Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38189979

RESUMO

OBJECTIVES: To investigate intra-patient variability of iodine concentration (IC) between three different dual-energy CT (DECT) platforms and to test different normalization approaches. METHODS: Forty-four patients who underwent portal venous phase abdominal DECT on a dual-source (dsDECT), a rapid kVp switching (rsDECT), and a dual-layer detector platform (dlDECT) during cancer follow-up were retrospectively included. IC in the liver, pancreas, and kidneys and different normalized ICs (NICPV:portal vein; NICAA:abdominal aorta; NICALL:overall iodine load) were compared between the three DECT scanners for each patient. A longitudinal mixed effects analysis was conducted to elucidate the effect of the scanner type, scan order, inter-scan time, and contrast media amount on normalized iodine concentration. RESULTS: Variability of IC was highest in the liver (dsDECT vs. dlDECT 28.96 (14.28-46.87) %, dsDECT vs. rsDECT 29.08 (16.59-62.55) %, rsDECT vs. dlDECT 22.85 (7.52-33.49) %), and lowest in the kidneys (dsDECT vs. dlDECT 15.76 (7.03-26.1) %, dsDECT vs. rsDECT 15.67 (8.86-25.56) %, rsDECT vs. dlDECT 10.92 (4.92-22.79) %). NICALL yielded the best reduction of IC variability throughout all tissues and inter-scanner comparisons, yet did not reduce the variability between dsDECT vs. dlDECT and rsDECT, respectively, in the liver. The scanner type remained a significant determinant for NICALL in the pancreas and the liver (F-values, 12.26 and 23.78; both, p < 0.0001). CONCLUSIONS: We found tissue-specific intra-patient variability of IC across different DECT scanner types. Normalization mitigated variability by reducing physiological fluctuations in iodine distribution. After normalization, the scanner type still had a significant effect on iodine variability in the pancreas and liver. CLINICAL RELEVANCE STATEMENT: Differences in iodine quantification between dual-energy CT scanners can partly be mitigated by normalization, yet remain relevant for specific tissues and inter-scanner comparisons, which should be taken into account at clinical routine imaging. KEY POINTS: • Iodine concentration showed the least variability between scanner types in the kidneys (range 10.92-15.76%) and highest variability in the liver (range 22.85-29.08%). • Normalizing tissue-specific iodine concentrations against the overall iodine load yielded the greatest reduction of variability between scanner types for 2/3 inter-scanner comparisons in the liver and for all (3/3) inter-scanner comparisons in the kidneys and pancreas, respectively. • However, even after normalization, the dual-energy CT scanner type was found to be the factor significantly influencing variability of iodine concentration in the liver and pancreas.

3.
Radiology ; 296(2): E26-E31, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32267209

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic initially manifested in the United States in the greater Seattle area and has rapidly progressed across the nation in the past 2 months, with the United States having the highest number of cases in the world. Radiology departments play a critical role in policy and guideline development both for the department and for the institutions, specifically in planning diagnostic screening, triage, and management of patients. In addition, radiology workflows, volumes, and access must be optimized in preparation for the expected surges in the number of patients with COVID-19. In this article, the authors discuss the processes that have been implemented at the University of Washington in managing the COVID-19 pandemic as well in preparing for patient surges, which may provide important guidance for other radiology departments who are in the early stages of preparation and management.


Assuntos
COVID-19 , Política de Saúde , COVID-19/diagnóstico , COVID-19/terapia , Planejamento em Desastres , Hospitalização , Hospitais Universitários , Humanos , Pandemias , Guias de Prática Clínica como Assunto , Serviço Hospitalar de Radiologia/legislação & jurisprudência , Serviço Hospitalar de Radiologia/organização & administração , Serviço Hospitalar de Radiologia/estatística & dados numéricos , SARS-CoV-2 , Washington
4.
Radiographics ; 39(3): 744-758, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30901285

RESUMO

Technical advances in MRI have improved image quality and have led to expanding clinical indications for its use. However, long examination and interpretation times, as well as higher costs, still represent barriers to use of MRI. Abbreviated MRI protocols have emerged as an alternative to standard MRI protocols. These abbreviated MRI protocols seek to reduce longer MRI protocols by eliminating unnecessary or redundant sequences that negatively affect cost, MRI table time, patient comfort, image quality, and image interpretation time. However, the diagnostic information is generally not compromised. Abbreviated MRI protocols have already been used successfully for hepatocellular carcinoma screening, for prostate cancer detection, and for screening for nonalcoholic fatty liver disease as well as monitoring patients with this disease. It has been reported that image acquisition time and costs can be considerably reduced with abbreviated MRI protocols, compared with standard MRI protocols, while maintaining a similar sensitivity and accuracy. Nevertheless, multiple applications still need to be explored in the abdomen and pelvis (eg, surveillance of metastases to the liver; follow-up of cystic pancreatic lesions, adrenal incidentalomas, and small renal masses; evaluation of ovarian cysts in postmenopausal women; staging of cervical and uterine corpus neoplasms; evaluation of müllerian duct anomalies). This article describes some successful applications of abbreviated MRI protocols, demonstrates how they can help in improving the MRI workflow, and explores potential future directions. ©RSNA, 2019.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/secundário , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos Clínicos , Neoplasias Colorretais , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/tendências , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem , Assistência Centrada no Paciente , Neoplasias da Próstata/diagnóstico por imagem
5.
Abdom Radiol (NY) ; 44(3): 1019-1026, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30415309

RESUMO

PURPOSE: The purpose of this study was to investigate the image quality (IQ) considerations of rapid kVp switching dual-energy CT (rsDECT) in the assessment of urolithiasis in patients with large body habitus and to evaluate whether it allows stone characterization. MATERIALS AND METHODS: In this IRB-approved, HIPAA compliant retrospective study, 93 consecutive patients (M/F = 72/21, mean age 56.9 years, range 23-83 years) with large body habitus (> 90 kg/198 lbs) who underwent dual-energy (DE) stone protocol CT on a rapid kVp switching DECT scanner between January 2013 and December 2016 were included. Scan acquisition protocol included an initial unenhanced single-energy CT (SECT) scan of KUB followed by targeted DECT in the region of stones. Two readers evaluated both CT data sets (axial 5 mm 120 kVp/140 kVp QC/70 keV monoenergetic, material density water/iodine images and coronal/sagittal 3 mm images) for the assessment of image quality (Scores: 1-4) and characterization of stone composition (reference standard: crystallography). RESULTS: One hundred and five CT examinations were performed in 93 patients (mean body weight 105.12 ± 13.53 kg, range 91-154 kg), and a total of 321 urinary tract calculi (mean size-4.8 ± 3.2 mm, range 1.2-22 mm) were detected. Both SECT and targeted monoenergetic images were of acceptable image quality (mean IQ: 3.77 and 3.83, kappa 0.79 and 0.87 respectively). Material density water and iodine images had lower IQ scores (mean IQ: 2.97 and 3.09 respectively) with image quality deterioration due to severe photon starvation/streak artifacts in 20% (21/105) and 17% (18/105) scans, respectively. Characterization of stone composition into uric acid/non-uric acid stones was achieved in 93.14% (299/321) of calculi (mean size: 4.99 ± 3.3 mm, range 1.2-22 mm), while 7% (22/321) stones could not be characterized (mean size 3.03 ± 1.16 mm, range 1.6-6.4 mm) (p < 0.001). Most common reason for non-characterization was image quality deterioration of the material density iodine images due to severe photon starvation artifacts. On multivariate regression, stone size and patient weight were predictors of stone composition determination on DECT (p < 0.05). The transverse diameter had a weak negative correlation with stone composition determination, but it was not statistically significant. Stone characterization into uric acid vs. non-uric acid stones was accurate in 95% (n = 38/40) of stones in comparison with crystallography. CONCLUSION: In patients with large body habitus, rsDECT allowed characterization of most calculi (93%) despite image quality deterioration due to photon starvation/streak artifacts in up to 20% of material density images. Stone size and patient weight were predictors of stone composition determination on DECT, and small calculi in very large patients may not be characterized.


Assuntos
Tamanho Corporal , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
6.
Abdom Radiol (NY) ; 43(2): 497-504, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29138890

RESUMO

PURPOSE: The purpose of this study is to evaluate the performance of material-specific iodine (MS-I) images generated by rapid kV-switching single-source dual-energy computed tomography (rsDECT) for distinguishing post-operative changes from local tumor recurrence in patients on follow-up for pancreatic adenocarcinoma after surgical resection. METHODS: In this IRB-approved HIPPA-compliant study, retrospective review of 51 patients who underwent surgical resection of pancreatic adenocarcinoma was conducted and were followed up using contrast-enhanced rsDECT (Discovery CT 750HD, GE Healthcare, Milwaukee, WI). Independent qualitative assessment for presence of local tumor recurrence was performed by two radiologists who evaluated 65 keV (single-energy CT-equivalent interpretation) and 65 keV with MS-I (rsDECT interpretation) in separate sessions. Quantitative analysis of Hounsfield unit (HU, on 65 keV) and normalized iodine concentration (NIC on MS-I images; iodine concentration ratio in post-operative tissue to aorta) was measured. Follow-up imaging, temporal change of CEA and CA 19-9 or biopsy served as reference standard for presence and absence of local recurrence. Sensitivity and specificity of readers and quantitative parameters was calculated and receiver operating characteristic curves and Fisher's exact test were generated. A p value < 0.05 was considered statistically significant. RESULTS: A total of 51 patients (27 females, 24 males) with mean age of 64 years built the final cohort. Local recurrence was absent in 23 (Group A) and present in 28 (Group B) patients. The follow-up imaging was performed within 7 months of rsDECT. For both readers, the addition of MS-I increased the specificity for tissue characterization and improved reader confidence as compared to 65 keV (specificity: 80% and 56%, respectively) images alone. Quantitative analysis revealed a significantly lower NIC (0.28 vs. 0.35; p < 0.05) for non-recurrent tissue. However, HU was not significantly different for non-recurrent and recurrent tissue (0.63 vs. 0.70; p > 0.05). CONCLUSION: In inherently complex cases of post-operative pancreatic adenocarcinoma, MS-I images from rsDECT can be a useful adjunct to conventional scans in characterizing loco-regional soft tissue.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Resultado do Tratamento
7.
AJR Am J Roentgenol ; 208(1): 18-31, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27786547

RESUMO

OBJECTIVE: The purpose of this article is to examine the role of different imaging biomarkers, focusing in particular on the use of updated CT and PET response criteria for the assessment of oncologic treatment effectiveness in patients with lymphoma but also discussing other potential functional imaging methods and their limitations. CONCLUSION: Lymph nodes are commonly involved by metastatic solid tumors as well as by lymphoma. Evolving changes in cancer therapy for lymphoma and metastases have led to improved clinical outcomes. Imaging is a recognized surrogate endpoint that uses established criteria based on changes in tumor bulk to monitor the effects of treatment. With the introduction of targeted therapies and novel antiangiogenic drugs, the oncologic expectations from imaging assessment are changing to move beyond simple morphologic methods. Molecular and functional imaging methods (e.g., PET, perfusion, DWI, and dual-energy CT) are therefore being investigated as imaging biomarkers of response and prognosis. The role of these advanced imaging biomarkers extends beyond measuring tumor burden and therefore might offer insight into early predictors of therapeutic response. Despite the potential benefits of these exciting imaging biomarkers, several challenges currently exist.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Linfoma/diagnóstico por imagem , Linfoma/terapia , Avaliação de Resultados em Cuidados de Saúde/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagem Molecular/métodos , Resultado do Tratamento
8.
Indian J Radiol Imaging ; 25(2): 121-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25969635

RESUMO

Morphologic methods such as the Response Evaluation Criteria in Solid Tumors (RECIST) are considered as the gold standard for response assessment in the management of cancer. However, with the increasing clinical use of antineoplastic cytostatic agents and locoregional interventional therapies in hepatocellular carcinoma (HCC), conventional morphologic methods are confronting limitations in response assessment. Thus, there is an increasing interest in new imaging methods for response assessment, which can evaluate tumor biology such as vascular physiology, fibrosis, necrosis, and metabolism. In this review, we discuss various novel imaging methods for response assessment and compare them with the conventional ones in HCC.

9.
Abdom Imaging ; 40(6): 1705-12, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25526682

RESUMO

PURPOSE: To evaluate the role of computed tomography (CT) texture analysis in assessing response of soft tissue sarcoma (STS) treated with neoadjuvant bevacizumab (BVZ) plus radiotherapy in comparison to tumor size, density, and perfusion. METHODS: In the phase II clinical trial, 20 patients with STSs received BVZ alone for 2 weeks followed by BVZ plus radiotherapy for 6 weeks prior to surgery. All patients received CT perfusion at baseline, 2 and 8 weeks after the therapy, and tumor blood flow (BF) was measured. In contrast enhanced CT image at the arterial peak enhancement time, mean of positive pixels (MPP) was measured as a texture parameter using texture analysis software, and tumor size and density were also measured. The percent changes of these parameters were compared with pathological response on surgical specimen. RESULTS: After 2 weeks of the therapy, MPP and BF decreased by 10.42% and 20.08%, while changes of tumor size and density were not obvious. After 8 weeks, MPP, BF, and density decreased by 29.2% (p = 0.03), 53.2% (p = 0.001), and 30.41% (p = 0.005), respectively, without a significant change in size. The percent change of MPP after 8 weeks had a significant correlation with tumor necrosis in surgical specimen (r = -0.801, p < 0.001), whereas those of size, density, and BF did not. The receiver-operating characteristic analysis demonstrated that the percent change of MPP < -35.36% was an optimal cut-off value to differentiate pathological responders. CONCLUSION: The change of MPP is the best biomarker for the treatment response in STS.


Assuntos
Tecido Conjuntivo/irrigação sanguínea , Tecido Conjuntivo/diagnóstico por imagem , Terapia Neoadjuvante , Sarcoma/diagnóstico por imagem , Sarcoma/terapia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Inibidores da Angiogênese/uso terapêutico , Bevacizumab/uso terapêutico , Tecido Conjuntivo/patologia , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica , Curva ROC , Intensificação de Imagem Radiográfica , Sarcoma/patologia
10.
J Am Coll Radiol ; 9(8): 578-82, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22863467

RESUMO

PURPOSE: The purpose of this study was to compare enhancement quality, performance efficiency, technologists' satisfaction, and operation costs between 2 different power injectors (PIs) in an outpatient setting. METHODS: In this prospective study, 275 consecutive outpatients (135 men, 140 women) scheduled for contrast-enhanced CT (CECT) were randomized and scanned using either of 2 multidetector CT scanners (16 adjacently placed detectors) fitted with a dual-syringe contrast injector or a syringeless contrast injector. The corresponding CECT studies were subjectively reviewed by 2 radiologists in consensus to rate the quality of contrast enhancement in each study. The equipment preparation time (contrast media [CM], saline loading), releasing time (unloading of saline and CM), and CM wastage incurred for each PI were recorded by one operator. Technologists' satisfaction with the use of the PIs was rated on a 10-point scale. Statistical analyses were performed using Student's t tests. RESULTS: A total of 140 patients were examined using the dual-syringe system, and 135 with the syringeless system, and CECT examination quality was comparable for both PI systems (P > .05). Equipment preparation time and releasing time per examination for dual-syringe and syringeless PIs were 139 ± 39 and 32 ± 14 seconds and 48 ± 31 and 8 ± 3 seconds, respectively (P < .001). On average, 11 mL CM wastage per examination was observed with the dual-syringe PI and 0 mL with the syringeless PI (P < .001). Technologists had higher satisfaction with the syringeless PI than the dual-syringe system (9.3 vs 6.3, P < .01). Because of improved efficiency, 2.6 additional patients per day were examined in the room using the syringeless PI. CONCLUSION: Given comparable CECT examination quality, the syringeless PI was more user-friendly and improved outpatient CT workflow and CT throughput while allowing 11-mL CM saving per examination compared with the dual-syringe injector.


Assuntos
Meios de Contraste/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Pacientes Ambulatoriais/estatística & dados numéricos , Seringas/economia , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Fluxo de Trabalho , Adolescente , Adulto , Idoso , Boston/epidemiologia , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
J Comput Assist Tomogr ; 36(4): 381-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22805664

RESUMO

PURPOSE: To evaluate the impact of subtraction CT on reader confidence and diagnostic accuracy when characterizing renal masses. MATERIALS AND METHODS: In this institutional review board-approved retrospective study, 159 patients (85 men and 74 women; mean age, 62.6 years; range, 22-88 years) underwent routine unenhanced and contrast-enhanced multidetector computed tomography (MDCT) for renal lesion characterization. Subtraction images were subsequently generated on scanner console. Two readers independently reviewed the MDCT images to characterize presence of enhancement using a 6-point scale during 3 blinded review sessions of (1) only subtraction, (2) routine, and (3) combined subtraction and routine images. The standard of reference consisted of either histopathology or follow-up imaging and clinical data. RESULTS: Of the 240 lesions evaluated, 60 lesions (mean, 3.2 cm; range, 1-7.5 cm) were enhancing and 180 lesions (mean, 2.7 cm; range, 0.5-12 cm) were nonenhancing. For determination of lesion enhancement, a combined evaluation of routine MDCT and subtraction images improved reader confidence in 60% to 63% of lesions (P < 0.001). The combined evaluation also provided the highest sensitivity (97%), specificity (99%), and accuracy (98.9%). CONCLUSION: When used in combination with routine image interpretation, subtraction CT improves reader confidence and diagnostic accuracy in identifying enhancement in renal lesions.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Iopamidol , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Software , Técnica de Subtração
12.
Ann Surg ; 254(6): 977-83, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22041510

RESUMO

OBJECTIVE: Evaluate the value of cytology relative to imaging features in risk assessment for malignancy as defined in the Sendai Guidelines. BACKGROUND: The Sendai Guidelines list symptoms, cyst size >30 mm, dilated main pancreatic duct (MPD) >6 mm, mural nodule (MN) and "positive" cytology as high risk stigmata for malignancy warranting surgical triage. METHODS: We reviewed clinical, radiological and cytological data of 112 patients with histologically confirmed mucinous cysts of the pancreas evaluated in a single tertiary medical center. Cytology slides were blindly re-reviewed and epithelial cells grouped as either benign or high-grade atypia (HGA) [≥high-grade dysplasia]. Histologically, neoplasms were grouped as benign (low-grade and moderate dysplasia) and malignant (in situ and invasive carcinoma). Performance characteristics of cytology relative to other risk factors were evaluated. RESULTS: Dilated MPD, MN, and HGA were independent predictors of malignancy (p < 0.0001), but not symptoms (p = 0.29) or cyst size >30 mm (p = 0.51). HGA was the most sensitive predictor of malignancy in all cysts (72%) and in small (≤30 mm) branch-duct intraductal papillary mucinous neoplasm (BD IPMN; 67%), whereas also being specific (85 and 88%, respectively). MN and dilated MPD were highly specific (>90%), but insensitive (39%-44%). Cytology detected 30% more cancers in small cysts than dilated MPD or MN and half of the cancers without either of these high-risk imaging features. CONCLUSIONS: Cytology adds value to the radiological assessment of predicting malignancy in mucinous cysts, particularly in small BD IPMN.


Assuntos
Adenocarcinoma Mucinoso/patologia , Carcinoma Ductal Pancreático/patologia , Cistadenocarcinoma Mucinoso/patologia , Cisto Pancreático/patologia , Neoplasias Pancreáticas/patologia , Idoso , Biópsia por Agulha Fina , Carcinoma in Situ/patologia , Transformação Celular Neoplásica/patologia , Estudos de Coortes , Diagnóstico Diferencial , Endossonografia , Feminino , Fidelidade a Diretrizes , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Ductos Pancreáticos/patologia , Medição de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção
13.
Int J Surg Oncol ; 2011: 846512, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22312527

RESUMO

Colorectal cancer is the third most commonly diagnosed cancer, accounting for 53,219 deaths in 2007 and an estimated 146,970 new cases in the USA during 2009. The combination of FDG PET and CT has proven to be of great benefit for the assessment of colorectal cancer. This is most evident in the detection of occult metastases, particularly intra- or extrahepatic sites of disease, that would preclude a curative procedure or in the detection of local recurrence. FDG PET is generally not used for the diagnosis of colorectal cancer although there are circumstances where PET-CT may make the initial diagnosis, particularly with its more widespread use. In addition, precancerous adenomatous polyps can also be detected incidentally on whole-body images performed for other indications; sensitivity increases with increasing polyp size. False-negative FDG PET findings have been reported with mucinous adenocarcinoma, and false-positive findings have been reported due to inflammatory conditions such as diverticulitis, colitis, and postoperative scarring. Therefore, detailed evaluation of the CT component of a PET/CT exam, including assessment of the entire colon, is essential.

14.
Gastrointest Endosc ; 71(6): 1018-24, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20185125

RESUMO

BACKGROUND: Gastric leak testing after natural orifice transluminal endoscopic surgery (NOTES) gastrotomy closure may help reduce the risk of leaks after transgastric procedures. OBJECTIVE: To develop a novel endoscopy-based system to determine the presence of a leak after NOTES gastrotomy and to compare this system prospectively with radiographic leak testing. DESIGN: Prospective, randomized, controlled trial. SETTING: Academic Medical Center laboratory. SUBJECTS: Fifty swine. INTERVENTION: During the pretrial phase, an endoscopic system for the measurement of intragastric pressure was developed. In the trial phase, swine with a NOTES gastrotomy were randomized to endoscopic versus radiographic leak testing. If a leak was demonstrated, the gastrotomy was reclosed by using a second-generation prototype T-anchor system. The primary outcome was leak detection after gastrotomy closure. The secondary outcome variables included necropsy findings, peritoneal fluid analysis, histologic examination, and clinical outcome. RESULTS: Fourteen swine were included in the pretrial phase and 36 in the randomized trial. Swine were survived for a mean of 9 days postoperatively. Endoscopic pressure monitoring demonstrated a reproducible change in intragastric pressure with insufflation; r = 0.735, P = .001 and r = 0.769, P < or = .000 for the total and maximum pressures, respectively. Post-peritoneoscopy, there was a detectable and significant decrease in the mean total and mean maximum pressures versus baseline (P = .006 and P = .009). There was no significant difference between the radiologic and endoscopic arms in leak detection rate (4/18 vs 3/18, respectively, P = .500). Clinical outcomes and mean weight gain were equivalent. There was 1 operative abdominal wall injury and no deaths. LIMITATIONS: Animal study. CONCLUSION: Endoscopic pressure monitoring was reproducible, demonstrated the presence of gastric leak, and was as reliable as contrast-based radiographic leak testing.


Assuntos
Gastrostomia/efeitos adversos , Animais , Meios de Contraste , Modelos Animais de Doenças , Gastroscopia , Gastrostomia/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Pressão , Radiografia , Suínos
15.
Radiology ; 250(1): 118-29, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19017924

RESUMO

PURPOSE: To evaluate the evolution of morphologic features of autoimmune pancreatitis (AIP) at computed tomography (CT) and to identify imaging features that can predict AIP response to corticosteroid therapy (CST). MATERIALS AND METHODS: This HIPAA-compliant retrospective study had institutional review board approval. From among a cohort of 63 patients with AIP, 15 patients (12 men, three women; mean age, 64.7 years; age range, 30-84 years) who underwent sequential CT examinations before treatment were included to assess the evolution of disease by reviewing pancreatic, peripancreatic, and ductal changes. Of these patients, 13 received CST and underwent posttreatment CT; these CT studies were evaluated to determine if there were imaging features that could predict response to CST. RESULTS: The disease evolved from changes of diffuse (14 of 15 patients) or focal (one of 15 patients) parenchymal swelling, peripancreatic stranding (10 of 15 patients), "halo" (nine of 15 patients), pancreatic duct changes (15 of 15 patients), and distal common bile duct narrowing (12 of 15 patients) to either resolution or development of ductal strictures and/or focal masslike swelling. In 13 patients treated with CST, favorable response to treatment was seen in those with diffuse pancreatic and peripancreatic changes. Suboptimal response was seen in patients with ductal stricture formation (two of 13 patients) and in those in whom focal masslike swellings persisted after resolution of diffuse changes (seven of 13 patients). CONCLUSION: CT features like diffuse swelling and halo respond favorably to CST and likely reflect an early inflammatory phase, whereas features like ductal strictures and focal masslike swelling are predictive of a suboptimal response and symbolize a late stage with predominance of fibrosis.


Assuntos
Anti-Inflamatórios/administração & dosagem , Doenças Autoimunes/diagnóstico por imagem , Pancreatite/diagnóstico por imagem , Prednisona/administração & dosagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Autoimunes/tratamento farmacológico , Colestase Extra-Hepática/diagnóstico por imagem , Colestase Extra-Hepática/tratamento farmacológico , Ducto Colédoco/diagnóstico por imagem , Ducto Colédoco/efeitos dos fármacos , Meios de Contraste , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Seguimentos , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Medição da Dor , Pâncreas/diagnóstico por imagem , Pâncreas/efeitos dos fármacos , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/efeitos dos fármacos , Pancreatite/tratamento farmacológico , Sensibilidade e Especificidade , Resultado do Tratamento
16.
Acad Radiol ; 15(8): 1058-68, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18620126

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this retrospective study was to compare the maximum intensity projection (MIP) images generated at a multidetector computed tomography (MDCT) scanner console using advanced tools at a three-dimensional (3D) workstation for assessment of pancreatic tumor resectability. MATERIALS AND METHODS: Institutional review board approval and informed consent wavier were obtained for this retrospective study. The intraoperative findings were used as reference standard. Two radiologists assessed console MIPs that were created using computed tomographic (CT) data sets of 30 patients (17 men and 13 women; age range, 35-79 years; mean age, 58 years) operated for pancreatic tumors. Semi-automated MIP images were created on a separate MDCT console. Two blinded radiologist (R1, R2) and surgeons (S1, S2) evaluated the image data independently for vascular involvement and tumor resectability. The image quality and diagnostic confidence for MIPs were graded on a 5-point scale (1 = poor, 2 = suboptimal, 3 = intermediate, 4 = good; 5 = excellent) and comparison was made with 3D workstation image scores. RESULTS: The findings revealed greater than 90% sensitivity, specificity, and accuracy for detecting involvement of peripancreatic vessels by pancreatic tumor with an excellent interobserver agreement (kappa = 0.87-1.00). The findings of console-generated MIPs were same as the findings of 3D workstation images. The mean of image quality and diagnostic confidence grading for console MIPs by assessors were 4.4 and 4.2, respectively. The average time to generate simple MIPs at the console was 3.4 minutes (range, 2.3-4.4) compared to 26 minutes (range, 18-33) to create images at the 3D workstation. CONCLUSION: Semi-automated MIPs generated from an MDCT scanner console is an excellent alternative to 3D workstation images for assessing resectability of pancreatic tumor based on vascular involvement. Console MIPs can be quickly generated during the time of scan and thus can improve CT workflow.


Assuntos
Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
17.
Eur Radiol ; 18(5): 868-73, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18183403

RESUMO

The purpose of the study was to compare the quality of stomach and small bowel marking/labeling using 1,350 ml of low-density barium alone (VoLumen) with 900 ml of low-density barium and 450 ml of water for 16-MDCT scans of the abdomen and pelvis and assess cost benefits with the two protocols. In this IRB approved study, 80 consecutive patients scheduled for routine CECT (contrast-enhanced CT) of the abdomen-pelvis were studied. Patients were randomized into two groups and were administered either 1,350 ml of VoLumen (two bottles at 20-min intervals, one half bottle at 50 min and the last half on the table) or 900 ml of VoLumen (two bottles at 20-min intervals and 450 ml water on the table). Portal venous phase scanning (detector collimation=0.625 mm, speed=18.75 mm, thickness=5 mm) was subsequently performed. Images were reconstructed in axial and coronal plane at the CT console. Two blinded readers used a pre-designed template to assess distension and wall characteristics of the stomach and small bowel on a 5-point scale. Median scores with the two protocols were compared using the Wilcoxon rank sum test. The stomach and small bowel labeling was rated fair to optimal in all patients and did not differ significantly in the two protocols. The mean scores for distension of the small bowel and stomach were comparable. Inter-observer agreement for bowel labeling was found to be excellent (k 0.81). With the use of coronal images there was increased reader confidence in tracing the small bowel with both protocols. Acceptance for two bottles of VoLumen and water was greater among patients as compared to three bottles of VoLumen. Use of two bottles of VoLumen and water combination cost less than three bottles of VoLumen. Stomach and small bowel labeling with administration of 900 ml of VoLumen followed by 450 ml of water is cost effective and compares well to 1,350 ml of VoLumen alone.


Assuntos
Sulfato de Bário , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Sulfato de Bário/administração & dosagem , Sulfato de Bário/economia , Meios de Contraste/administração & dosagem , Meios de Contraste/economia , Redução de Custos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Água/administração & dosagem
18.
Acad Radiol ; 14(7): 890-6, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17574138

RESUMO

RATIONALE AND OBJECTIVE: We sought to assess the accuracy of a novel computerized volumetry method, called dynamic-thresholding (DT) level set, in determining the renal volume of pigs in CT images on the basis of in vivo and ex vivo reference standards. METHODS AND MATERIALS: Eight Yorkshire breed anesthetized pigs (weight range 45-50 kg) were scanned on a 64-slice multidetector CT scanner (Sensation 64; Siemens) after injection of an iodinated (300 mg I/ml) contrast agent through an IV cannula. The kidneys of the pigs were then surgically resected and scanned by CT in the same manner. Both in vivo and ex vivo CT images were subjected to our computerized volumetry using DT level set method. The resulting volumes of the kidneys were compared with in vivo and ex vivo reference standards: the former was established by manual contouring of the kidneys on the CT images by an experienced radiologist, and the latter was established as the water displacement volume of the resected kidney. RESULTS: The comparisons of the in vivo and ex vivo measurements by our volumetric scheme with the associated reference standards yielded a mean difference of 1.73 +/- 1.24% and 3.38 +/- 2.51%, respectively. The correlation coefficients were 0.981 and 0.973 for in vivo and ex vivo comparisons, respectively. The mean difference between in vivo and ex vivo reference standards was 5.79 +/- 4.26%, and the correlation coefficient between the two standards was 0.760. CONCLUSION: Our computerized volumetry using the DT level set method can provide accurate in vivo and ex vivo measurements of kidney volume, despite a large difference between the two reference standards. This technique can be employed in human subjects for the determination of renal volume for preoperative surgical planning and assessment of oncology treatment.


Assuntos
Rim/anatomia & histologia , Rim/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste/administração & dosagem , Feminino , Imageamento Tridimensional/métodos , Iopamidol/administração & dosagem , Masculino , Tamanho do Órgão , Intensificação de Imagem Radiográfica/métodos , Padrões de Referência , Reprodutibilidade dos Testes , Suínos
19.
J Comput Assist Tomogr ; 30(5): 818-22, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16954936

RESUMO

OBJECTIVE: To evaluate the degree of enhancement and image quality of chest computed tomographic (CT) examinations on 16-slice multidetector CT using low-concentration [300 milligrams of iodine per milliliter (mg I/mL)] and high-concentration (370 mg I/mL) contrast media; to assess the impact on cost and adverse reactions of the use of high-iodine concentration contrast medium. MATERIALS AND METHODS: A total of 100 patients scheduled for routine chest CT examinations were administered nonionic contrast medium of 2 strengths: low-iodine concentration contrast medium (300 mg I/mL) [group A: n = 50; male-female ratio, 28:22; mean age, 58.4 years] and high-iodine concentration contrast medium (370 mg I/mL) (group B: n = 50; male-female ratio, 18:32; mean age, 57.6 years) with a constant amount of iodine (400 mg) injected per kilogram of body weight. Contrast media were injected using a dual injector at 2.5 mL/s followed by a 30-mL saline at 2.5 mL/s. The degree of enhancement was quantified by measuring Hounsfield unit values in different arteries and veins and was also rated on a 5-point scale for qualitative assessment. We also evaluated perivenous contrast-related artifacts. The data were compared using Mann-Whitney U test for both qualitative and quantitative enhancement ratings. A value of less than 0.05 was considered statistically significant. The value was adjusted using Bonferroni correction for statistical significance when multiple comparisons were performed. The difference in cost and the incidence of adverse reactions in both groups were calculated. RESULTS: The mean enhancement values in group B were significantly greater (P < 0.05) than those in group A. The mean Hounsfield units and standard deviation in groups A and B were aorta = 153 +/- 4, 216 +/- 20; pulmonary artery = 147 +/- 10, 208 +/- 20; superior vena cava = 155 +/- 27, 299 +/- 72; and pulmonary vein = 134 +/- 10, 215 +/- 30, respectively. The mean enhancement on a 5-point scale was greater in group B (4.2) than in group A (3.3) (P < 0.01). No significant difference between groups in perivenous artifacts was seen. Up to 5.5% savings in cost resulted from the use of a higher concentration of iodine, with no increase in adverse reactions. CONCLUSIONS: Use of higher-concentration contrast media provides a higher degree of contrast enhancement and image quality for a routine chest CT on a 16-slice multidetector CT. It also contributes to considerable cost savings with no increased risk of adverse reactions compared with low-concentration contrast media.


Assuntos
Meios de Contraste/efeitos adversos , Meios de Contraste/economia , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aortografia/métodos , Artefatos , Relação Dose-Resposta a Droga , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Iopamidol/efeitos adversos , Iopamidol/economia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Cloreto de Sódio/administração & dosagem , Veia Cava Superior/diagnóstico por imagem
20.
Eur Radiol ; 15 Suppl 4: D149-52, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16479666

RESUMO

With rapid evolution of multidetector-row CT (MDCT) technology and applications, several factors such as technology upgrade and turf battles for sharing cost and profitability affect MDCT workflow and economics. MDCT workflow optimization can enhance productivity and reduce unit costs as well as increase profitability, in spite of decrease in reimbursement rates. Strategies for workflow management include standardization, automation, and constant assessment of various steps involved in MDCT operations. In this review article, we describe issues related to MDCT economics and workflow.


Assuntos
Eficiência Organizacional , Serviço Hospitalar de Radiologia/organização & administração , Gerenciamento do Tempo , Tomografia Computadorizada por Raios X/economia , Economia Médica , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA