Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Biomed Chromatogr ; 37(8): e5641, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37041119

RESUMO

A sensitive, rapid, reproducible, and economical HPLC method is reported for the quantification of raloxifene hydrochloride employing Quality by Design (QbD) principles. Factor screening studies, employing Taguchi design, indicated buffer volume percentage and isocratic flow rate as the critical method parameters (CMPs), which significantly influence the chosen critical analytical attributes, that is, tailing factor and theoretical plate number. Method conditions were subsequently optimized using face-centered cubic design with magnitude of variance inflation factor for assessing multicollinearity among CMPs. Method operable design region (MODR) was earmarked and liquid chromatographic separation optimized using 0.05 M citrate buffer, acetonitrile, and methanol (57:40:3 v/v/v) as ggmobile phase at 0.9 mL min-1 flow rate, λmax of 280 nm, and column temperature of 40°C. Validation of the developed analytical method was accomplished as per International Council on Harmonization (ICH) guidelines confirming high levels of linearity, precision, accuracy, robustness, and sensitivity. Application of Monte Carlo simulations enabled the attainment of best plausible chromatographic resolution and corroboration of the demarcated MODR. Establishment and validation of the bioanalytical method using rat plasma samples, along with forced degradation and stability studies, corroborated the aptness of developed HPLC methods for drug quantification in the biological fluids, as well as in bulk and marketed dosage forms.


Assuntos
Cloridrato de Raloxifeno , Animais , Ratos , Método de Monte Carlo , Reprodutibilidade dos Testes , Limite de Detecção , Cromatografia Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos
2.
Pharmaceutics ; 14(11)2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36365213

RESUMO

The study was initiated with two major purposes: investigating the role of isomalt (GIQ9) as a pharmaceutical carrier for solid self-nanoemulsifying drug delivery systems (S-SNEDDSs) and improving the oral bioavailability of lipophilic curcumin (CUN). GIQ9 has never been explored for solidification of liquid lipid-based nanoparticles such as a liquid isotropic mixture of a SNEDDS containing oil, surfactant and co-surfactant. The suitability of GIQ9 as a carrier was assessed by calculating the loading factor, flow and micromeritic properties. The S-SNEDDSs were prepared by surface adsorption technique. The formulation variables were optimized using central composite design (CCD). The optimized S-SNEDDS was evaluated for differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), microscopy, dissolution and pharmacokinetic studies. The S-SNEDDS showed a particle size, zeta potential and PDI of 97 nm, -26.8 mV and 0.354, respectively. The results of DSC, XRD, FTIR and microscopic studies revealed that the isotropic mixture was adsorbed onto the solid carrier. The L-SNEDDS and S-SNEDDS showed no significant difference in drug release, indicating no change upon solidification. The optimized S-SNEDDS showed 5.1-fold and 61.7-fold enhancement in dissolution rate and oral bioavailability as compared to the naïve curcumin. The overall outcomes of the study indicated the suitability of GIQ9 as a solid carrier for SNEDDSs.

3.
J AOAC Int ; 104(3): 620-632, 2021 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-33528003

RESUMO

BACKGROUND: Ceftazidime, a third-generation cephalosporin, is widely used in the treatment of lung infections, often given as "off-label" nebulization. There is a need to develop a sensitive and robust analytical method to compute aerodynamic properties of ceftazidime following nebulization. OBJECTIVE: The current study entails development of a simple, accurate, and sensitive HPLC method for ceftazidime estimation, employing the principles of analytical quality-by-design (AQbD) and Monte Carlo simulations. METHOD: Selection of critical material attributes (CMAs) affecting method performance was accomplished by factor screening exercises. Subsequently, the influential CMAs, i.e., mobile phase ratio and flow rate, were systemically optimized using a face-centered cubic design for the chosen critical analytical attributes (CAAs). The factor relationship(s) between CMAs and CAAs was explored employing a 3 D-response surface and 2 D-contour plots, followed by numerical as well as graphical optimization, for establishing the optimal chromatographic conditions. The obtained method operable design region was validated by Monte Carlo simulations for defect rate analysis. RESULTS: The optimized HPLC conditions for estimating ceftazidime were acetonitrile to acetic acid solution (75:25) as mobile phase at a flow rate of 0.7 mL/min, leading to Rt of 4.5 min and peak tailing ≤2. Validation studies, as per International Conference on Harmonization Q2(R1) guidance, demonstrated high sensitivity, accuracy, and efficiency of the developed analytical method with an LOD of 0.075 and LOQ of 0.227 µg/mL. Application of this chromatographic method was extrapolated for determining aerodynamic performance by nebulizing ceftazidime at a flow rate of 15 L/min using a next-generation impactor. The study indicated superior performance, sensitivity, and specificity of the developed analytical system for quantifying ceftazidime. CONCLUSIONS: Application of an AQbD approach, coupled with Monte Carlo simulations, aided in developing a robust HPLC method for estimationof ceftazidime per se and on various stages of impactor. HIGHLIGHTS: (i) QbD-enabled development of robust RP-HPLC method for ceftazidime quantification, (ii) Analytical method optimization employing Risk Assessment and Design of Experiments, (iii) Design space verification and defect rate analysis using Monte Carlo simulations, (iv) Chromatographic method validation as per ICH Q2 R1 guidelines and (v) Quantitative estimation of ceftazidime on various stages of impactor.


Assuntos
Ceftazidima , Cromatografia Líquida de Alta Pressão , Limite de Detecção , Método de Monte Carlo , Reprodutibilidade dos Testes
4.
Artigo em Inglês | MEDLINE | ID: mdl-32771967

RESUMO

The present work describes the systematic development of a simple, rapid, sensitive, robust, effective and cost-effective reversed-phase high performance liquid chromatographic method for quantitative analysis of ferulic acid using analytical quality by design paradigms. Initially, apt wavelength for the analysis of ferulic acid was selected employing principal component analysis as the chemometric tool. An Ishikawa fishbone diagram was constructed to delineate various plausible variables influencing analytical target profile, viz. peak area, theoretical plate count, retention time and peak tailing as the critical analytical attributes. Risk assessment using risk estimation matrix and factor screening studies employing Taguchi design aided in demarcating two critical method parameters, viz. mobile phase ratio and flow rate affecting critical analytical attributes. Subsequently, the optimum operational conditions of the liquid chromatographic method were delineated using face-centred composite design. Multicollinearity among the chosen factors for optimization was analyzed by the magnitude of variance inflation factor optimized analytical design space, providing optimum method performance, was earmarked using numerical and graphical optimization and corroborated using Monte Carlo simulations. Validation, as per the ICH Q2(R1) guidelines, ratified the efficiency and sensitivity of the developed novel analytical method of ferulic acid in the mobile phase and the human plasma matrix. The optimal method used a mobile phase, comprising of acetonitrile: water (47:53% v/v, pH adjusted to 3.0 with glacial acetic acid), at a flow rate of 0.8 mL·min-1, at a λmax of 322 nm using a C18 column. Use of principal component analysis unearthed the suitable wavelength for analysis, while analytical quality by design approach, along with Monte Carlo simulations, facilitated the identification of influential variables in obtaining the "best plausible" validated chromatographic solution for efficient quantification of ferulic acid.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Ácidos Cumáricos/sangue , Ácidos Cumáricos/química , Humanos , Limite de Detecção , Modelos Lineares , Método de Monte Carlo , Análise de Componente Principal , Reprodutibilidade dos Testes