RESUMO

The adsorption and desorption behavior of volatile nitrogen-containing compounds in vapor phase by solid-phase microextraction Arrow (SPME-Arrow) and in-tube extraction (ITEX) sampling systems, were investigated experimentally using gas chromatography-mass spectrometry. Three different SPME-Arrow coating materials, DVB/PDMS, MCM-41, and MCM-41-TP and two ITEX adsorbents, TENAX-GR and MCM-41-TP were compared to clarify the selectivity of the sorbents towards nitrogen-containing compounds. In addition, saturated vapor pressures for these compounds were estimated, both experimentally and theoretically. In this study, the adsorption of nitrogen-containing compounds on various adsorbents followed the Elovich model well, while a pseudo-first-order kinetics model best described the desorption kinetics. Pore volume and pore sizes of the coating sorbents were essential parameters for the determination of the adsorption performance for the SPME-Arrow sampling system. MCM-41-TP coating with the smallest pore size gave the slowest adsorption rate compared to that of DVB/PDMS and MCM-41 in the SPME-Arrow sampling system. Both adsorbent and adsorbate properties, such as hydrophobicity and basicity, affected the adsorption and desorption kinetics in SPME-Arrow system. The adsorption and desorption rates of studied C6H15N isomers in the MCM-41 and MCM-41-TP sorbent materials of SPME-Arrow system were higher for dipropylamine and triethylamine (branched amines) than for hexylamine (linear chain amines). DVB/PDMS-SPME-Arrow gave fast adsorption rates for the aromatic-ringed pyridine and o-toluidine. All studied nitrogen-containing compounds demonstrated high desorption rates with DVB/PDMS-SPME-Arrow. Chemisorption and physisorption were the sorption mechanisms in MCM-41- and MCM-41-TP- SPME-Arrow, but additional experiments are needed to confirm this. An active sampling technique ITEX gave comparable adsorption and desorption rates on the selective MCM-41-TP and universal TENAX-GR sorbent materials for all the compounds studied. Vapor pressures of nitrogen-containing compounds were experimentally estimated by using retention index approach and these values were compared with the theoretical ones, calculated using the COnductor-like Screening MOdel for Real Solvent (COSMO-RS) model. Both values agreed well with those found in the literature proving that these methods can be successfully used in predicting VOC's vapor pressures, e.g. for the formation of secondary organic aerosols.


Assuntos
Gases , Compostos de Nitrogênio , Aminas/análise , Microextração em Fase Sólida/métodos , Nitrogênio
2.
J Pharm Biomed Anal ; 129: 273-281, 2016 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-27442889

RESUMO

Quality Control methods (QC-methods) play an important role in the overall control strategy for drug manufacturing. However, efficient life-cycle management and continual improvement are hindered due to a variety of post-approval variation legislations across territories and a lack of harmonization of the requirements. As a result, many QC-methods fall behind the technical development. Developing the QC-method in accordance with the Quality by Design guidelines gives the possibility to do continual improvements inside the original Method Operable Design Region (MODR). However, often it is necessary to do changes outside the MODR, e.g. to incorporate new technology that was not available at the time the original method was development. Here, we present a method enhancement concept which allows minor adjustments, within the same measuring principle, outside the original MODR without interaction with regulatory agencies. The feasibility of the concept is illustrated by a case study of a QC-method based on HPLC, assumed to be developed before the introduction of UHPLC, where the switch from HPLC to UHPLC is necessary as a continual improvement strategy. The concept relies on the assumption that the System Suitability Test (SST) and failure modes are relevant for other conditions outside the MODR as well when the same measuring principle is used. It follows that it should be possible to move outside the MODR as long as the SST has passed. All minor modifications of the original, approved QC-method must be re-validated according to a template given in the original submission and a statistical equivalence should be shown between the original and modified QC-methods. To summarize, revalidation is handled within the pharmaceutical quality control system according to internal change control procedures, but without interaction with regulating agencies.


Assuntos
Indústria Farmacêutica/normas , Preparações Farmacêuticas/normas , Cromatografia Líquida de Alta Pressão/métodos , Controle de Qualidade , Melhoria de Qualidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-17070119

RESUMO

A simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the simultaneous determination of yield and conversion ratio of 4-nitro-1,8-naphthalic anhydride to 4-amino-1,8-naphthalic anhydride following incubation with a crude bakers' yeast homogenate. The analytes were separated on a C18 column in gradient mode. The detection limit of 4-amino-1,8-naphthalic anhydride is 10ng/microl when using a 10microl sample injection volume. The nitroreductase activity in the homogenate system can be assessed during the bioconversion process. The method can be used for the simultaneous detection of 4-hydroxylamino-1,8-naphthalic anhydride, an intermediate with limited stability.


Assuntos
Anidridos/química , Cromatografia Líquida de Alta Pressão/métodos , Nitrorredutases/metabolismo , Saccharomyces cerevisiae/metabolismo , Anidridos/síntese química , Estrutura Molecular , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta