Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 17356, 2019 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-31757980

RESUMO

Aim of this study was to establish a simple and highly reproducible physiological circulation model to investigate endovascular device performance. The developed circulation model included a pneumatically driven pulsatile pump to generate a flow rate of 2.7 L/min at 70 beats per minute. Sections from the superficial femoral arteries were used in order to simulate device/tissue interaction and a filter was integrated to analyze periinterventional thromboembolism of white, red and mixed thrombi. The working fluid (3 L) was a crystalloid solution constantly tempered at 36.5 °C. To evaluate the model, aspiration thrombectomy, stent-implantation and thrombectomy with the Fogarty catheter were performed. Usability of the model was measured by the System Usability Scale (SUS) - Score. Histological specimens were prepared and analyzed postinterventional to quantify tissue/device interaction. Moreover, micro- and macroembolism were evaluated for each thrombus entity and each device. Results were tested for normality using the D'Agostino-Pearson test. Statistical comparisons of two groups were performed using the Student's t-test. All devices were able to remove the occlusions after a maximum of 2 attempts. First-pass-recanalization was not fully achieved for aspiration thrombectomy of mixed thrombi (90.6%), aspiration thrombectomy of red thrombi (84.4%) and stent-implantation in occlusions of red thrombi (92.2%). Most micro- and macroembolism were observed using the Fogarty catheter and after stent-implantation in occlusions of white thrombi. Histological examinations revealed a significant reduction of the vascular layers suggesting vascular damage after use of the Fogarty catheter (327.3 ± 3.5 µm vs. 440.6 ± 3.9 µm; p = 0.026). Analysis of SUS rendered a mean SUS-Score of 80.4 which corresponds to an excellent user acceptability of the model. In conclusion, we describe a stable, easy to handle and reproducible physiological circulation model for the simulation of endovascular thrombectomy including device performance and thromboembolism.


Assuntos
Circulação Sanguínea/fisiologia , Cateterismo , Procedimentos Endovasculares , Modelos Cardiovasculares , Trombose/patologia , Trombose/cirurgia , Cateterismo/efeitos adversos , Cateterismo/instrumentação , Cateterismo/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Estudos de Viabilidade , Artéria Femoral , Humanos , Técnicas In Vitro , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/patologia , Stents , Trombectomia/efeitos adversos , Trombectomia/instrumentação , Trombectomia/métodos , Tromboembolia/etiologia , Tromboembolia/patologia , Tromboembolia/fisiopatologia , Tromboembolia/cirurgia , Trombose/etiologia , Trombose/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA