Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258308

RESUMO

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Assuntos
Anti-Infecciosos , Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Antibacterianos/uso terapêutico , Fatores de Risco , Eletrônica , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
2.
Circ Cardiovasc Qual Outcomes ; 17(1): e010533, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37929587

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently undertaken in patients with ischemic left ventricular systolic dysfunction. The REVIVED (Revascularization for Ischemic Ventricular Dysfunction)-BCIS2 (British Cardiovascular Society-2) trial concluded that PCI did not reduce the incidence of all-cause death or heart failure hospitalization; however, patients assigned to PCI reported better initial health-related quality of life than those assigned to optimal medical therapy (OMT) alone. The aim of this study was to assess the cost-effectiveness of PCI+OMT compared with OMT alone. METHODS: REVIVED-BCIS2 was a prospective, multicenter UK trial, which randomized patients with severe ischemic left ventricular systolic dysfunction to either PCI+OMT or OMT alone. Health care resource use (including planned and unplanned revascularizations, medication, device implantation, and heart failure hospitalizations) and health outcomes data (EuroQol 5-dimension 5-level questionnaire) on each patient were collected at baseline and up to 8 years post-randomization. Resource use was costed using publicly available national unit costs. Within the trial, mean total costs and quality-adjusted life-years (QALYs) were estimated from the perspective of the UK health system. Cost-effectiveness was evaluated using estimated mean costs and QALYs in both groups. Regression analysis was used to adjust for clinically relevant predictors. RESULTS: Between 2013 and 2020, 700 patients were recruited (mean age: PCI+OMT=70 years, OMT=68 years; male (%): PCI+OMT=87, OMT=88); median follow-up was 3.4 years. Over all follow-ups, patients undergoing PCI yielded similar health benefits at higher costs compared with OMT alone (PCI+OMT: 4.14 QALYs, £22 352; OMT alone: 4.16 QALYs, £15 569; difference: -0.015, £6782). For both groups, most health resource consumption occurred in the first 2 years post-randomization. Probabilistic results showed that the probability of PCI being cost-effective was 0. CONCLUSIONS: A minimal difference in total QALYs was identified between arms, and PCI+OMT was not cost-effective compared with OMT, given its additional cost. A strategy of routine PCI to treat ischemic left ventricular systolic dysfunction does not seem to be a justifiable use of health care resources in the United Kingdom. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01920048.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Intervenção Coronária Percutânea , Disfunção Ventricular Esquerda , Idoso , Humanos , Masculino , Doença da Artéria Coronariana/terapia , Análise de Custo-Efetividade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Feminino
3.
medRxiv ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106113

RESUMO

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

4.
J Cardiovasc Electrophysiol ; 34(12): 2590-2598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37814470

RESUMO

BACKGROUND: The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system is a novel technology used to treat patients with dyssynchronous heart failure (HF) by providing leadless cardiac resynchronization therapy (CRT). Observational studies have demonstrated its safety and efficacy profile, however, the treatment cost-effectiveness has not previously been examined. METHODS: A cost-effectiveness evaluation of the WiSE-CRT System was performed using a cohort-based economic model adopting a "proportion in state" structure. In addition to the primary analysis, scenario analyses and sensitivity analyses were performed to test for uncertainty in input parameters. Outcomes were quantified in terms of quality-adjusted life year (QALY) differences. RESULTS: The primary analysis demonstrated that treatment with the WiSE-CRT system is likely to be cost-effective over a lifetime horizon at a QALY reimbursement threshold of £20 000, with a net monetary benefit (NMB) of £3781 per QALY. Cost-effectiveness declines at time horizons shorter than 10 years. Sensitivity analyses demonstrated that average system battery life had the largest impact on potential cost-effectiveness. CONCLUSION: Within the model limitations, these findings support the use of WiSE-CRT in indicated patients from an economic standpoint. However, improving battery technology should be prioritized to maximize cost-effectiveness in times when health services are under significant financial pressures.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/economia , Análise de Custo-Efetividade , Insuficiência Cardíaca/terapia , Resultado do Tratamento
5.
Comput Biol Med ; 139: 104987, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34741904

RESUMO

The implanted cardioverter defibrillator (ICD) is an effective direct therapy for the treatment of cardiac arrhythmias, including ventricular tachycardia (VT). Anti-tachycardia pacing (ATP) is often applied by the ICD as the first mode of therapy, but is often found to be ineffective, particularly for fast VTs. In such cases, strong, painful and damaging backup defibrillation shocks are applied by the device. Here, we propose two novel electrode configurations: "bipolar" and "transmural" which both combine the concept of targeted shock delivery with the advantage of reduced energy required for VT termination. We perform an in silico study to evaluate the efficacy of VT termination by applying one single (low-energy) monophasic shock from each novel configuration, comparing with conventional ATP therapy. Both bipolar and transmural configurations are able to achieve a higher efficacy (93% and 85%) than ATP (45%), with energy delivered similar to and two orders of magnitudes smaller than conventional ICD defibrillation shocks, respectively. Specifically, the transmural configuration (which applies the shock vector directly across the scar substrate sustaining the VT) is most efficient, requiring typically less than 1 J shock energy to achieve a high efficacy. The efficacy of both bipolar and transmural configurations are higher when applied to slow VTs (100% and 97%) compared to fast VTs (57% and 29%). Both novel electrode configurations introduced are able to improve electrotherapy efficacy while reducing the overall number of required therapies and need for strong backup shocks.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Cardioversão Elétrica , Eletrocardiografia , Expiração , Humanos , Taquicardia Ventricular/terapia
6.
Int J Cardiol Heart Vasc ; 34: 100800, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34159251

RESUMO

BACKGROUND: Pre-procedural assessment of patients undergoing cardiac resynchronization therapy (CRT) is heterogenous and patients implanted with unfavorable characteristics may account for non-response. A dedicated CRT pre-assessment clinic (CRT PAC) was developed to standardize the review process and undertake structured pre-procedural evaluation. The aim of this analysis was to determine the effectiveness on patient selection and outcomes. METHODS: A prospective database of consecutive patients attending the CRT PAC between 2013 and 2018 was analyzed. Pre-operative assessment included cardiac magnetic resonance (CMR) and cardiopulmonary exercise testing (CPET). Patients were considered CRT responders based on improvement in clinical composite score (CCS) and/or reduction in left ventricular end-systolic volume (LVESV) ≥ 15% at 6-months follow-up. RESULTS: Of 252 patients reviewed in the CRT PAC during the analysis period, 192 fulfilled consensus guidelines for implantation. Of the patients receiving CRT, 82% showed improvement in their CCS and 57% had a reduction in LVESV ≥ 15%. The presence of subendocardial scar on CMR and a peak VO2 ≤ 12 ml/kg/min on CPET predicted CRT non-response. Two patients were unsuitable for CRT as they had end-stage heart failure and died during follow-up. The majority of patients initially deemed unsuitable for CRT did not suffer from unexpected hospitalization for decompensated heart failure or died from cardiovascular disease; only 8 patients (13%) received CRT devices during follow-up because of symptomatic left ventricular systolic impairment. CONCLUSION: A dedicated CRT PAC is able to appropriately select patients for CRT. Pre-procedural investigation/imaging can identify patients unlikely to respond to, or may not yet be suitable for CRT.

7.
Heart Rhythm O2 ; 2(1): 12-18, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34113900

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) produces acute changes in electric resynchronization that can be measured noninvasively with electrocardiographic body surface mapping (ECGi). The relation between baseline acute electrophysiology metrics and their manipulation with CRT and reverse remodeling is unclear. OBJECTIVE: To test (ECGi) derived parameters of electrical activation as predictors of volumetric response to CRT. METHODS: ECGi was performed in 21 patients directly following CRT implant. Activation parameters (left ventricular total activation time [LVtat], global biventricular total activation time [VVtat], global left/right ventricular electrical synchrony [VVsync], and global left ventricular dispersion of activation times [LVdisp]) were measured at baseline and following echocardiographically optimized CRT. Remodeling response (>15% reduction left ventricular end-systolic volume) was assessed 6 months post CRT. RESULTS: Patients were aged 68.9 ± 12.1 years, 81% were male, and 57% were ischemic. Baseline measures of dyssynchrony were more pronounced in left bundle branch block (LBBB) vs non-LBBB. ECGi demonstrated a trend of greater interventricular dyssynchrony between responders and nonresponders that did not reach statistical significance (VVsync: -45.7 ± 22.4 ms vs -25.1 ± 29.3 ms, P = .227). Remaining activation parameters were similar between responders and nonresponders (VVtat 101 ± 22.0 ms vs 98.9 ± 23.4 ms, P = .838; LVtat 86.4 ± 17.1 ms vs 85.1 ± 27.7 ms, P = .904; LVdisp 28.2 ± 6.3 ms vs 27.0 ± 8.7 ms, P = .726). In volumetric responders activation parameters were significantly improved with CRT compared to nonresponders: VV sync (-45.67 ± 22.41 ms vs 2.33±18.87 ms, P = .001), VVtat (101 ± 22.04 ms vs 71 ± 14.01 ms, P = .002), LVtat (86.44 ± 17.15 ms vs 67.67 ± 11.31 ms, P = .006), and LVdisp (28.22 ± 6.3 ms vs 21.56 ± 4.45 ms, P = .008). CONCLUSION: Baseline ECGi activation times did not predict CRT volumetric response. Volumetric responders exhibited significant improvements in ECGi-derived metrics with CRT. ECGi does not select CRT candidates but may be a useful adjunct to guide left ventricle lead implants and to perform postimplant CRT optimization.

8.
Heart ; 106(12): 931-937, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31932286

RESUMO

OBJECTIVES: Transvenous lead extraction (TLE) poses a significant economic and resource burden on healthcare systems; however, limited data exist on its true cost. We therefore estimate real-world healthcare reimbursement costs of TLE to the UK healthcare system at a single extraction centre. METHODS: Consecutive admissions entailing TLE at a high-volume UK centre between April 2013 and March 2018 were prospectively recorded in a computer registry. In the hospital's National Health Service (NHS) clinical coding/reimbursement database, 447 cases were identified. Mean reimbursement cost (n=445) and length of stay (n=447) were calculated. Ordinary least squares regressions estimated the relationship between cost (bed days) and clinical factors. RESULTS: Mean reimbursement cost per admission was £17 399.09±£13 966.49. Total reimbursement for all TLE admissions was £7 777 393.51. Mean length of stay was 16.3±15.16 days with a total of 7199 bed days. Implantable cardioverter-defibrillator and cardiac resynchronisation therapy defibrillator devices incurred higher reimbursement costs (70.5% and 68.7% higher, respectively, both p<0.001). Heart failure and prior valve surgery also incurred significantly higher reimbursement costs. Prior valve surgery and heart failure were associated with 8.3 (p=0.017) and 5.5 (p=0.021) additional days in hospital, respectively. CONCLUSIONS: Financial costs to the NHS from TLE are substantial. Consideration should therefore be given to cost/resource-sparing potential of leadless/extravascular cardiac devices that negate the need for TLE particularly in patients with prior valve surgery and/or heart failure. Additionally, use of antibiotic envelopes and other interventions that reduce infection risk in patients receiving transvenous leads should be considered.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/economia , Recursos em Saúde/economia , Custos Hospitalares , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Medicina Estatal/economia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Análise Custo-Benefício , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Reembolso de Seguro de Saúde , Tempo de Internação/economia , Londres , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/economia , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
9.
J Electrocardiol ; 51(4): 714-719, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29997019

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is now generally delivered via quadripolar leads. Assessment of the effect of different vector programs from quadripolar leads on ventricular activation can be now done using non-invasive electrocardiographic mapping (ECM). MATERIAL AND METHODS: In nineteen patients with quadripolar LV leads, activation maps were constructed. The total ventricular activation time (TVaT) and the time for the bulk of ventricular activation (VaT10-90) were calculated. RESULTS: CRT delivered via a quadripolar lead significantly reduced TVaT and VaT10-90 by a mean of 16 ms and 31 ms, respectively, compared to baseline. There was a marked reduction in ventricular activation between the most and least synchronous vectors: 28% difference in baseline TVaT and 37% difference in VaT10-90. CONCLUSION: Changes in the configuration of an LV quadripolar lead significantly affected ventricular activation timings in both ischaemic and non-ischaemic subjects. This suggests that programming of the optimal pacing vector may need to be individually tailored.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
Int J Cardiol ; 257: 131-136, 2018 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-29506684

RESUMO

AIMS: The 2014 National Institute of Clinical Excellence (NICE) guidelines on the management of acute heart failure recommended using a plasma NT-proBNP threshold of 300pg/ml to assist in ruling out the diagnosis of heart failure (HF), updating previous guidelines recommending using a threshold of 400pg/ml. NICE based their recommendations on 6 studies performed in other countries. This study sought to determine the diagnostic and economic implications of using these thresholds in a large unselected UK population. METHODS: Patient and clinical demographics were recorded for all consecutive suspected HF patients over 12months, as well as clinical outcomes including time to HF hospitalisation and time to death (follow up 15.8months). RESULTS: Of 1995 unselected patients admitted with clinically suspected HF, 1683 (84%) had a NTproBNP over the current NICE recommended threshold, of which 35% received a final diagnosis of HF. Lowering the threshold from 400 to 300pg/ml would have involved screening an additional 61 patients and only would have identified one new patient with HF (sensitivity 0.985, NPV 0.976, area under the curve (AUC) at 300pg/ml 0.67; sensitivity 0.983, NPV 0.977, AUC 0.65 at 400pg/ml). The economic implications of lowering the threshold would have involved additional costs of £42,842.04 (£702.33 per patient screened, or £ 42,824.04 per new HF patient). CONCLUSION: Applying the recent updated NICE guidelines to an unselected real world population increases the AUC but would have a significant economic impact and only identified one new patient with heart failure.


Assuntos
Análise Custo-Benefício/métodos , Insuficiência Cardíaca/economia , Hospitalização/economia , Peptídeo Natriurético Encefálico/economia , Fragmentos de Peptídeos/economia , Guias de Prática Clínica como Assunto/normas , Biomarcadores/sangue , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Hospitalização/tendências , Humanos , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Padrões de Referência
12.
Heart ; 104(5): 416-422, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28970277

RESUMO

OBJECTIVE: Responders to cardiac resynchronisation therapy whose device has a defibrillator component and who do not receive a therapy in the lifetime of the first generator have a very low incidence of appropriate therapy after box change. We investigated the cost implications of using a risk stratification tool at the time of generator change resulting in these patients being reimplanted with a resynchronisation pacemaker. METHODS: A decision tree was created using previously published data which had demonstrated an annualised appropriate defibrillator therapy risk of 2.33%. Costs were calculated at National Health Service (NHS) national tariff rates (2016-2017). EQ-5D utility values were applied to device reimplantations, admissions and mortality data, which were then used to estimate quality-adjusted life-years (QALYs) over 5 years. RESULTS: At 5 years, the incremental cost of replacing a resynchronisation defibrillator device with a second resynchronisation defibrillator versus resynchronisation pacemaker was £5045 per patient. Incremental QALY gained was 0.0165 (defibrillator vs pacemaker), resulting in an incremental cost-effectiveness ratio (ICER) of £305 712 per QALYs gained. Probabilistic sensitivity analysis resulted in an ICER of £313 612 (defibrillator vs pacemaker). For reimplantation of all patients with a defibrillator rather than a pacemaker to yield an ICER of less than £30 000 per QALY gained (current NHS cut-off for approval of treatment), the annual arrhythmic event rate would need to be 9.3%. The budget impact of selective replacement was a saving of £2 133 985 per year. CONCLUSIONS: Implanting low-risk patients with a resynchronisation defibrillator with the same device at the time of generator change is not cost-effective by current NHS criteria. Further research is required to understand the impact of these findings on individual patients at the time of generator change.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Fontes de Energia Elétrica/economia , Custos de Cuidados de Saúde , Disfunção Ventricular Esquerda/economia , Disfunção Ventricular Esquerda/terapia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Análise Custo-Benefício , Técnicas de Apoio para a Decisão , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/economia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
13.
J Magn Reson Imaging ; 33(1): 87-95, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21182125

RESUMO

PURPOSE: To evaluate a cardiac MR (CMR) examination with slow infusion of a high-relaxivity contrast agent to visualize coronary venous anatomy (CVA) and myocardial scar in heart failure patients awaiting cardiac resynchronization therapy (CRT). MATERIALS AND METHODS: Fourteen patients awaiting CRT (seven ischemic cardiomyopathy (ICM) and seven non-ICM) and two with normal LV function underwent CMR on a 1.5 Tesla (T) MR scanner. Dimeglumine-gadobenate was slowly infused. Bolus arrival in the LV was measured by a dynamic electrocardiogram (ECG) -triggered inversion recovery (IR) scan subsequent to starting an ECG-triggered respiratory-navigated three-dimensional (3D) SSFP MR scan with IR preparation to acquire systolic whole-heart anatomy for vein visualization. Delayed contrast-enhanced MR scan was performed to assess myocardial scar. CVA obtained by CMR was compared with X-ray venography in 11 patients. CVA and scar were segmented and registered for visual inspection. RESULTS: For all subjects, there was excellent visualization of the CVA. All ICM and one non-ICM patient showed scar. There was excellent correlation between veins seen by CMR and venography. CONCLUSION: We have demonstrated that slow infusion protocol of dimeglumine-gadobenate can be used to assess both CVA and myocardial scar in a single MR examination. Furthermore, an image overlay technique has been used to show the relationship of scar to the CVA.


Assuntos
Cardiomiopatias/patologia , Cicatriz/patologia , Anomalias dos Vasos Coronários/patologia , Gadolínio DTPA , Imagem Cinética por Ressonância Magnética/métodos , Veias/anormalidades , Veias/patologia , Terapia de Ressincronização Cardíaca , Meios de Contraste/administração & dosagem , Vasos Coronários , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Aumento da Imagem/métodos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA