1.
Invest Radiol ; 52(2): 81-86, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27518213

RESUMO

INTRODUCTION: Recent studies have shown a substantial reduction of radiation dose from computed tomography (CT) scans down to 0.1 mSv for lung cancer screening and cardiac examinations, when applying optimization techniques. Hence, CT localizer radiographs (LRs) might now be considered a significant contributor to the total dose of the CT examination. We investigated in our study the potential for reducing dose of the LRs by adapting the patient-specific acquisition parameters of the LR. MATERIALS AND METHODS: Localizer radiographs covering the lungs were acquired on 2 clinical scanners (64 slices, conventional detector [CD]; 96 slices, fully integrated detector [ID]) for 3 semianthropomorphic phantoms, representing a slim, a normal, and an obese adult. Starting at 120-kV tube voltage and 250-mA current were reduced until the image quality of the LR, and thereby the accuracy of the automatic exposure control was compromised; this was defined as a deviation of measured attenuation values in the center of the LR of more than 5% from the reference values measured at the highest tube voltage and current. Subsequent Monte Carlo calculations on anthropomorphic phantoms were performed to calculate organ and effective dose values for the respective optimal settings. In addition, effective dose values normalized to CTDIvol for tube voltages ranging from 60 to 160 kV were determined for the different combinations of phantom sizes, sexes, and LR views to evaluate dose efficiency. RESULTS: For the CD scanner, the optimal LR settings depended strongly on phantom size. Higher tube voltage and current were necessary for the larger phantoms. The ID scanner showed uncompromised LR quality for all phantoms using the lowest possible tube voltage-tube current combination of 80 kV and 20 mA. Depending on patient size and LR direction, effective dose values for the optimal settings ranged from 6 to 53 µSv and 3 to 11 µSv for the CD and ID scanner, respectively. For the example of an anterior-posterior LR on a normal patient, using the optimal settings instead of the standard settings on the ID scanner reduced LR dose from 53 µSv (120 kV, 30 mA) to 10 µSv (80 kV, 20 mA). The simulations for the different tube voltages show that effective dose and CTDIvol behave similarly for different views and patient sizes. However, the tube voltage level itself impacts the relationship between CTDIvol and effective dose, by up to a factor of 2. DISCUSSION: Dose from LRs may contribute significantly to the total effective dose of low-dose CT examinations such as lung cancer screening. Optimal LR settings can reduce LR dose substantially, but adaptations have to consider scanner characteristics, detector technology, and patient size. Thus, for low-dose CT examinations, such as cardiac examinations and lung cancer screening, LR optimization may result in a significant dose reduction and thereby in a substantial reduction of total dose.


Assuntos
Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Humanos , Método de Monte Carlo
2.
Invest Radiol ; 50(2): 114-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25373305

RESUMO

INTRODUCTION: One method to acquire dual-energy (DE) computed tomography (CT) data is to perform CT scans at 2 different x-ray tube voltages, typically 80 and 140 kV, either as 2 separate scans, by means of rapid kV switching, or with the use of 2 x-ray sources as in dual-source CT (DSCT) systems. In DSCT, it is possible to improve spectral separation with tin prefiltration (Sn) of the high-kV beam. Recently, x-ray tube voltages beyond the established range of 80 to 140 kV were commercially introduced, which enable additional voltage combinations for DE acquisitions, such as 80/150 Sn or 90/150 Sn kV. Here, we investigate the DE performance of several x-ray tube voltages and prefilter combinations on 2 DSCT scanners and the impact of the spectra on quantitative analysis and dose efficiency. MATERIALS AND METHODS: Circular phantoms of different sizes (10-40 cm in diameter) equipped with cylindrical inserts containing water and diluted iodine contrast agent (14.5 mg/cm) were scanned using 2 different DSCT systems (SOMATOM Definition Flash and SOMATOM Force; Siemens AG, Forchheim, Germany). Five x-ray tube voltage combinations (80/140 Sn, 100/140 Sn, 80/150 Sn, 90/150 Sn, and 100/150 Sn kV) were investigated, and the results were compared with the previous standard acquisition technique (80/140 kV). As an example, 80/140 Sn kV means that 1 x-ray tube of the DSCT system was operated at 80 kV, whereas the other was operated at 140 kV with additional tin prefiltration (Sn). Dose values in terms of computed tomography dose index (CTDIvol) were kept constant between the different voltage combinations but adjusted with regard to object size according to automatic exposure control recommendations. Reconstructed images were processed using linear blending of the low- and high-kV CT images to combined images, as well as 3-material decomposition techniques to generate virtual noncontrast (VNC) images and iodine images. Contrast and pixel noise were evaluated, as well as DE ratios, which are defined as the CT value at low kV divided by the CT value at high kV. RESULTS: For the 10-, 20-, 30-, and 40-cm phantom, dose values in terms of CTDIvol were 1.2, 2.6, 7.3, and 21.6 mGy, respectively. In the combined images, those obtained with tin filtration showed lower noise values at similar iodine enhancement levels than did images obtained without tin filtration. The largest differences in noise were observed for the larger phantoms, in particular the 40-cm phantom. Dual-energy ratios for iodine increased with decreasing voltages of the low-kV beam and with increasing voltages of the high-kV beam, and they increased when tin prefiltration was added. In case of the 20-cm phantom, DE ratios ranged from 2.0 at 80/140 kV to 3.4 at 80/150 Sn kV. The noise level of the VNC images was strongly correlated with the inverse of the DE ratio. Irrespective of the phantom size, the lowest noise values were measured for 80/150 Sn kV. DISCUSSION: Dual-source CT systems enable DE data to be acquired using a variety of voltage combinations. Combined (or mixed) DE images provide an image impression similar to standard 120 kV images, yet the noise level depends on the DE voltage combination that is selected. Noise in decomposed VNC images is strongly influenced by the DE ratio, and it improves substantially with tin filtration of the high-voltage beam.


Assuntos
Doses de Radiação , Proteção Radiológica/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade