Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Hepatol ; 74(4): 881-892, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32976864

RESUMO

BACKGROUND & AIMS: Early allograft dysfunction (EAD) following liver transplantation (LT) negatively impacts graft and patient outcomes. Previously we reported that the liver graft assessment following transplantation (L-GrAFT7) risk score was superior to binary EAD or the model for early allograft function (MEAF) score for estimating 3-month graft failure-free survival in a single-center derivation cohort. Herein, we sought to externally validate L-GrAFT7, and compare its prognostic performance to EAD and MEAF. METHODS: Accuracies of L-GrAFT7, EAD, and MEAF were compared in a 3-center US validation cohort (n = 3,201), and a Consortium for Organ Preservation in Europe (COPE) normothermic machine perfusion (NMP) trial cohort (n = 222); characteristics were compared to assess generalizability. RESULTS: Compared to the derivation cohort, patients in the validation and NMP trial cohort had lower recipient median MELD scores; were less likely to require pretransplant hospitalization, renal replacement therapy or mechanical ventilation; and had superior 1-year overall (90% and 95% vs. 84%) and graft failure-free (88% and 93% vs. 81%) survival, with a lower incidence of 3-month graft failure (7.4% and 4.0% vs. 11.1%; p <0.001 for all comparisons). Despite significant differences in cohort characteristics, L-GrAFT7 maintained an excellent validation AUROC of 0.78, significantly superior to binary EAD (AUROC 0.68, p = 0.001) and MEAF scores (AUROC 0.72, p <0.001). In post hoc analysis of the COPE NMP trial, the highest tertile of L-GrAFT7 was significantly associated with time to liver allograft (hazard ratio [HR] 2.17, p = 0.016), Clavien ≥IIIB (HR 2.60, p = 0.034) and ≥IVa (HR 4.99, p = 0.011) complications; post-LT length of hospitalization (p = 0.002); and renal replacement therapy (odds ratio 3.62, p = 0.016). CONCLUSIONS: We have validated the L-GrAFT7 risk score as a generalizable, highly accurate, individualized risk assessment of 3-month liver allograft failure that is superior to existing scores. L-GrAFT7 may standardize grading of early hepatic allograft function and serve as a clinical endpoint in translational studies (www.lgraft.com). LAY SUMMARY: Early allograft dysfunction negatively affects outcomes following liver transplantation. In independent multicenter US and European cohorts totaling 3,423 patients undergoing liver transplantation, the liver graft assessment following transplantation (L-GrAFT) risk score is validated as a superior measure of early allograft function that accurately discriminates 3-month graft failure-free survival and post-liver transplantation complications.


Assuntos
Transplante de Fígado , Disfunção Primária do Enxerto , Medição de Risco , Europa (Continente)/epidemiologia , Feminino , Sobrevivência de Enxerto , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Transplante de Fígado/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Disfunção Primária do Enxerto/diagnóstico , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/terapia , Prognóstico , Traumatismo por Reperfusão/diagnóstico , Traumatismo por Reperfusão/epidemiologia , Traumatismo por Reperfusão/terapia , Reprodutibilidade dos Testes , Medição de Risco/métodos , Medição de Risco/normas , Fatores de Risco , Análise de Sobrevida , Estados Unidos/epidemiologia
2.
Water Sci Technol ; 75(3-4): 890-897, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28234289

RESUMO

With the MBBR IFAS (moving bed biofilm reactor integrated fixed-film activated sludge) process, the biomass required for biological wastewater treatment is either suspended or fixed on free-moving plastic carriers in the reactor. Coarse- or fine-bubble aeration systems are used in the MBBR IFAS process. In this study, the oxygen transfer efficiency (OTE) of a coarse-bubble aeration system was improved significantly by the addition of the investigated carriers, even in-process (∼1% per vol-% of added carrier material). In a fine-bubble aeration system, the carriers had little or no effect on OTE. The effect of carriers on OTE strongly depends on the properties of the aeration system, the volumetric filling rate of the carriers, the properties of the carrier media, and the reactor geometry. This study shows that the effect of carriers on OTE is less pronounced in-process compared to clean water conditions. When designing new carriers in order to improve their effect on OTE further, suppliers should take this into account. Although the energy efficiency and cost effectiveness of coarse-bubble aeration systems can be improved significantly by the addition of carriers, fine-bubble aeration systems remain the more efficient and cost-effective alternative for aeration when applying the investigated MBBR IFAS process.


Assuntos
Biofilmes/crescimento & desenvolvimento , Reatores Biológicos/microbiologia , Oxigênio/análise , Esgotos , Águas Residuárias/química , Purificação da Água/métodos , Biomassa , Reatores Biológicos/economia , Conservação de Recursos Energéticos , Oxigênio/química , Esgotos/química , Esgotos/microbiologia , Purificação da Água/economia
3.
J Dent ; 51: 49-55, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27263031

RESUMO

OBJECTIVES: Intra-oral pH plays an important role in the pathogenesis of tooth erosion and decay, but there is limited information about its variation in real life settings. The aims of this research were to: 1) develop a wireless device, which can be used to continuously monitor intra-oral pH and temperature in real-time; 2) test and validate the device under controlled laboratory conditions; and 3) collect data in a natural environment in a sample of healthy volunteers. METHODS: A wireless device for measuring pH and temperature simultaneously was developed, calibrated and validated against the gold standard glass electrode pH meter. A smart phone was used as data logger. The wireless device was embedded in an oral appliance and worn by eleven participants (mean age 31.1±6.9years) for 24h, while conducting standardised drinking tasks and regular daily activities. RESULTS: The wireless device could accurately measure pH and temperature both in vitro and in vivo. The recovery time following the swallow of a standard acidic drink varied markedly among individuals (mean=1.3±0.9min). The intra-oral pH and temperature recorded in the natural environment also showed a large inter- and intra-individual variability. The average intra-oral pH when asleep (6.7±0.5) was lower (p<0.001) than when awake (7.2±0.5). The average intra-oral temperature during sleep (35.6±0.5°C) was higher (p<0.001) than when awake (34.5±0.7°C). CONCLUSIONS: Intra-oral pH and temperature can be continuously and wirelessly assessed in real-life settings, and show individual-specific patterns with circadian variations. Intra-oral pH becomes slightly acidic during sleep while intra-oral temperature increases and fluctuates less. CLINICAL SIGNIFICANCE: We propose a wireless device that is capable of measuring intra-oral pH over a 24-h period. We found marked inter-individual variation after acidic stimuli, and day to sleep time variation of both intra-oral temperature and pH. Our approach may provide new insight into the relationship between oral pH, tooth wear and decay.


Assuntos
Temperatura Corporal , Ácidos , Adulto , Humanos , Sono , Erosão Dentária , Adulto Jovem
4.
Org Biomol Chem ; 10(5): 958-65, 2012 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-22130967

RESUMO

Protein profiling probes are important tools for studying the composition of the proteome and as such have contributed greatly to the understanding of various complex biological processes in higher organisms. For this purpose the application of fluorescently labeled activity or affinity probes is highly desirable. Especially for in vivo detection of low abundant target proteins, otherwise difficult to analyse by standard blotting techniques, fluorescently labeled profiling probes are of high value. Here, a one-pot protocol for the synthesis of activated fluorescent labels (i.e. azide, alkynyl or NHS), based on the Ugi-4-component reaction (Ugi-4CR), is presented. As a result of the peptoidic structure formed, the fluorescent properties of the products are pH insensitive. Moreover, the applicability of these probes, as exemplified by the labeling of model protein BSA, will be discussed.


Assuntos
Corantes Fluorescentes/síntese química , Rodaminas/síntese química , Animais , Bovinos , Técnicas de Química Sintética/economia , Técnicas de Química Sintética/métodos , Corantes Fluorescentes/química , Modelos Moleculares , Proteômica , Rodaminas/química , Soroalbumina Bovina/análise
5.
South Med J ; 100(12): 1208-13, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18090963

RESUMO

The use of living donor kidneys has dramatically increased the number and success of kidney transplants across the world. But questions remain regarding the subjection of a healthy individual to surgery for the benefit of another. Donors do have medical and financial risks. The stigma of organ brokering remains today, with evidence of commercial transplantation in other countries. Here in the US, we are exposed to advertising for donors using the media. In the hope of increasing living donations, we run the risk of stretching altruism too far. In this manuscript, we highlight and discuss some of the current controversies surrounding living donor kidney transplantation across the world.


Assuntos
Transplante de Rim , Doadores Vivos , Publicidade , Compensação e Reparação , Humanos , Internacionalidade , Transplante de Rim/efeitos adversos , Transplante de Rim/ética , Transplante de Rim/legislação & jurisprudência , Doadores Vivos/ética , Doadores Vivos/legislação & jurisprudência , Meios de Comunicação de Massa , Medição de Risco , Doadores de Tecidos/ética
6.
Transplantation ; 73(10): 1593-7, 2002 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-12042645

RESUMO

INTRODUCTION: Adult-to-adult living donor liver transplants are being increasingly performed. Although considerable data are available on the quality of life after kidney donation, there is little comparable information on liver donors. METHODS: Between August 1998 and July 2000, 48 adults received liver grafts from living donors. At least 2 months after donation, donors were mailed a structured questionnaire and the standardized Medical Outcomes Study Short-Form Health Survey (SF-36), a generic measure assessing health-related quality of life outcomes using eight scales: mental health, emotional limits, vitality, social function, physical function, physical limits, pain, general health. RESULTS: Thirty donors (62.5%) responded at a mean of 280+/-157 days after donation. Fifteen (50%) of their recipients had major complications (two deaths, four retransplants, nine biliary complications). Regarding overall satisfaction, all said they would donate again. Compared to published U.S. norms (n=2474), our group of donors scored higher than the general population in seven of eight domains on the SF-36. Donors whose recipients had no complications scored significantly higher in mental health (P<0.007) and general health (P<0.008) compared with U.S. norms. Donors whose recipients had major complications scored significantly lower on the mental health scale than those with recipients without major complications. CONCLUSIONS: Donors did not regret their decision to donate; several felt the experience had changed their lives for the better. Donors scored as well as or better than U.S. norms in general health. Quality of life after donation must remain a primary outcome measure when we consider the utility of living-donor liver transplants.


Assuntos
Hepatectomia/reabilitação , Transplante de Fígado , Doadores Vivos/psicologia , Adulto , Escolaridade , Feminino , Nível de Saúde , Inquéritos Epidemiológicos , Hepatectomia/psicologia , Humanos , Relações Interpessoais , Masculino , Saúde Mental , Grupos Raciais , Valores de Referência , Fatores de Tempo , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA