Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Regul Toxicol Pharmacol ; 125: 105004, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34256083

RESUMO

In 2017, the European Union (EU) Committee for Risk Assessment (RAC) recommended the classification of metallic cobalt (Co) as Category 1B with respect to its carcinogenic and reproductive hazard potential and Category 2 for mutagenicity but did not evaluate the relevance of these classifications for patients exposed to Co-containing alloys (CoCA) used in medical devices. CoCA are inherently different materials from Co metal from a toxicological perspective and thus require a separate assessment. CoCA are biocompatible materials with a unique combination of properties including strength, durability, and a long history of safe use that make them uniquely suited for use in a wide-range of medical devices. Assessments were performed on relevant preclinical and clinical carcinogenicity and reproductive toxicity data for Co and CoCA to meet the requirements under the EU Medical Device Regulation triggered by the ECHA re-classification (adopted in October 2019 under the 14th Adaptation to Technical Progress to CLP) and to address their relevance to patient safety. The objective of this review is to present an integrated overview of these assessments, a benefit-risk assessment and an examination of potential alternative materials. The data support the conclusion that the exposure to CoCA in medical devices via clinically relevant routes does not represent a hazard for carcinogenicity or reproductive toxicity. Additionally, the risk for the adverse effects that are known to occur with elevated Co concentrations (e.g., cardiomyopathy) are very low for CoCA implant devices (infrequent reports often reflecting a unique catastrophic failure event out of millions of patients) and negligible for CoCA non-implant devices (not measurable/no case reports). In conclusion, the favorable benefit-risk profile also in relation to possible alternatives presented herein strongly support continued use of CoCA in medical devices.


Assuntos
Ligas/química , Cobalto/análise , Equipamentos e Provisões/normas , Doenças Genitais/epidemiologia , Neoplasias/epidemiologia , Carcinogênese , União Europeia , Humanos , Próteses e Implantes/normas , Medição de Risco , Aço/análise
2.
Regul Toxicol Pharmacol ; 122: 104910, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33662479

RESUMO

Cobalt (Co) alloys have been used for over seven decades in a wide range of medical devices, including, but not limited to, hip and knee implants, surgical tools, and vascular stents, due to their favorable biocompatibility, durability, and mechanical properties. A recent regulatory hazard classification review by the European Chemicals Agency (ECHA) resulted in the classification of metallic Co as a Class 1B Carcinogen (presumed to have carcinogenic potential for humans), primarily based on inhalation rodent carcinogenicity studies with pure metallic Co. The ECHA review did not specifically consider the carcinogenicity hazard potential of forms or routes of Co that are relevant for medical devices. The purpose of this review is to present a comprehensive assessment of the available in vivo preclinical data on the carcinogenic hazard potential of exposure to Co-containing alloys (CoCA) in medical devices by relevant routes. In vivo data were reviewed from 33 preclinical studies that examined the impact of Co exposure on local and systemic tumor incidence in rats, mice, guinea pigs, and hamsters. Across these studies, there was no significant increase of local or systemic tumors in studies relevant for medical devices. Taken together, the relevant in vivo data led to the conclusion that CoCA in medical devices are not a carcinogenic hazard in available in vivo models. While specific patient and implant factors cannot be fully replicated using in vivo models, the available in vivo preclinical data support that CoCA in medical devices are unlikely a carcinogenic hazard to patients.


Assuntos
Ligas/análise , Cobalto/análise , Equipamentos e Provisões , Ligas/administração & dosagem , Animais , Carcinogênese , Cobalto/administração & dosagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA