Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 31(2): 909-919, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32870395

RESUMO

OBJECTIVES: (1) Determine inter-observer reproducibility and test-retest repeatability of 4D flow parameters in renal allograft vessels; (2) determine if 4D flow measurements in the renal artery (RA) and renal vein (RV) can distinguish between functional and dysfunctional allografts; (3) correlate haemodynamic parameters with estimated glomerular filtration rate (eGFR), perfusion measured with dynamic contrast-enhanced MRI (DCE-MRI) and histopathology. METHODS: Twenty-five prospectively recruited renal transplant patients (stable function/chronic renal allograft dysfunction, 12/13) underwent 4D flow MRI at 1.5 T. 4D flow coronal oblique acquisitions were performed in the transplant renal artery (RA) (velocity encoding parameter, VENC = 120 cm/s) and renal vein (RV) (VENC = 45 cm/s). Test-retest repeatability (n = 3) and inter-observer reproducibility (n = 10) were assessed by Cohen's kappa, coefficient of variation (CoV) and Bland-Altman statistics. Haemodynamic parameters were compared between patients and correlated to the estimated glomerular filtration rate, DCE-MRI parameters (n = 10) and histopathology from allograft biopsies (n = 15). RESULTS: For inter-observer reproducibility, kappa was > 0.99 and 0.62 and CoV of flow was 12.6% and 7.8% for RA and RV, respectively. For test-retest repeatability, kappa was > 0.99 and 0.5 and CoV of flow was 27.3% and 59.4%, for RA and RV, respectively. RA (p = 0.039) and RV (p = 0.019) flow were both significantly reduced in dysfunctional allografts. Both identified chronic allograft dysfunction with good diagnostic performance (RA: AUC = 0.76, p = 0.036; RV: AUC = 0.8, p = 0.018). RA flow correlated negatively with histopathologic interstitial fibrosis score ci (ρ = - 0.6, p = 0.03). CONCLUSIONS: 4D flow parameters had better repeatability in the RA than in the RV. RA and RV flow can identify chronic renal allograft dysfunction, with RA flow correlating with histopathologic interstitial fibrosis score. KEY POINTS: • Inter-observer reproducibility of 4D flow measurements was acceptable in both the transplant renal artery and vein, but test-retest repeatability was better in the renal artery than in the renal vein. • Blood flow measurements obtained with 4D flow MRI in the renal artery and renal vein are significantly reduced in dysfunctional renal transplants. • Renal transplant artery flow correlated negatively with histopathologic interstitial fibrosis score.


Assuntos
Nefropatias/diagnóstico por imagem , Transplante de Rim , Adulto , Idoso , Biópsia , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Taxa de Filtração Glomerular , Hemodinâmica , Humanos , Nefropatias/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
2.
Radiol Imaging Cancer ; 2(4): e190094, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32803165

RESUMO

Purpose: To quantify diffusion and perfusion changes in hepatocellular carcinoma (HCC) induced by yttrium 90 (90Y) radioembolization and to assess the value of dynamic contrast material-enhanced (DCE) MRI and intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) for predicting HCC response. Materials and Methods: Institutional review board approval was obtained for this prospective study (clinical trial registry NCT01871545). Twenty-four participants with HCC (mean age, 69 years ± 9 [standard deviation], 18 men) underwent multiparametric MRI, including IVIM DWI and gadoxetic acid DCE MRI before (n = 24) and 6 weeks (n = 21) after radioembolization. IVIM DWI and DCE MRI histogram parameters were quantified in HCCs and liver parenchyma. HCC response was assessed by using modified Response Evaluation Criteria in Solid Tumors at 6 weeks and 6-12 months after radioembolization. Logistic regression analysis was used to evaluate the diagnostic performance of baseline MRI and clinical parameters for prediction of response. Results: Twenty-five HCCs were analyzed (mean size, 3.6 cm ± 1.9). Radioembolization resulted in significantly decreased perfusion (DCE MRI arterial flow, P = .002; IVIM pseudodiffusion coefficient [D*], P = .014). Multivariate logistic regression selected combined serum α-fetoprotein and portal flow (F p ) skewness (area under the curve [AUC] = 0.924) and combined D* standard deviation and F p kurtosis (AUC = 0.916) for prediction of objective and complete response at 6 weeks, respectively. Standard deviation of DCE MRI parameter arterial fraction was selected as the optimal predictor for complete response at 6-12 months (AUC = 0.857). Conclusion: Diffusion and perfusion MRI can be used to evaluate the response of HCC to radioembolization. Pretreatment DCE MRI histogram parameters may be useful for radioembolization treatment stratification. Supplemental material is available for this article. © RSNA, 2020.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Meios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Radioisótopos de Ítrio
3.
Eur Radiol ; 30(11): 6003-6013, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32588209

RESUMO

OBJECTIVES: The primary objective was to compare the performance of 3 different abbreviated MRI (AMRI) sets extracted from a complete gadoxetate-enhanced MRI obtained for hepatocellular carcinoma (HCC) screening. Secondary objective was to perform a preliminary cost-effectiveness analysis, comparing each AMRI set to published ultrasound performance for HCC screening in the USA. METHODS: This retrospective study included 237 consecutive patients (M/F, 146/91; mean age, 58 years) with chronic liver disease who underwent a complete gadoxetate-enhanced MRI for HCC screening in 2017 in a single institution. Two radiologists independently reviewed 3 AMRI sets extracted from the complete exam: non-contrast (NC-AMRI: T2-weighted imaging (T2wi)+diffusion-weighted imaging (DWI)), dynamic-AMRI (Dyn-AMRI: T2wi+DWI+dynamic T1wi), and hepatobiliary phase AMRI (HBP-AMRI: T2wi+DWI+T1wi during the HBP). Each patient was classified as HCC-positive/HCC-negative based on the reference standard, which consisted in all available patient data. Diagnostic performance for HCC detection was compared between sets. Estimated set characteristics, including historical ultrasound data, were incorporated into a microsimulation model for cost-effectiveness analysis. RESULTS: The reference standard identified 13/237 patients with HCC (prevalence, 5.5%; mean size, 33.7 ± 30 mm). Pooled sensitivities were 61.5% for NC-AMRI (95% confidence intervals, 34.4-83%), 84.6% for Dyn-AMRI (60.8-95.1%), and 80.8% for HBP-AMRI (53.6-93.9%), without difference between sets (p range, 0.06-0.16). Pooled specificities were 95.5% (92.4-97.4%), 99.8% (98.4-100%), and 94.9% (91.6-96.9%), respectively, with a significant difference between Dyn-AMRI and the other sets (p < 0.01). All AMRI methods were effective compared with ultrasound, with life-year gain of 3-12 months against incremental costs of US$ < 12,000. CONCLUSIONS: NC-AMRI has limited sensitivity for HCC detection, while HBP-AMRI and Dyn-AMRI showed excellent sensitivity and specificity, the latter being slightly higher for Dyn-AMRI. Cost-effectiveness estimates showed that AMRI is effective compared with ultrasound. KEY POINTS: • Comparison of different abbreviated MRI (AMRI) sets reconstructed from a complete gadoxetate MRI demonstrated that non-contrast AMRI has low sensitivity (61.5%) compared with contrast-enhanced AMRI (80.8% for hepatobiliary phase AMRI and 84.6% for dynamic AMRI), with all sets having high specificity. • Non-contrast and hepatobiliary phase AMRI can be performed in less than 14 min (including set-up time), while dynamic AMRI can be performed in less than 17 min. • All AMRI sets were cost-effective for HCC screening in at-risk population in comparison with ultrasound.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/complicações , Doença Crônica , Meios de Contraste , Análise Custo-Benefício , Imagem de Difusão por Ressonância Magnética/economia , Imagem de Difusão por Ressonância Magnética/métodos , Detecção Precoce de Câncer/métodos , Feminino , Gadolínio DTPA , Humanos , Hepatopatias , Neoplasias Hepáticas/complicações , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA