Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Cell Mol Life Sci ; 81(1): 131, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38472405

RESUMO

The discoveries that cerebrospinal fluid participates in metabolic perivascular exchange with the brain and further drains solutes to meningeal lymphatic vessels have sparked a tremendous interest in translating these seminal findings from animals to humans. A potential two-way coupling between the brain extra-vascular compartment and the peripheral immune system has implications that exceed those concerning neurodegenerative diseases, but also imply that the central nervous system has pushed its immunological borders toward the periphery, where cross-talk mediated by cerebrospinal fluid may play a role in a range of neoplastic and immunological diseases. Due to its non-invasive approach, magnetic resonance imaging has typically been the preferred methodology in attempts to image the glymphatic system and meningeal lymphatics in humans. Even if flourishing, the research field is still in its cradle, and interpretations of imaging findings that topographically associate with reports from animals have yet seemed to downplay the presence of previously described anatomical constituents, particularly in the dura. In this brief review, we illuminate these challenges and assess the evidence for a glymphatic-lymphatic coupling. Finally, we provide a new perspective on how human brain and meningeal clearance function may possibly be measured in future.


Assuntos
Vasos Linfáticos , Animais , Humanos , Vasos Linfáticos/metabolismo , Sistema Nervoso Central , Encéfalo/fisiologia , Meninges/fisiologia , Imageamento por Ressonância Magnética
3.
JCI Insight ; 6(9)2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33822769

RESUMO

BACKGROUNDMethodology for estimation of cerebrospinal fluid (CSF) tracer clearance could have wide clinical application in predicting excretion of intrathecal drugs and metabolic solutes from brain metabolism and for diagnostic workup of CSF disturbances.METHODSThe MRI contrast agent gadobutrol (Gadovist) was used as a CSF tracer and injected into the lumbar CSF. Gadobutrol is contained outside blood vessels of the CNS and is eliminated along extravascular pathways, analogous to many CNS metabolites and intrathecal drugs. Tracer enrichment was verified and assessed in CSF by MRI at the level of the cisterna magna in parallel with obtaining blood samples through 48 hours.RESULTSIn a reference patient cohort (n = 29), both enrichment within CSF and blood coincided in time. Blood concentration profiles of gadobutrol through 48 hours varied between patients diagnosed with CSF leakage (n = 4), idiopathic normal pressure hydrocephalus dementia (n = 7), pineal cysts (n = 8), and idiopathic intracranial hypertension (n = 4).CONCLUSIONAssessment of CSF tracer clearance is clinically feasible and may provide a way to predict extravascular clearance of intrathecal drugs and endogenous metabolites from the CNS. The peak concentration in blood (at about 10 hours) was preceded by far peak tracer enhancement at MRI in extracranial lymphatic structures (at about 24 hours), as shown in previous studies, indicating a major role of the spinal canal in CSF clearance capacity.FUNDINGThe work was supported by the Department of Neurosurgery, Oslo University Hospital; the Norwegian Institute for Air Research; and the University of Oslo.


Assuntos
Cistos do Sistema Nervoso Central/metabolismo , Vazamento de Líquido Cefalorraquidiano/metabolismo , Meios de Contraste/farmacocinética , Sistema Glinfático/metabolismo , Hidrocefalia de Pressão Normal/metabolismo , Compostos Organometálicos/farmacocinética , Pseudotumor Cerebral/metabolismo , Adulto , Idoso , Cistos do Sistema Nervoso Central/diagnóstico por imagem , Vazamento de Líquido Cefalorraquidiano/diagnóstico por imagem , Feminino , Humanos , Hidrocefalia de Pressão Normal/diagnóstico por imagem , Injeções Espinhais , Imageamento por Ressonância Magnética , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Glândula Pineal/diagnóstico por imagem , Pseudotumor Cerebral/diagnóstico por imagem
4.
Sci Rep ; 10(1): 14974, 2020 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-32917953

RESUMO

Extra-vascular molecular clearance routes from the brain and cerebrospinal fluid (CSF) remain insufficiently characterized in humans. Animal studies consistently suggest that the cribriform plate and nasal lymphatic vessels are crucial for molecular clearance from CSF. In this study, we aimed to examine human in vivo transport of a CSF tracer from CSF to nasal mucosa. We hypothesised a CSF tracer would enrich in nasal mucosa provided that nasal lymphatic drainage has a significant role in CSF molecular clearance. Consecutive magnetic resonance imaging during 48 h after intrathecal administration of a tracer (gadobutrol) was performed in 24 patients. Despite a strong enrichment of CSF tracer in CSF spaces nearby the cribriform plate, there was no significant enrichment of CSF tracer in nasal mucosa, as measured in superior, medial and inferior turbinates, or in the nasal septum. Therefore, this in vivo study questions the importance of CSF drainage to the human nasal mucosa and emphasizes the need of further human studies.


Assuntos
Encéfalo , Líquido Cefalorraquidiano/metabolismo , Imageamento por Ressonância Magnética , Mucosa Nasal , Compostos Organometálicos/administração & dosagem , Adulto , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/diagnóstico por imagem , Mucosa Nasal/metabolismo , Estudos Prospectivos
5.
PLoS One ; 12(11): e0188896, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29190788

RESUMO

Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of "true" normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations.


Assuntos
Pressão Intracraniana/fisiologia , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Hidrocefalia de Pressão Normal/diagnóstico por imagem , Hidrocefalia de Pressão Normal/cirurgia , Masculino , Pessoa de Meia-Idade
6.
Eur J Radiol ; 95: 28-32, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28987681

RESUMO

BACKGROUND AND PURPOSE: Assessment of ventricular enlargement is subjective and based on the radiologist's experience. Linear indices, such as the Evans Index (EI), have been proposed as markers of ventricular volume with an EI≥0.3 indicating pathologic ventricular enlargement in any subject. However, normal range for EI measured on magnetic resonance imaging (MRI) scans are lacking in healthy elderly according to age and sex. We propose new age and sex specific cut-off values for ventricular enlargement in the elderly population. MATERIALS AND METHODS: 534 participants (53% women) aged 65-84 years; 226 patients with Alzheimer's disease (AD), and 308 healthy elderly controls (CTR) from the AddNeuroMed and ADNI studies were included. The cut-off for pathological ventricular enlargement was estimated from healthy elderly categorized into age groups of 5 years range and defined as EI 97,5 percentile (mean+2SD). Cut-off values were tested on patients with Alzheimer's disease and a small sample of patients with probable idiopathic normal pressure hydrocephalus (iNPH) to assess the sensitivity. RESULTS: The range of the EI in healthy elderly is wide and 29% of the CTR had an EI of 0.3 or greater. The EI increases with age in both CTR and AD, and the overall EI for women were lower than for men (p<0.001). New EI cut off values for male/female: 65-69 years 0.34/0.32, 70-74 years 0.36/0.33, 75-79 years 0.37/0.34 and 80-84 years 0.37/0.36. When applying the proposed cut-offs for EI in men and women aged 65-84, they differentiated between iNPH and CTR with a sensitivity of 80% and for different age and sex categories of AD and CTR with a sensitivity and specificity of 0-27% and 91-98%, respectively. CONCLUSION: The range of the EI measurements in healthy elderly is wide, and a cut-off value of 0.3 cannot be used to differentiate between normal and enlarged ventricles in individual cases. The proposed EI thresholds from the present study show good sensitivity for the iNPH diagnosis.


Assuntos
Doença de Alzheimer/patologia , Idoso , Idoso de 80 Anos ou mais , Ventrículos Cerebrais/patologia , Feminino , Humanos , Hidrocefalia de Pressão Normal/diagnóstico , Imageamento por Ressonância Magnética , Masculino , Tamanho do Órgão , Valores de Referência , Sensibilidade e Especificidade
7.
Neuroradiology ; 54(5): 435-43, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21647587

RESUMO

INTRODUCTION: Change detection is a crucial factor in monitoring of slowly evolving pathologies. The objective of the study was to test a semi-automatic method applied on longitudinal MRI monitoring of volume change in pituitary macroadenomas. METHODS: The proposed method is based on a visual comparison of geometrically corrected, co-registered, intensity-normalized contrast-enhanced (CE) 3D GRE T1-weighted images. Qualitative volume changes based on this applied method were compared with experts' readings of conventional pre- and post-CE 2D T1-weighted images. Magnetic resonance (MR) imaging was performed two to four times in 13 patients with a total combination of 29 time points. RESULTS: Compared to conventional 2D MR readings, a diagnosis of tumor growth (yes/no) was changed in 5 of 13 patients (38%) at 9 of the 29 combinations of time points (31%) using the 3D-based semi-automatic method. With manual tumor tracings as reference, McNemar's test showed a significant difference between the two methods. CONCLUSION: Visual comparison of geometrically corrected, intensity-normalized, and affine-aligned longitudinal 3D images may enable more accurate assessment of qualitative volumetric change in pituitary adenomas than conventional reading of 2D images.


Assuntos
Adenoma/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias Hipofisárias/patologia , Adulto , Idoso , Área Sob a Curva , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA