1.
Am J Physiol Heart Circ Physiol ; 310(10): H1371-80, 2016 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-26968545

RESUMO

To provide a model close to the human heart, and to study intrinsic cardiac function at the same time as electromechanical coupling, we developed a magnetic resonance (MR)-compatible setup of isolated working perfused pig hearts. Hearts from pigs (40 kg, n = 20) and sheep (n = 1) were blood perfused ex vivo in the working mode with and without loaded right ventricle (RV), for 80 min. Cardiac function was assessed by measuring left intraventricular pressure and left ventricular (LV) ejection fraction (LVEF), aortic and mitral valve dynamics, and native T1 mapping with MR imaging (1.5 Tesla). Potential myocardial alterations were assessed at the end of ex vivo perfusion from late-Gadolinium enhancement T1 mapping. The ex vivo cardiac function was stable across the 80 min of perfusion. Aortic flow and LV-dP/dtmin were significantly higher (P < 0.05) in hearts perfused with loaded RV, without differences for heart rate, maximal and minimal LV pressure, LV-dP/dtmax, LVEF, and kinetics of aortic and mitral valves. T1 mapping analysis showed a spatially homogeneous distribution over the LV. Simultaneous recording of hemodynamics, LVEF, and local cardiac electrophysiological signals were then successfully performed at baseline and during electrical pacing protocols without inducing alteration of MR images. Finally, (31)P nuclear MR spectroscopy (9.4 T) was also performed in two pig hearts, showing phosphocreatine-to-ATP ratio in accordance with data previously reported in vivo. We demonstrate the feasibility to perfuse isolated pig hearts in the working mode, inside an MR environment, allowing simultaneous assessment of cardiac structure, mechanics, and electrophysiology, illustrating examples of potential applications.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Metabolismo Energético , Coração/fisiologia , Hemodinâmica , Preparação de Coração Isolado/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/metabolismo , Perfusão , Potenciais de Ação , Trifosfato de Adenosina/metabolismo , Animais , Pressão Arterial , Estudos de Viabilidade , Frequência Cardíaca , Cinética , Fosfocreatina/metabolismo , Carneiro Doméstico , Volume Sistólico , Sus scrofa , Função Ventricular Esquerda , Função Ventricular Direita , Pressão Ventricular
3.
Circ Arrhythm Electrophysiol ; 6(1): 144-50, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23392586

RESUMO

BACKGROUND: Contact force (CF) is an important determinant of lesion formation for atrial endocardial radiofrequency ablation. There are minimal published data on CF and ventricular lesion formation. We studied the impact of CF on lesion formation using an ovine model both endocardially and epicardially. METHODS AND RESULTS: Twenty sheep received 160 epicardial and 160 endocardial ventricular radiofrequency applications using either a 3.5-mm irrigated-tip catheter (Thermocool, Biosense-Webster, n=160) or a 3.5 irrigated-tip catheter with CF assessment (Tacticath, Endosense, n=160), via percutaneous access. Power was delivered at 30 watts for 60 seconds, when either catheter/tissue contact was felt to be good or when CF>10 g with Tacticath. After completion of all lesions, acute dimensions were taken at pathology. Identifiable lesion formation from radiofrequency application was improved with the aid of CF information, from 78% to 98% on the endocardium (P<0.001) and from 90% to 100% on the epicardium (P=0.02). The mean total force was greater on the endocardium (39±18 g versus 21±14 g for the epicardium; P<0.001) mainly because of axial force. Despite the force-time integral being greater endocardially, epicardial lesions were larger (231±182 mm(3) versus 209±131 mm(3); P=0.02) probably because of the absence of the heat sink effect of the circulating blood and covered a greater area (41±27 mm(2) versus 29±17 mm(2); P=0.03) because of catheter orientation. CONCLUSIONS: In the absence of CF feedback, 22% of endocardial radiofrequency applications that are thought to have good contact did not result in lesion formation. Epicardial ablation is associated with larger lesions.


Assuntos
Ablação por Cateter/métodos , Endocárdio/cirurgia , Ventrículos do Coração/cirurgia , Pericárdio/cirurgia , Animais , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Endocárdio/patologia , Desenho de Equipamento , Ventrículos do Coração/patologia , Pericárdio/patologia , Ovinos , Irrigação Terapêutica