 2) nearest neighbor distance distribution indicating heterogeneous accumulation (i.e., clustering) of fat droplets; 3) regional anisotropy indicating inter-regional variability in fat fraction (FF). To generalize the morphological description of hepatic steatosis to different FFs, correlation analysis was performed among the estimated GDF parameters and FFs for all specimens. Finally, Monte Carlo modeling of hepatic steatosis was developed to simulate fat droplet distribution in tissue. RESULTS: Morphological features, including size and nearest neighbor distance in 2D and 3D spaces as well as regional anisotropy, statistically captured the distribution of fat droplets by the GDF fit (R2 > 0.54). The estimated GDF parameters (i.e., scale and shape parameters) and FFs were well correlated, with R2 > 0.55. In addition, simulated 3D liver morphological models demonstrated similar sections to real histological samples both visually and quantitatively. CONCLUSIONS: The morphology of hepatic steatosis is well characterized by stereology and spatial distribution of fat droplets. Simulated models demonstrate similar appearances to real histological samples. Furthermore, the model may help understand MRI signal behavior in the presence of liver steatosis.


Assuntos
Fígado , Hepatopatia Gordurosa não Alcoólica , Adulto , Humanos , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Imageamento por Ressonância Magnética/métodos , Método de Monte Carlo , Índice de Gravidade de Doença
4.
Eur Radiol ; 32(1): 533-541, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34268596

RESUMO

OBJECTIVES: To compare the diagnostic accuracy of generalist radiologists working in a community setting against abdominal radiologists working in an academic setting for the interpretation of MR when diagnosing acute appendicitis among emergency department patients. METHODS: This observational study examined MR image interpretation (non-contrast MR with diffusion-weighted imaging and intravenous contrast-enhanced MR) from a prospectively enrolled cohort at an academic hospital over 18 months. Eligible patients had an abdominopelvic CT ordered to evaluate for appendicitis and were > 11 years old. The reference standard was a combination of surgery and pathology results, phone follow-up, and chart review. Six radiologists blinded to clinical information, three each from community and academic practices, independently interpreted MR and CT images in random order. We calculated test characteristics for both individual and group (consensus) diagnostic accuracy then performed Chi-square tests to identify any differences between the subgroups. RESULTS: Analysis included 198 patients (114 women) with a mean age of 31.6 years and an appendicitis prevalence of 32.3%. For generalist radiologists, the sensitivity and specificity (95% confidence interval) were 93.8% (84.6-98.0%) and 88.8% (82.2-93.2%) for MR and 96.9% (88.7-99.8%) and 91.8% (85.8-95.5%) for CT. For fellowship-trained radiologists, the sensitivity and specificity were 96.9% (88.2-99.5%) and 89.6% (82.8-94%) for MR and 98.4% (90.5-99.9%) and 93.3% (87.3-96.7%) for CT. No statistically significant differences were detected between radiologist groups (p = 1.0, p = 0.53, respectively) or when comparing MR to CT (p = 0.21, p = 0.17, respectively). CONCLUSIONS: MR is a reliable, radiation-free imaging alternative to CT for the evaluation of appendicitis in community-based generalist radiology practices. KEY POINTS: • There was no significant difference in MR image interpretation accuracy between generalist and abdominal fellowship-trained radiologists when evaluating sensitivity (p = 1.0) and specificity (p = 0.53). • There was no significant difference in accuracy comparing MR to CT imaging for diagnosing appendicitis for either sensitivity (p = 0.21) or specificity (p = 0.17). • With experience, generalist radiologists enhanced their MR interpretation accuracy as demonstrated by improved interpretation sensitivity (OR 2.89 CI 1.44-5.77, p = 0.003) and decreased mean interpretation time (5 to 3.89 min).


Assuntos
Apendicite , Adulto , Apendicite/diagnóstico por imagem , Criança , Bolsas de Estudo , Feminino , Humanos , Radiologistas , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
5.
NMR Biomed ; 34(12): e4604, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34462976

RESUMO

The aim of this study was to reproduce relaxivity-iron calibration in hepatic iron overload using a Monte Carlo model, and further extend the model with multiple spin echo (MSE) imaging. As previously reported, relationships between relaxation rates ( R2* and single spin echo R2 ) and liver iron concentration (LIC) can be characterized by a Monte Carlo model incorporating realistic liver structure, iron distribution, and proton mobility. In this study, relaxivity-iron calibration curves at 1.5 and 3.0 T were simulated using the Monte Carlo model. Furthermore, the model was extended with MSE imaging, and iron calibrations were evaluated using two different fitting models: mononexponential with a constant offset and nonmonoexponential. Results consistent with previous empirical calibrations and Monte Carlo predictions were accurately reproduced for relaxivity-iron calibration. The predicted R2* and single spin echo R2 increased by a factor of 2.00 and 1.51, respectively, at 1.5 versus 3.0 T. MSE signals and their corresponding R2 depended strongly on LIC, interecho time, and field strength. Preliminary results showed that a nonmonoexponential model accurately characterizes the simulated MSE signals, and that strong correlations were found between predicted relaxation parameters and LIC. In conclusion, relaxivity-iron calibration is reproducible using the proposed Monte Carlo model. Furthermore, this model can be readily extended to other important applications, including predicting signal behavior for MSE imaging.


Assuntos
Sobrecarga de Ferro/metabolismo , Ferro/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética/métodos , Método de Monte Carlo , Calibragem , Humanos , Sobrecarga de Ferro/diagnóstico por imagem , Reprodutibilidade dos Testes
6.
Eur Radiol ; 30(11): 6003-6013, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32588209

RESUMO

OBJECTIVES: The primary objective was to compare the performance of 3 different abbreviated MRI (AMRI) sets extracted from a complete gadoxetate-enhanced MRI obtained for hepatocellular carcinoma (HCC) screening. Secondary objective was to perform a preliminary cost-effectiveness analysis, comparing each AMRI set to published ultrasound performance for HCC screening in the USA. METHODS: This retrospective study included 237 consecutive patients (M/F, 146/91; mean age, 58 years) with chronic liver disease who underwent a complete gadoxetate-enhanced MRI for HCC screening in 2017 in a single institution. Two radiologists independently reviewed 3 AMRI sets extracted from the complete exam: non-contrast (NC-AMRI: T2-weighted imaging (T2wi)+diffusion-weighted imaging (DWI)), dynamic-AMRI (Dyn-AMRI: T2wi+DWI+dynamic T1wi), and hepatobiliary phase AMRI (HBP-AMRI: T2wi+DWI+T1wi during the HBP). Each patient was classified as HCC-positive/HCC-negative based on the reference standard, which consisted in all available patient data. Diagnostic performance for HCC detection was compared between sets. Estimated set characteristics, including historical ultrasound data, were incorporated into a microsimulation model for cost-effectiveness analysis. RESULTS: The reference standard identified 13/237 patients with HCC (prevalence, 5.5%; mean size, 33.7 ± 30 mm). Pooled sensitivities were 61.5% for NC-AMRI (95% confidence intervals, 34.4-83%), 84.6% for Dyn-AMRI (60.8-95.1%), and 80.8% for HBP-AMRI (53.6-93.9%), without difference between sets (p range, 0.06-0.16). Pooled specificities were 95.5% (92.4-97.4%), 99.8% (98.4-100%), and 94.9% (91.6-96.9%), respectively, with a significant difference between Dyn-AMRI and the other sets (p < 0.01). All AMRI methods were effective compared with ultrasound, with life-year gain of 3-12 months against incremental costs of US$ < 12,000. CONCLUSIONS: NC-AMRI has limited sensitivity for HCC detection, while HBP-AMRI and Dyn-AMRI showed excellent sensitivity and specificity, the latter being slightly higher for Dyn-AMRI. Cost-effectiveness estimates showed that AMRI is effective compared with ultrasound. KEY POINTS: • Comparison of different abbreviated MRI (AMRI) sets reconstructed from a complete gadoxetate MRI demonstrated that non-contrast AMRI has low sensitivity (61.5%) compared with contrast-enhanced AMRI (80.8% for hepatobiliary phase AMRI and 84.6% for dynamic AMRI), with all sets having high specificity. • Non-contrast and hepatobiliary phase AMRI can be performed in less than 14 min (including set-up time), while dynamic AMRI can be performed in less than 17 min. • All AMRI sets were cost-effective for HCC screening in at-risk population in comparison with ultrasound.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/complicações , Doença Crônica , Meios de Contraste , Análise Custo-Benefício , Imagem de Difusão por Ressonância Magnética/economia , Imagem de Difusão por Ressonância Magnética/métodos , Detecção Precoce de Câncer/métodos , Feminino , Gadolínio DTPA , Humanos , Hepatopatias , Neoplasias Hepáticas/complicações , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
7.
Magn Reson Med ; 83(2): 673-680, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31423637

RESUMO

PURPOSE: Determine the impact of the microscopic spatial distribution of iron on relaxometry and susceptibility-based estimates of iron concentration. METHODS: Monte Carlo simulations and in vitro experiments of erythrocytes were used to create different microscopic distributions of iron. Measuring iron with intact erythrocyte cells created a heterogeneous distribution of iron, whereas lysing erythrocytes was used to create a homogeneous distribution of iron. Multi-echo spin echo and spoiled gradient echo acquisitions were then used to estimate relaxation parameters ( R2 and R2* ) and susceptibility. RESULTS: Simulations demonstrate that R2 and R2* measurements depend on the spatial distribution of iron even for the same iron concentration and volume susceptibility. Similarly, in vitro experiments demonstrate that R2 and R2* measurements depend on the microscopic spatial distribution of iron whereas the quantitative susceptibility mapping (QSM) susceptibility estimates reflect iron concentration without sensitivity to spatial distribution. CONCLUSIONS: R2 and R2* for iron quantification depend on the spatial distribution or iron. QSM-based estimation of iron concentration is insensitive to the microscopic spatial distribution of iron, potentially providing a distribution independent measure of iron concentration.


Assuntos
Ferro/metabolismo , Imageamento por Ressonância Magnética , Microscopia , Algoritmos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Meios de Contraste/química , Membrana Eritrocítica/metabolismo , Eritrócitos/citologia , Eritrócitos/metabolismo , Compostos Férricos/química , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Sobrecarga de Ferro , Fígado/diagnóstico por imagem , Método de Monte Carlo
8.
J Magn Reson Imaging ; 49(1): 229-238, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29707848

RESUMO

BACKGROUND: Improving the signal-to-noise ratio (SNR) of chemical-shift-encoded MRI acquisition with complex reconstruction (MRI-C) may improve the accuracy and precision of noninvasive proton density fat fraction (PDFF) quantification in patients with hepatic steatosis. PURPOSE: To assess the accuracy of high SNR (Hi-SNR) MRI-C versus standard MRI-C acquisition to estimate hepatic PDFF in adult and pediatric nonalcoholic fatty liver disease (NAFLD) using an MR spectroscopy (MRS) sequence as the reference standard. STUDY TYPE: Prospective. POPULATION/SUBJECTS: In all, 231 adult and pediatric patients with known or suspected NAFLD. FIELD STRENGTH/SEQUENCE: PDFF estimated at 3T by three MR techniques: standard MRI-C; a Hi-SNR MRI-C variant with increased slice thickness, decreased matrix size, and no parallel imaging; and MRS (reference standard). ASSESSMENT: MRI-PDFF was measured by image analysts using a region of interest coregistered with the MRS-PDFF voxel. STATISTICAL TESTS: Linear regression analyses were used to assess accuracy and precision of MRI-estimated PDFF for MRS-PDFF as a function of MRI-PDFF using the standard and Hi-SNR MRI-C for all patients and for patients with MRS-PDFF <10%. RESULTS: In all, 271 exams from 231 patients were included (mean MRS-PDFF: 12.6% [SD: 10.4]; range: 0.9-41.9). High agreement between MRI-PDFF and MRS-PDFF was demonstrated across the overall range of PDFF, with a regression slope of 1.035 for the standard MRI-C and 1.008 for Hi-SNR MRI-C. Hi-SNR MRI-C, compared to standard MRI-C, provided small but statistically significant improvements in the slope (respectively, 1.008 vs. 1.035, P = 0.004) and mean bias (0.412 vs. 0.673, P < 0.0001) overall. In the low-fat patients only, Hi-SNR MRI-C provided improvements in the slope (1.058 vs. 1.190, P = 0.002), mean bias (0.168 vs. 0.368, P = 0.007), intercept (-0.153 vs. -0.796, P < 0.0001), and borderline improvement in the R2 (0.888 vs. 0.813, P = 0.01). DATA CONCLUSION: Compared to standard MRI-C, Hi-SNR MRI-C provides slightly higher MRI-PDFF estimation accuracy across the overall range of PDFF and improves both accuracy and precision in the low PDFF range. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:229-238.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Razão Sinal-Ruído , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Adulto Jovem
9.
Hepatology ; 68(2): 763-772, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29356032

RESUMO

Nonalcoholic fatty liver disease (NAFLD) is currently the most common cause of chronic liver disease worldwide, and the progressive form of this condition, nonalcoholic steatohepatitis (NASH), has become one of the leading indications for liver transplantation. Despite intensive investigations, there are currently no United States Food and Drug Administration-approved therapies for treating NASH. A major barrier for drug development in NASH is that treatment response assessment continues to require liver biopsy, which is invasive and interpreted subjectively. Therefore, there is a major unmet need for developing noninvasive, objective, and quantitative biomarkers for diagnosis and assessment of treatment response. Emerging data support the use of magnetic resonance imaging-derived proton density fat fraction (MRI-PDFF) as a noninvasive, quantitative, and accurate measure of liver fat content to assess treatment response in early-phase NASH trials. In this review, we discuss the role and utility, including potential sample size reduction, of MRI-PDFF as a quantitative and noninvasive imaging-based biomarker in early-phase NASH trials. Nonalcoholic fatty liver disease (NAFLD) is currently the most common cause of chronic liver disease worldwide.() NAFLD can be broadly classified into two categories: nonalcoholic fatty liver, which has a minimal risk of progression to cirrhosis, and nonalcoholic steatohepatitis (NASH), the more progressive form of NAFLD, which has a significantly increased risk of progression to cirrhosis.() Over the past two decades, NASH-related cirrhosis has become the second leading indication for liver transplantation in the United States.() For these reasons, pharmacological therapy for NASH is needed urgently. Despite intensive investigations, there are currently no therapies for treating NASH that have been approved by the United States Food and Drug Administration.().


Assuntos
Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Biomarcadores , Ensaios Clínicos como Assunto , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/patologia
11.
J Magn Reson Imaging ; 35(5): 1216-21, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22247050

RESUMO

PURPOSE: To develop a robust T(2) -weighted volumetric imaging technique with uniform water-silicone separation and simultaneous fat suppression for rapid assessment of breast implants in a single acquisition. MATERIALS AND METHODS: A three-dimensional (3D) fast spin echo sequence that uses variable refocusing flip angles was combined with a three-point chemical-shift technique (IDEAL) and short tau inversion recovery (STIR). Phase shifts of -π/6, +π/2, and +7π/6 between water and silicone were used for IDEAL processing. For comparison, two-dimensional images using 2D-FSE-IDEAL with STIR were also acquired in axial, coronal, and sagittal orientations. RESULTS: Near-isotropic (true spatial resolution-0.9 × 1.3 × 2.0 mm(3) ) volumetric breast images with uniform water-silicone separation and simultaneous fat suppression were acquired successfully in clinically feasible scan times (7:00-10:00 min). The 2D images were acquired with the same in-plane resolution (0.9 × 1.3 mm(2) ), but the slice thickness was increased to 6 mm with a slice gap of 1 mm for complete coverage of the implants in a reasonable scan time, which varied between 18:00 and 22:30 min. CONCLUSION: The single volumetric acquisition with uniform water and silicone separation enables images to be reformatted into any orientation. This allows comprehensive assessment of breast implant integrity in less than 10 min of total examination time.


Assuntos
Implantes de Mama , Mama/anatomia & histologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/anatomia & histologia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Géis de Silicone , Água
12.
Magn Reson Med ; 67(2): 389-404, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21661045

RESUMO

Nonalcoholic fatty liver disease is the most prevalent chronic liver disease in Western societies. MRI can quantify liver fat, the hallmark feature of nonalcoholic fatty liver disease, so long as multiple confounding factors including T(2)* decay are addressed. Recently developed MRI methods that correct for T(2)* to improve the accuracy of fat quantification either assume a common T(2)* (single-T(2)*) for better stability and noise performance or independently estimate the T(2)* for water and fat (dual-T(2)*) for reduced bias, but with noise performance penalty. In this study, the tradeoff between bias and variance for different T(2)* correction methods is analyzed using the Cramér-Rao bound analysis for biased estimators and is validated using Monte Carlo experiments. A noise performance metric for estimation of fat fraction is proposed. Cramér-Rao bound analysis for biased estimators was used to compute the metric at different echo combinations. Optimization was performed for six echoes and typical T(2)* values. This analysis showed that all methods have better noise performance with very short first echo times and echo spacing of ∼π/2 for single-T(2)* correction, and ∼2π/3 for dual-T(2)* correction. Interestingly, when an echo spacing and first echo shift of ∼π/2 are used, methods without T(2)* correction have less than 5% bias in the estimates of fat fraction.


Assuntos
Algoritmos , Fígado Gorduroso/diagnóstico , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Gordura Intra-Abdominal/patologia , Imageamento por Ressonância Magnética/métodos , Artefatos , Imagem Ecoplanar/métodos , Hemossiderose/diagnóstico , Humanos , Fígado/patologia , Modelos Teóricos , Método de Monte Carlo , Sensibilidade e Especificidade , Design de Software
13.
J Magn Reson Imaging ; 34(4): 729-749, 2011 10.
Artigo em Inglês | MEDLINE | ID: mdl-22025886

RESUMO

Hepatic steatosis is characterized by abnormal and excessive accumulation of lipids within hepatocytes. It is an important feature of diffuse liver disease, and the histological hallmark of non-alcoholic fatty liver disease (NAFLD). Other conditions associated with steatosis include alcoholic liver disease, viral hepatitis, HIV and genetic lipodystrophies, cystic fibrosis liver disease, and hepatotoxicity from various therapeutic agents. Liver biopsy, the current clinical gold standard for assessment of liver fat, is invasive and has sampling errors, and is not optimal for screening, monitoring, clinical decision making, or well-suited for many types of research studies. Non-invasive methods that accurately and objectively quantify liver fat are needed. Ultrasound (US) and computed tomography (CT) can be used to assess liver fat but have limited accuracy as well as other limitations. Magnetic resonance (MR) techniques can decompose the liver signal into its fat and water signal components and therefore assess liver fat more directly than CT or US. Most magnetic resonance (MR) techniques measure the signal fat-fraction (the fraction of the liver MR signal attributable to liver fat), which may be confounded by numerous technical and biological factors and may not reliably reflect fat content. By addressing the factors that confound the signal fat-fraction, advanced MR techniques measure the proton density fat-fraction (the fraction of the liver proton density attributable to liver fat), which is a fundamental tissue property and a direct measure of liver fat content. These advanced techniques show promise for accurate fat quantification and are likely to be commercially available soon.

14.
Radiology ; 261(1): 266-73, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21813739

RESUMO

PURPOSE: To compare noninvasive transstenotic pressure gradient (TSPG) measurements derived from high-spatial- and temporal-resolution four-dimensional magnetic resonance (MR) flow measurements with invasive measurements obtained from endovascular pressure wires with digital subtraction angiographic guidance. MATERIALS AND METHODS: After Animal Care and Use Committee approval, bilateral renal artery stenosis (RAS) was created surgically in 12 swine. Respiratory-gated phase-contrast vastly undersampled isotropic projection (VIPR) MR angiography of the renal arteries was performed with a 1.5-T clinical MR system (repetition time, 11.4 msec; echo time [first echo], 3.7 msec; 18,000 projection angles; imaging volume, 260 × 260 × 200 mm; acquired isotropic spatial resolution, 1.0 × 1.0 × 1.0 mm; velocity encoding, 150 cm/sec). Velocities measured with phase-contrast VIPR were used to calculate TSPGs by using Navier-Stokes equations. These were compared with endovascular pressure measurements (mean and peak) performed by using fluoroscopic guidance with regression analysis. RESULTS: In 19 renal arteries with an average stenosis of 62% (range, 0%-87%), there was excellent correlation between the noninvasive TSPG measurement with phase-contrast VIPR and invasive TSPG measurement for mean TSPG (R² = 95.4%) and strong correlation between noninvasive TSPG and invasive TSPG for the peak TSPG measures (R² = 82.6%). The phase-contrast VIPR-derived TSPG measures were slightly lower than the endovascular measurements. In four arteries with severe stenoses and one occlusion (mean, 86%; range, 75%-100%), the residual lumen within the stenosis was too small to determine TSPG with phase-contrast VIPR. CONCLUSION: The unenhanced MR angiographic technique with phase-contrast VIPR allows for accurate noninvasive assessment of hemodynamic significance in a porcine model of RAS with highly accurate TSPG measurements.


Assuntos
Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/fisiopatologia , Animais , Radiografia , Suínos
15.
J Magn Reson Imaging ; 32(1): 173-83, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20578024

RESUMO

PURPOSE: To compare six new three-dimensional (3D) magnetic resonance (MR) methods for evaluating knee cartilage at 3.0T. MATERIALS AND METHODS: We compared: fast-spin-echo cube (FSE-Cube), vastly undersampled isotropic projection reconstruction balanced steady-state free precession (VIPR-bSSFP), iterative decomposition of water and fat with echo asymmetry and least-squares estimation combined with spoiled gradient echo (IDEAL-SPGR) and gradient echo (IDEAL-GRASS), multiecho in steady-state acquisition (MENSA), and coherent oscillatory state acquisition for manipulation of image contrast (COSMIC). Five-minute sequences were performed twice on 10 healthy volunteers and once on five osteoarthritis (OA) patients. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured from the volunteers. Images of the five volunteers and the five OA patients were ranked on tissue contrast, articular surface clarity, reformat quality, and lesion conspicuity. FSE-Cube and VIPR-bSSFP were compared to IDEAL-SPGR for cartilage volume measurements. RESULTS: FSE-Cube had top rankings for lesion conspicuity, overall SNR, and CNR (P < 0.02). VIPR-bSSFP had top rankings in tissue contrast and articular surface clarity. VIPR and FSE-Cube tied for best in reformatting ability. FSE-Cube and VIPR-bSSFP compared favorably to IDEAL-SPGR in accuracy and precision of cartilage volume measurements. CONCLUSION: FSE-Cube and VIPR-bSSFP produce high image quality with accurate volume measurement of knee cartilage.


Assuntos
Cartilagem Articular/anatomia & histologia , Imageamento Tridimensional/métodos , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
16.
Radiology ; 252(2): 561-7, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19528355

RESUMO

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. The purpose was to prospectively compare multiecho iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) gradient-echo (GRE) magnetic resonance (MR) imaging with three-dimensional fat-suppressed (FS) spoiled GRE (SPGR) MR imaging to evaluate the articular cartilage of the knee. Six healthy volunteer and 10 cadaver knees were imaged at 1.5 T. Signal-to-noise ratio (SNR), SNR efficiency, and cartilage volume were measured. SNR and SNR efficiency were significantly higher with multiecho IDEAL GRE than with FS SPGR imaging (P < .031). Both methods produced equivalent cartilage volumes (overall concordance correlation coefficient, 0.998) with high precision and accuracy. The use of a cartilage phantom confirmed high accuracy in volume measurements and high reproducibility for both methods. Multiecho IDEAL GRE provides high signal intensity in cartilage and synovial fluid and is a promising technique for imaging articular cartilage of the knee.


Assuntos
Tecido Adiposo/patologia , Água Corporal , Cartilagem Articular/patologia , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Articulação do Joelho/patologia , Osteoartrite do Joelho/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Água
17.
AJR Am J Roentgenol ; 193(1): 14-27, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19542391

RESUMO

OBJECTIVE: With recent advances in technology, advanced MRI methods such as diffusion-weighted and perfusion-weighted MRI, MR elastography, chemical shift-based fat-water separation, and MR spectroscopy can now be applied to liver imaging. We will review the respective roles of these techniques for assessment of chronic liver disease. CONCLUSION: MRI plays an increasingly important role in assessment of patients with chronic liver disease because of the lack of ionizing radiation and the possibility of performing multiparametric imaging.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Hepatopatias/diagnóstico , Fígado/patologia , Adulto , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Med Phys ; 35(8): 3597-606, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18777920

RESUMO

Separation of water from fat tissues in magnetic resonance imaging is important for many applications because signals from fat tissues often interfere with diagnoses that are usually based on water signal characteristics. Water and fat can be separated with images acquired at different echo time shifts. The three-point method solves for the unknown off-resonance frequency together with the water and fat densities. Noise performance of the method, quantified by the effective number of signals averaged (NSA), is an important metric of the water and fat images. The authors use error propagation theory and Monte Carlo simulation to investigate two common reconstructive approaches: an analytic-solution based estimation and a least-squares estimation. Two water-fat chemical shift (CS) encoding strategies, the symmetric (-theta, 0, theta) and the shifted (0, theta, 2theta) schemes are studied and compared. Results show that NSAs of water and fat can be different and they are dependent on the ratio of intensities of the two species and each of the echo time shifts. The NSA is particularly poor for the symmetric (-theta, 0, theta) CS encoding when the water and fat signals are comparable. This anomaly with equal amounts of water and fat is analyzed in a more intuitive geometric illustration. Theoretical prediction of NSA matches well with simulation results at high signal-to-noise ratio (SNR), while deviation arises at low SNR, which suggests that Monte Carlo simulation may be more appropriate to accurately predict noise performance of the algorithm when SNR is low.


Assuntos
Tecido Adiposo/anatomia & histologia , Artefatos , Água Corporal , Diagnóstico por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Ruído
19.
Magn Reson Med ; 58(2): 354-64, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17654578

RESUMO

Quantification of hepatic steatosis is a significant unmet need for the diagnosis and treatment of patients with nonalcoholic fatty liver disease (NAFLD). MRI is capable of separating water and fat signals in order to quantify fatty infiltration of the liver (hepatic steatosis). Unfortunately, fat signal has confounding T(1) effects and the nonzero mean noise in low signal-to-noise ratio (SNR) magnitude images can lead to incorrect estimation of the true lipid percentage. In this study, the effects of bias from T(1) effects and image noise were investigated. An oil/water phantom with volume fat-fractions ranging linearly from 0% to 100% was designed and validated using a spoiled gradient echo (SPGR) sequence in combination with a chemical-shift based fat-water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL). We demonstrated two approaches to reduce the effects of T(1): small flip angle (flip angle) and dual flip angle methods. Both methods were shown to effectively minimize deviation of the measured fat-fraction from its true value. We also demonstrated two methods to reduce noise bias: magnitude discrimination and phase-constrained reconstruction. Both methods were shown to reduce this noise bias effectively from 15% to less than 1%.


Assuntos
Fígado Gorduroso/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo
20.
Invest Radiol ; 41(2): 148-53, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16428986

RESUMO

PURPOSE: The aim of the current study was to show if contrast-to-noise ratio (CNR) could be improved without loss of diagnostic accuracy if a phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence is used at 3.0 T instead of 1.5 T. MATERIAL AND METHODS: Ten patients with myocardial infarction were examined on a 1.5 T magnetic resonance (MR) system (Avanto, Siemens Medical Systems) and at a 3.0 T MR system. Imaging delayed contrast enhancement was started 10 minutes after application of contrast material. A phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence was used at 1.5 and 3.0 T and compared with a segmented IR turboFLASH sequence at 1.5 T, which served as the reference method. Infarct volumes and CNR of infarction and normal myocardium were compared with the reference method. RESULTS: The PSIR Single-Shot TrueFISP technique allows for imaging nine slices during a single breathhold without adaptation of the inversion time. The mean value of CNR between infarction and normal myocardium was 5.9 at 1.5 T and 12.2 at 3.0 T (magnitude images). The CNR mean value of the reference method was 8.4. The CNR mean value at 3.0 T was significantly (P = 0.03) higher than the mean value of the reference method. The correlation coefficients of the infarct volumes, determined with the PSIR single-shot TrueFISP technique at 1.5 T and at 3.0 T and compared with the reference method, were r = 0.96 (P = 0.001) and r = 0.99 (P = 0.0001). CONCLUSION: The use of PSIR single-shot TrueFISP at 3.0 T allows for accurate detection and assessment of myocardial infarction. CNR is significantly higher at 3.0 T compared with 1.5 T. The PSIR single-shot technique at 3.0 T provides a higher CNR than the segmented reference technique at 1.5 T.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Adulto , Idoso , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA