Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Environ Manage ; 164: 104-13, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26363257

RESUMO

Molasses wastewater is a high strength effluent of food industry such as distilleries, sugar and yeast production plants etc. It is characterized by a dark brown color and exhibits a high content in substances of recalcitrant nature such as melanoidins. In this study, electrocoagulation (EC) was studied as a post treatment step for biologically treated molasses wastewater with high nitrogen content obtained from a baker's yeast industry. Iron and copper electrodes were used in various forms; the influence and interaction of current density, molasses wastewater dilution, and reaction time, on COD, color, ammonium and nitrate removal rates and operating cost were studied and optimized through Box Behnken's response surface analysis. Reaction time varied from 0.5 to 4 h, current density varied from 5 to 40 mA/cm(2) and dilution from 0 to 90% (v/v expressed as water concentration). pH, conductivity and temperature measurements were also carried out during each experiment. From preliminary experiments, it was concluded that the application of aeration and sample dilution, considerably influenced the kinetics of the process. The obtained results showed that COD removal varied between 10 and 54%, corresponding to an operation cost ranging from 0.2 to 33 euro/kg COD removed. Significant removal rates were obtained for nitrogen as nitrate and ammonium (i.e. 70% ammonium removal). A linear relation of COD and ammonium to the design parameters was observed, while operation cost and nitrate removal responded in a curvilinear function. A low ratio of electrode surface to treated volume was used, associated to a low investment cost; in addition, iron wastes could be utilized as low cost electrodes i.e. iron fillings from lathes, aiming to a low operation cost due to electrodes replacement. In general, electrocoagulation proved to be an effective and low cost process for biologically treated molasses-wastewater treatment for additional removal of COD and nitrogen content and color reduction. Treated effluent samples with good quality were produced by EC, with COD, NH4-N and NO3-N concentrations of 180, 52 and 2 mg/l respectively. Response surface analysis revealed that optimized conditions could be established under moderate molasses wastewater dilution, (e.g. 45%), at 3.5 h treatment time and 33 mA/cm(2) current density.


Assuntos
Eletrocoagulação/métodos , Melaço , Eliminação de Resíduos Líquidos/métodos , Análise da Demanda Biológica de Oxigênio , Cor , Cobre , Custos e Análise de Custo , Eletrocoagulação/economia , Eletrocoagulação/instrumentação , Eletrodos/economia , Indústria Alimentícia , Concentração de Íons de Hidrogênio , Resíduos Industriais , Ferro/química , Nitratos , Temperatura , Eliminação de Resíduos Líquidos/economia , Águas Residuárias
2.
Ecotoxicol Environ Saf ; 84: 212-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22858104

RESUMO

The environmental hazard of six coal fly ash samples collected from various coal incineration plants were examined in the present study, using various leaching tests along with physicochemical and ecotoxicological analyses. Physicochemical analyses indicated that the concentration of Ba, Cr, Mo, Se, sulfates and total dissolved solids (TDS) exceeded the threshold values, according to the European Council decision 2003/33/EC for inert, non-hazardous or hazardous waste. The highest sensitivity, among examined organisms, was presented by Daphnia magna and was ascribed to the lowest tolerance of the organism to Cr. The toxic effect profile of the leachates toward Vibrio fischeri revealed that its bioluminescence was significantly altered by the presence of heavy metals in the leachates (such as Cu, Ni and Zn) in low or sub-lethal doses. Although the toxicity of the leachates toward Pseudokirchneriella subcapitata was relatively high, the correlation between the toxicity and heavy metals concentration was rather poor, indicating the significance of the bioavailability of constituents and the importance of toxicity testing. Based on the classification of the samples resulted by physicochemical analyses of the leachates and the results of ecotoxicity tests, Physicochemical and Ecotoxicological indices were also defined, for an overall evaluation of the environmental impact assessment of fly ashes. The suggested indices showed that ecotoxicity tests were in some cases inconsistent with the outcome of waste classification based on physicochemical analyses. Moreover, the examination of leaching protocols and obtained results showed that one stage leaching test (L/S=10 L/kg) underestimated the fly ash classification, when compared with the two stage test EN 12457-3 at the cumulative ratio L/S=10 L/kg. In addition, the application of availability test NEN 7341 provided useful results about the ecotoxicity wastes. Thus, NEN 7341 is strongly suggested for the implementation of such studies, since the bioavailability of constituents may not be altered by pH adjustment tactics and pH-originated toxicity effects may be avoided.


Assuntos
Aliivibrio fischeri/efeitos dos fármacos , Clorófitas/efeitos dos fármacos , Cinza de Carvão/toxicidade , Daphnia/efeitos dos fármacos , Ecotoxicologia , Animais , Cinza de Carvão/química , Poluentes Ambientais/química , Poluentes Ambientais/toxicidade , Metais Pesados/análise , Metais Pesados/toxicidade , Testes de Toxicidade/normas
3.
Waste Manag ; 30(2): 251-62, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19861235

RESUMO

In Greece more than 14,000 tonnes of infectious hospital waste are produced yearly; a significant part of it is still mismanaged. Only one off-site licensed incineration facility for hospital wastes is in operation, with the remaining of the market covered by various hydroclave and autoclave units, whereas numerous problems are still generally encountered regarding waste segregation, collection, transportation and management, as well as often excessive entailed costs. Everyday practices still include dumping the majority of solid hospital waste into household disposal sites and landfills after sterilization, still largely without any preceding recycling and separation steps. Discussed in the present paper are the implemented and future treatment practices of infectious hospital wastes in Central Macedonia; produced quantities are reviewed, actual treatment costs are addressed critically, whereas the overall situation in Greece is discussed. Moreover, thermal treatment processes that could be applied for the treatment of infectious hospital wastes in the region are assessed via the multi-criteria decision method Analytic Hierarchy Process. Furthermore, a sensitivity analysis was performed and the analysis demonstrated that a centralized autoclave or hydroclave plant near Thessaloniki is the best performing option, depending however on the selection and weighing of criteria of the multi-criteria process. Moreover the study found that a common treatment option for the treatment of all infectious hospital wastes produced in the Region of Central Macedonia, could offer cost and environmental benefits. In general the multi-criteria decision method, as well as the conclusions and remarks of this study can be used as a basis for future planning and anticipation of the needs for investments in the area of medical waste management.


Assuntos
Eliminação de Resíduos de Serviços de Saúde/métodos , Tomada de Decisões , Economia Hospitalar , Grécia , Humanos , Incineração/estatística & dados numéricos , Resíduos de Serviços de Saúde/estatística & dados numéricos , Esterilização/estatística & dados numéricos
4.
Ultraschall Med ; 30(5): 478-84, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19813157

RESUMO

PURPOSE: Transient elastography (FibroScan, [TE]) and serum fibrosis markers such as the FibroTest (FT) are established methods for the noninvasive staging of liver fibrosis. A study using real-time elastography (HI-RTE), which is integrated in a conventional ultrasound system, was recently published with comparable results to transient elastography. The aim of the present study was to validate real-time elastography using the formulas calculated in previous studies and to compare the results to transient elastography and FibroTest for the noninvasive assessment of liver fibrosis. MATERIALS AND METHODS: One hundred and thirty-four patients with chronic liver disease and either histological assessment of liver fibrosis (n = 112) or proven liver cirrhosis (n = 22) were included in the study. All patients received TE, HI-RTE, and biochemical evaluation on the same day as presentation. The calculation of the elasticity score of real-time elastography was performed in accordance with the two previously published studies. RESULTS: The Spearman correlation coefficient between transient elastography, real-time elastography and FibroTest with the histological Chevallier score was statistically significant with 0.78, 0.34, and 0.67, respectively (p < 0.01). The diagnostic accuracy expressed as areas under ROC curves was 0.84, 0.69 and 0.85 for the diagnosis of significant fibrosis (F > or = 2), and 0.97, 0.65, and 0.83 for the diagnosis of cirrhosis, respectively. CONCLUSION: Real-time elastography in its present form cannot replace transient elastography for noninvasive assessment of liver fibrosis.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Alanina Transaminase/sangue , Aspartato Aminotransferases/sangue , Biópsia , Doença Crônica , Técnicas de Imagem por Elasticidade/métodos , Humanos , Cirrose Hepática/sangue , Cirrose Hepática/patologia , Hepatopatias/sangue , Hepatopatias/patologia
5.
Water Sci Technol ; 57(6): 947-53, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18413958

RESUMO

The aim of this work was to examine the ecotoxicity of reclaimed wastewater by the use of bioassays and the determination of immunological parameters. Secondary and tertiary mucicipal wastewater samples were examined for their physicochemical and microbiological characteristics as well as for their endotoxin concentrations. The ecotoxicological characteristics were assessed by a battery of bioassays, using Vibrio fischeri, Daphnia magna and Tetrahymena thermophilla as test species and phytotoxicity. The mitogenic responses of mouse splenocytes were as well used as bioassay. The cytokines of IL-1, IL-2, IL-10, IFNgamma and TNFalpha, were also determined in the supernatant of splenocyte cultures and served as molecular biomarkers. All bioassays exhibited decrease of the ecotoxicological responses after tertiary treatment. However, mitogenic responses were proved to be more sensitive. IL-1 increased, while IL-2 production was unaffected. The fact that IL-10 production increased in response to secondary treated effluents in conjunction with the increased endotoxin levels, suggest Th2 type immune responses. Although results obtained from the toxicity bioassays after the tertiary treatment showed comparable results to those of controls, cytokine levels indicated the induction of immune response even after tertiary treatment. Consequently, cytokine production could be used as a sensitive biomarker for the evaluation of treatment efficiency of the reclaimed wastewaters intended for reuse.


Assuntos
Bioensaio/métodos , Biomarcadores/análise , Poluentes Químicos da Água/toxicidade , Abastecimento de Água/análise , Aliivibrio fischeri/efeitos dos fármacos , Animais , Células Cultivadas , Daphnia/efeitos dos fármacos , Ecotoxicologia/métodos , Interferon gama/análise , Interleucina-1/análise , Interleucina-10/análise , Interleucina-2/análise , Camundongos , Baço/citologia , Baço/metabolismo , Tetrahymena/efeitos dos fármacos , Fator de Necrose Tumoral alfa/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA