Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiology ; 305(2): 329-338, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35880980

RESUMO

Background The relationship between papillary muscle infarction (papMI) and the culprit coronary lesion has not been fully investigated. Delayed enhancement cardiac MRI may detect papMI, yet its accuracy is unknown. Flow-independent dark-blood delayed enhancement (FIDDLE) cardiac MRI has been shown to improve the detection of myocardial infarction adjacent to blood pool. Purpose To assess the diagnostic performance of delayed enhancement and FIDDLE cardiac MRI for the detection of papMI, and to investigate the prevalence of papMI and its relationship to the location of the culprit coronary lesion. Materials and Methods A prospective canine study was used to determine the accuracy of conventional delayed enhancement imaging and FIDDLE imaging for detection of papMI, with pathology-based findings as the reference standard. Participants with first-time myocardial infarction with a clear culprit lesion at coronary angiography were prospectively enrolled at a single hospital from 2015 to 2018 and compared against control participants with low Framingham risk scores. In canines, diagnostic accuracy was calculated for delayed enhancement and FIDDLE imaging. Results In canines (n = 27), FIDDLE imaging was more sensitive (100% [23 of 23] vs 57% [13 of 23], P < .001) and accurate (100% [54 of 54] vs 80% [43 of 54], P = .01) than delayed enhancement imaging for detection of papMI. In 43 participants with myocardial infarction (mean age, 56 years ± 16 [SD]; 28 men), the infarct-related artery was the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and right coronary artery in 47% (20 of 43), 26% (11 of 43), and 28% (12 of 43), respectively. The prevalence of anterior papMI was lower than posterior papMI (37% [16 of 43 participants] vs 44% [19 of 43 participants]) despite more LAD culprit lesions. Culprits leading to papMI were restricted to a smaller "at-risk" portion of the coronary tree for anterior papMI (subtended first diagonal branch of the LAD or first marginal branch of the LCX) compared with posterior (subtended posterior descending artery or third obtuse marginal branch of the LCX). Culprits within these at-risk portions were predictive of papMI at a similar rate (anterior, 83% [15 of 18 participants] vs posterior, 86% [18 of 21 participants]). Conclusion Flow-independent dark-blood delayed enhancement cardiac MRI, unlike conventional delayed enhancement cardiac MRI, was highly accurate in the detection of papillary muscle infarction (papMI). Anterior papMI was less prevalent than posterior papMI, most likely due to culprit lesions being restricted to a smaller portion of the coronary tree rather than because of redundant, dual vascular supply. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Kawel-Boehm and Bremerich in this issue.


Assuntos
Infarto do Miocárdio , Músculos Papilares , Masculino , Humanos , Cães , Animais , Pessoa de Meia-Idade , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/patologia , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico por imagem , Vasos Coronários/patologia , Angiografia Coronária/efeitos adversos , Infarto , Imageamento por Ressonância Magnética/efeitos adversos
2.
Eur Radiol ; 26(4): 951-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26188657

RESUMO

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.


Assuntos
Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Meios de Contraste , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Estudos Prospectivos
3.
Acta Cardiol ; 66(3): 349-57, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21744705

RESUMO

OBJECTIVE: Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). METHODS AND RESULTS: 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). CONCLUSIONS: Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Músculos Papilares/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Diástole/fisiologia , Feminino , Coração/fisiopatologia , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Sístole/fisiologia
4.
Nat Clin Pract Cardiovasc Med ; 2(3): 150-8, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16265459

RESUMO

Myocardial viability is of established importance to the management of cardiac patients being considered for revascularization. Existing noninvasive imaging tests to examine myocardial viability, such as stress echocardiography and nuclear scintigraphy, are of recognized utility but are subject to intrinsic limitations. Over the past few years delayed-enhancement MRI (DE-MRI) has emerged as an alternative to traditional tests and for the first time allows direct visualization of the transmural extent of myocardial viability. In this paper we review the scientific data that underlie the use of DE-MRI in patients with ischemic heart disease. Progress in this area is largely the result of the development of a new MRI pulse sequence in the late 1990s, which improved the detection of necrotic and scarred myocardial tissue. Following this technical development, a series of detailed histologic comparisons in large animal models revealed that both acute and healed myocardial infarcts appeared as brighter (hyperenhanced) areas than viable regions, and that the effect is independent of contractile function. The resulting 'bright is dead' hypothesis has thus far proven of significant use in patients with ischemic heart disease. Data are now emerging which suggest that the DE-MRI technique also has important implications for patients with nonischemic forms of cardiomyopathy.


Assuntos
Aumento da Imagem , Imageamento por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Miocárdio/patologia , Meios de Contraste , Humanos , Contração Miocárdica/fisiologia , Isquemia Miocárdica/fisiopatologia
5.
Circulation ; 111(8): 1033-9, 2005 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-15723978

RESUMO

BACKGROUND: Magnetic resonance global coherent free precession (GCFP) is a new technique that produces cine projection angiograms directly analogous to those of x-ray angiography noninvasively and without a contrast agent. In this study, we compared GCFP blood flow with "gold standards" to determine the accuracy of noninvasive GCFP blood flow measurements. METHODS AND RESULTS: The relationship between GCFP blood flow and true blood flow defined by invasive ultrasonic flow probe and by phase contrast velocity encoded MRI (VENC) was studied in anesthetized dogs (n=6). Blood flow was controlled by use of a hydraulic occluder around the left iliac artery. GCFP images were acquired by selectively exciting the abdominal aorta and visualizing temporal blood flow into the iliac arteries. GCFP flow was similar to ultrasonic blood flow at baseline (131.3+/-44.8 versus 114.8+/-34.2 mL/min), during occlusion (10.8+/-5.1 versus 6.5+/-7.2 mL/min), during reactive hyperemia (191.4+/-100.7 versus 260.3+/-138.7 mL/min), during the new resting state (135.5+/-52.4 versus 117.8+/-24.1 mL/min), and during partial occlusion (61.4+/-36.4 versus 49.3+/-13.1 mL/min, P=NS for all). Results comparing GCFP flow with VENC were similar. Statistical analysis revealed that GCFP flow was related to mean blood flow assessed by the flow probe (P<0.0001) and by VENC (P<0.0001). In the control right iliac artery, conversely, GCFP measurements were unaffected throughout all left iliac interventions (P=NS). CONCLUSIONS: GCFP blood flow is linearly related to true blood flow for a straight, cylindrical blood vessel without branches. Although more complex geometries imply a qualitative rather than a quantitative relationship, the data nevertheless suggest that GCFP may serve as the basis for a new form of noninvasive stress testing.


Assuntos
Imagem Cinética por Ressonância Magnética/tendências , Fluxo Sanguíneo Regional/fisiologia , Animais , Cães , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Sonda Molecular
SELEÇÃO DE REFERÊNCIAS