RESUMO
OBJECTIVE: Given recent data on published diagnostic accuracies, this study sought to determine the most cost-effective diagnostic strategy for detection of significant coronary artery disease (CAD) in stable angina patients using invasive coronary angiography (ICA) and fractional flow reserve (FFR) as the reference standard. METHODS: A probabilistic decision-analytical model was developed which modelled a cohort of patients with stable angina. We investigated 17 diagnostic strategies between standalone and combination of different imaging tests to establish a correct diagnosis of CAD, using no testing as the baseline reference. These tests included CT coronary angiography (CTCA), stress echocardiography, CT-based FFR, single-photon emission computed tomography (SPECT), cardiovascular magnetic resonance (CMR), positron emission tomography, ICA, and ICA with FFR. Incremental cost-effectiveness ratios were calculated as the additional cost per correct diagnosis. RESULTS: SPECT followed by CTCA and ICA-FFR is the most cost-effective strategy between a cost-effectiveness threshold (CET) value of £1000-£3000 per correct diagnosis. CMR followed by CTCA and ICA-FFR is cost-effective within a CET range of £3000-£17 000 per correct diagnosis. CMR and ICA-FFR is cost-effective within a CET range of £17 000-£24 000. ICA-FFR as first line is the most-cost effective if the CET value exceeds the £24 000 per correct diagnosis. Sensitivity analysis showed that direct ICA-FFR may be cost-effective in patients with a high pre-test probability of CAD. CONCLUSION: First-line testing with functional imaging is cost-effective at low to intermediate value of correct diagnosis in patients with low to intermediate risk of CAD. ICA is not cost effective although ICA-FFR may be at higher CET.
Assuntos
Angina Estável , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Angina Estável/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Análise Custo-Benefício , HumanosRESUMO
BACKGROUND AND AIMS: Infection is a serious and expensive complication of Cardiac Implantable Electronic Device (CIED) procedures. A retrospective based cost analysis was performed to estimate Trust level savings of using the TYRX antibacterial envelope as a primary prevention measure against infection in a tertiary referral centre in South London, UK. METHODS: A retrospective cohort of heart failure patients with reduced ejection fraction undergoing Implantable Cardioverter Defibrillator (ICD) or Cardiac Resynchronization Therapy (CRT) procedures were evaluated. Decision-analytic modelling was performed to determine economic savings of using the envelope during CIED procedure vs CIED procedure alone. RESULTS: Over a 12 month follow-up period following CIED procedure, the observed infection rate was 3.14% (n = 5/159). The average cost of a CIED infection inpatient admission was £41,820 and, further to economic analysis, the additional costs attributable to infection was calculated at £62,213.94. A cost saving of £624 per patient by using TYRX during CIED procedure as a primary preventative measure against infection was estimated. CONCLUSIONS: TYRX would be a cost-saving treatment option amongst heart failure patients undergoing ICD and CRT device procedures based on analysis in the local geographical area of South London. If upscaled to the UK population, we estimate potential cost savings for the National Health Service (NHS).