Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Aging Clin Exp Res ; 29(6): 1113-1120, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28155182

RESUMO

Montreal cognitive assessment (MoCA) is a test providing a brief screening for people with cognitive impairment due to aging or neurodegenerative syndromes. In Italy, as in the rest of the world, several validation studies of MoCA have been carried out. This study compared, for the first time in Italy, a sample of people with probable Alzheimer's Disease (AD) with healthy counterparts. The study also compared two community-dwelling groups of aged participants with and without probable cognitive impairment, as discriminated by two cut-off points of adjusted MMSE score. All the comparisons were carried out according to ROC statistics. Optimal cutoff for a diagnosis of probable AD was a MoCA score ≤14. Optimal cutoff for the discrimination of probable cognitive impairment was a MoCA score ≤17 (associated to MMSE cutoff of 23.8). Results confirm the substantial discrepancy in cut-off points existing between Italian and other international validation studies, showing that Italian performance on MoCA seems to be globally lower than that in other Countries. Characteristics of population might explain these results.


Assuntos
Doença de Alzheimer/diagnóstico , Disfunção Cognitiva/diagnóstico , Testes de Estado Mental e Demência/normas , Idoso , Idoso de 80 Anos ou mais , Meio Ambiente , Feminino , Humanos , Vida Independente , Itália , Masculino , Testes Neuropsicológicos , Probabilidade
2.
J Heart Valve Dis ; 17(3): 276-82, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18592924

RESUMO

BACKGROUND AND AIM OF THE STUDY: Percutaneous catheter-based mitral annuloplasty (PTMA) exploits the anatomic proximity of the coronary sinus (CS) to the mitral valve apparatus. Acute results of PTMA have been favorable, but the durability of the geometric alterations associated with PTMA has not been reported. The study aim was to assess the three-dimensional (3D) geometry of the mitral annulus (MA) in normal sheep at 20 weeks after PTMA implantation. METHODS: A PTMA device was implanted percutaneously in the CS of 10 normal sheep without mitral regurgitation. All animals were followed for 20 weeks with real-time 3D echocardiography (RT3DE). The MA area, the diagonal diameters in four directions, and the angle alpha, representing the degree of the saddle shape of MA, were determined. RESULTS: No significant hemodynamic, pathologic or mechanical complications were observed during implantation or follow up. Both, the MA area (from 4.8 +/- 0.9 cm2 to 3.7 +/- 0.9 cm2) and anterior-posterior (A-P) diameter (from 21.4 +/- 3.0 mm to 17.6 +/- 2.4 mm) were reduced immediately after the procedure (both p <0.05). The angle alpha decreased after the procedure (from 142.0 +/- 11.5 degrees to 128.3 +/- 15.6 degrees; p <0.05). These changes remained stable over the 20-week follow up period. CONCLUSION: RT3DE demonstrates that PTMA reduces the MA area and A-P diameter and maintains the physiologic curved or saddle shape of the MA. These changes remained stable for 20 weeks after device implantation.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Animais , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardiovasculares/instrumentação , Procedimentos Cirúrgicos Cardiovasculares/métodos , Simulação por Computador , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral/cirurgia , Modelos Animais , Modelos Cardiovasculares , Ovinos
3.
J Am Soc Echocardiogr ; 17(5): 411-7, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15122179

RESUMO

We assessed the effects of implantation of Myosplint (Myocor, Maple Grove, Minn), a device that changes left ventricular (LV) cross-sectional shape from circular to bilobar, on regional LV function. A total of 10 open-chest dogs with tachycardia-induced cardiomyopathy were studied before and after Myosplint implantation. LV cross-sectional epicardial echocardiography at the papillary muscle level was performed along with acquisition of hemodynamic data. LV normalized thickening, fractional thickening, end-diastolic thickness, and end-diastolic curvatures were calculated for 10 LV segments. Myosplint implantation did not affect LV hemodynamics, but decreased average end-diastolic curvature (P <.0001) and increased its segmental heterogeneity (P <.0001). There was no change in average fractional thickening, whereas normalized thickening increased (P =.05). In contrast, segmental heterogeneity of both normalized and fractional thickening increased (P =.02 and P =.01, respectively). Structural modeling confirmed that Myosplint implantation increases regional stress heterogeneity and curvature heterogeneity. LV cross-sectional shape markedly affects regional LV performance.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Coração Auxiliar , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Cardiomiopatias/patologia , Cães , Modelos Cardiovasculares , Ultrassonografia , Disfunção Ventricular Esquerda/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA