Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Appl Physiol ; 122(4): 945-954, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35059801

RESUMO

PURPOSE: The aim of the present investigation is to study the relationship of ventricular global longitudinal strain (GLS) and ultrasound lung comets (ULC) formation to establish a link between extravascular pulmonary water formation and cardiac contractile dysfunction. METHODS: This is a prospective observational study including 14 active military divers. The subjects performed two sea dives of 120 min each with a semi-closed SCUBA circuit at 10 m depth. Divers were examined at baseline, 15 min (D1) and 60 min (D2) after diving. The evaluation included pulmonary and cardiac echography (including speckle tracking techniques). Blood samples were drawn at baseline and after diving, assessing hs-TnT and Endothelin-1. RESULTS: ULC were detected in 9 (64.2%) and 8 (57.1%) of the subjects after D1 and D2 respectively. No differences were found in right and left ventricular GLS after both immersions (RV: Baseline: - 17.9 4.9 vs. D1: - 17.2 6.5 and D2: - 16.7 5.8 s-1; p = 0.757 and p = 0.529; LV: Baseline: - 17.0 2.3 vs. D1: - 17.4 2.1 and D2: - 16.9 2.2 s-1; p = 0.546 and p = 0.783). However, a decrease in atrial longitudinal strain parameters have been detected after diving (RA: Baseline: 35.5 9.2 vs. D1: 30.3 12.8 and D2: 30.7 13.0 s-1; p = 0.088 and p = 0.063; LA: Baseline: 39.0 10.0 vs. D1: 31.6 6.1 and D2: 32.4 10.6 s-1; p = 0.019 and p = 0.054). CONCLUSION: In the present study, no ventricular contractile dysfunction was observed. However, increase pulmonary vasoconstriction markers were present after diving.


Assuntos
Mergulho , Água Extravascular Pulmonar , Ecocardiografia , Água Extravascular Pulmonar/diagnóstico por imagem , Humanos , Contração Miocárdica , Ultrassonografia
2.
Eur J Echocardiogr ; 11(1): 9-13, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19805413

RESUMO

AIMS: To determine the feasibility of real-time three-dimensional transoesophageal echocardiography (3D-TOE) in the evaluation of aortic valve stenosis, to study its reliability, and to test the concordance of this new method when compared with transthoracic two-dimensional echocardiography (2D-TTE) as the diagnostic standard. METHODS AND RESULTS: Fifty-nine consecutive patients with moderate-to-severe aortic valve stenosis were assessed by means of 2D-TTE and 3D-TOE by independent blinded observers. Aortic valve planimetry was possible in 94.9% of patients. Inter-observer intraclass correlation coefficients (ICC) were 0.892 (CI 95% 0.818-0.936; P < 0.001), and 0.871 (CI 95% 0.780-0.925; P < 0.001) for 2D-TTE and 3D-TOE, respectively. Bland-Altman plot showed a mean difference in aortic valve area (AVA) of 0.040 cm(2), with 2D-TTE yielding larger values than 3D-TOE. ICC of both methods was 0.724 (CI 95% 0.530-0.839; P < 0.001). CONCLUSION: Assessment of AVA by means of 3D-TOE is feasible in most patients with aortic valve stenosis. Reliability of the measurement is good. However, there is some disagreement with standard 2D-TTE that needs further investigation.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Intervalos de Confiança , Estudos de Viabilidade , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA