Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ann Pharm Fr ; 82(1): 96-109, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37625529

RESUMO

OBJECTIVE: A simple, highly specific, accurate and fast method by smartphone-based digital imaging was developed for estimating lidocaine hydrochloride in pharmaceutical formulations. MATERIAL AND METHODS: To obtain the images, a Galaxy A03 Core smartphone and an image acquisition device developed in the laboratory were used to control the incident factors in reproducibility of the measurements. The processing of the images was carried out with the Color Grab application. Finally, the absorbance values were calculated using the RGB intensity values of blank, standard, and sample solutions. The proposed method was compared with spectroscopic and chromatographic methods. RESULTS: The reaction between copper and lidocaine hydrochloride was characterized, showing better results in an equimolar ratio and maintaining the pH of the solution above 11.5. The use of the device for the capture of digital images allowed to control those sensitive parameters for reproducibility so that the analytical measurements showed adequate precision and accuracy. Validation of the main parameters of the method showed compliance with acceptance criteria. The application of the method for the analysis of injectable samples achieved reliable results, which were statistically similar to other reference instrumental methods. CONCLUSION: The proposed method presented figures of merit in relation to linearity, precision, selectivity, accuracy, and robustness; it was carried out by designing and manufacturing a device for capturing digital images on a smartphone, which were analyzed to obtain RGB intensity values. These data are finally used to calculate absorbance values of solutions. All these elements provide this work with innovative characteristics in the field of analysis for control of pharmaceutical formulations.


Assuntos
Lidocaína , Smartphone , Análise Custo-Benefício , Composição de Medicamentos , Lidocaína/análise , Lidocaína/química , Reprodutibilidade dos Testes
2.
Cell Syst ; 11(2): 186-195.e9, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32710834

RESUMO

Cancer is driven by genomic alterations, but the processes causing this disease are largely performed by proteins. However, proteins are harder and more expensive to measure than genes and transcripts. To catalyze developments of methods to infer protein levels from other omics measurements, we leveraged crowdsourcing via the NCI-CPTAC DREAM proteogenomic challenge. We asked for methods to predict protein and phosphorylation levels from genomic and transcriptomic data in cancer patients. The best performance was achieved by an ensemble of models, including as predictors transcript level of the corresponding genes, interaction between genes, conservation across tumor types, and phosphosite proximity for phosphorylation prediction. Proteins from metabolic pathways and complexes were the best and worst predicted, respectively. The performance of even the best-performing model was modest, suggesting that many proteins are strongly regulated through translational control and degradation. Our results set a reference for the limitations of computational inference in proteogenomics. A record of this paper's transparent peer review process is included in the Supplemental Information.


Assuntos
Crowdsourcing/métodos , Genômica/métodos , Aprendizado de Máquina/normas , Neoplasias/genética , Fosfoproteínas/metabolismo , Proteínas/genética , Proteômica/métodos , Transcriptoma/genética , Feminino , Humanos , Masculino
3.
J Proteome Res ; 15(3): 691-706, 2016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26653538

RESUMO

The NCI Clinical Proteomic Tumor Analysis Consortium (CPTAC) employed a pair of reference xenograft proteomes for initial platform validation and ongoing quality control of its data collection for The Cancer Genome Atlas (TCGA) tumors. These two xenografts, representing basal and luminal-B human breast cancer, were fractionated and analyzed on six mass spectrometers in a total of 46 replicates divided between iTRAQ and label-free technologies, spanning a total of 1095 LC-MS/MS experiments. These data represent a unique opportunity to evaluate the stability of proteomic differentiation by mass spectrometry over many months of time for individual instruments or across instruments running dissimilar workflows. We evaluated iTRAQ reporter ions, label-free spectral counts, and label-free extracted ion chromatograms as strategies for data interpretation (source code is available from http://homepages.uc.edu/~wang2x7/Research.htm ). From these assessments, we found that differential genes from a single replicate were confirmed by other replicates on the same instrument from 61 to 93% of the time. When comparing across different instruments and quantitative technologies, using multiple replicates, differential genes were reproduced by other data sets from 67 to 99% of the time. Projecting gene differences to biological pathways and networks increased the degree of similarity. These overlaps send an encouraging message about the maturity of technologies for proteomic differentiation.


Assuntos
Xenoenxertos/química , Proteômica/métodos , Proteômica/normas , Neoplasias da Mama/química , Neoplasias da Mama/metabolismo , Cromatografia Líquida , Interpretação Estatística de Dados , Feminino , Perfilação da Expressão Gênica/métodos , Humanos , Redes e Vias Metabólicas , Variações Dependentes do Observador , Proteoma , Proteômica/instrumentação , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/normas
4.
Mol Cell Proteomics ; 12(9): 2623-39, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23689285

RESUMO

Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.


Assuntos
Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Sequência de Aminoácidos , Animais , Bovinos , Limite de Detecção , Dados de Sequência Molecular , Peptídeos/química , Peptídeos/metabolismo , Padrões de Referência , Software , Fatores de Tempo
5.
Clin Chem ; 56(2): 165-71, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20007858

RESUMO

As a part of ongoing efforts of the NCI-FDA Interagency Oncology Task Force subcommittee on molecular diagnostics, members of the Clinical Proteomic Technology Assessment for Cancer program of the National Cancer Institute have submitted 2 protein-based multiplex assay descriptions to the Office of In Vitro Diagnostic Device Evaluation and Safety, US Food and Drug Administration. The objective was to evaluate the analytical measurement criteria and studies needed to validate protein-based multiplex assays. Each submission described a different protein-based platform: a multiplex immunoaffinity mass spectrometry platform for protein quantification, and an immunological array platform quantifying glycoprotein isoforms. Submissions provided a mutually beneficial way for members of the proteomics and regulatory communities to identify the analytical issues that the field should address when developing protein-based multiplex clinical assays.


Assuntos
Testes Diagnósticos de Rotina/normas , Proteômica/normas , United States Food and Drug Administration/normas , Testes Diagnósticos de Rotina/métodos , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Proteômica/métodos , Estados Unidos
6.
J Proteome Res ; 9(2): 761-76, 2010 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-19921851

RESUMO

The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35-60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind repeatability of technical replicates on a single instrument by several percent. These findings reinforce the importance of evaluating repeatability as a fundamental characteristic of analytical technologies.


Assuntos
Cromatografia Líquida/métodos , Proteoma , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
7.
Nat Biotechnol ; 27(7): 633-41, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19561596

RESUMO

Verification of candidate biomarkers relies upon specific, quantitative assays optimized for selective detection of target proteins, and is increasingly viewed as a critical step in the discovery pipeline that bridges unbiased biomarker discovery to preclinical validation. Although individual laboratories have demonstrated that multiple reaction monitoring (MRM) coupled with isotope dilution mass spectrometry can quantify candidate protein biomarkers in plasma, reproducibility and transferability of these assays between laboratories have not been demonstrated. We describe a multilaboratory study to assess reproducibility, recovery, linear dynamic range and limits of detection and quantification of multiplexed, MRM-based assays, conducted by NCI-CPTAC. Using common materials and standardized protocols, we demonstrate that these assays can be highly reproducible within and across laboratories and instrument platforms, and are sensitive to low mug/ml protein concentrations in unfractionated plasma. We provide data and benchmarks against which individual laboratories can compare their performance and evaluate new technologies for biomarker verification in plasma.


Assuntos
Proteínas Sanguíneas/análise , Espectrometria de Massas/métodos , Biomarcadores/sangue , Análise Química do Sangue/métodos , Humanos , Modelos Lineares , Espectrometria de Massas/normas , Proteoma/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Avaliação da Tecnologia Biomédica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA