Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
BJR Open ; 6(1): tzae006, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38737623

RESUMO

Objectives: We validated an auto-contouring algorithm for heart substructures in lung cancer patients, aiming to establish its accuracy and reliability for radiotherapy (RT) planning. We focus on contouring an amalgamated set of subregions in the base of the heart considered to be a new organ at risk, the cardiac avoidance area (CAA), to enable maximum dose limit implementation in lung RT planning. Methods: The study validates a deep-learning model specifically adapted for auto-contouring the CAA (which includes the right atrium, aortic valve root, and proximal segments of the left and right coronary arteries). Geometric, dosimetric, quantitative, and qualitative validation measures are reported. Comparison with manual contours, including assessment of interobserver variability, and robustness testing over 198 cases are also conducted. Results: Geometric validation shows that auto-contouring performance lies within the expected range of manual observer variability despite being slightly poorer than the average of manual observers (mean surface distance for CAA of 1.6 vs 1.2 mm, dice similarity coefficient of 0.86 vs 0.88). Dosimetric validation demonstrates consistency between plans optimized using auto-contours and manual contours. Robustness testing confirms acceptable contours in all cases, with 80% rated as "Good" and the remaining 20% as "Useful." Conclusions: The auto-contouring algorithm for heart substructures in lung cancer patients demonstrates acceptable and comparable performance to human observers. Advances in knowledge: Accurate and reliable auto-contouring results for the CAA facilitate the implementation of a maximum dose limit to this region in lung RT planning, which has now been introduced in the routine setting at our institution.

2.
Int J Cardiovasc Imaging ; 40(3): 557-567, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38064141

RESUMO

Cardiac magnetic resonance (CMR) can provide a multi-parametric evaluation of left atrial (LA) size and function. A complete CMR-based LA assessment might improve the risk stratification of patients with non-ischemic dilated cardiomyopathy (DCM). We performed a comprehensive CMR-based evaluation of LA size and function, in order to assess the prognostic impact of specific LA parameters in DCM. Secondary analysis of a prospective registry (UHSM-CMR study, NCT02326324) including 648 consecutive patients with DCM and CMR evaluation of LA area and LA length. Of these, 456 had complete LA assessment covering reservoir, conduit and booster pump function and including LA reservoir strain evaluated with feature tracking. The heart failure (HF) endpoint included HF hospitalizations, HF death and heart transplant. The arrhythmic endpoint included ventricular arrhythmias (VA) (sustained or treated by implantable defibrillator) and sudden death (SD). At median follow-up of 23 months, 34 patients reached the HF endpoint; in a multivariable model including NYHA class and LVEF, LA length had incremental predictive value. LA length ≥ 69 mm was the best cut-off to predict HF events (adjusted HR 2.3, p = 0.03). Among the 456 patients with comprehensive LA assessment, only LA length was independently associated with the HF endpoint after adjusting for LVEF and NYHA class. By contrast, no LA parameter independently predicted the arrhythmic risk. In DCM patients, LA length is an independent predictor of HF events, showing stronger association than other more complex parameters of LA function. No atrial parameter predicts the risk of VA and SD.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Humanos , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Arritmias Cardíacas , Espectroscopia de Ressonância Magnética , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia
3.
Nucl Med Commun ; 38(1): 44-50, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27898646

RESUMO

BACKGROUND: Global iodine-123 metaiodobenzylguanidine (I-MIBG) uptake is predictive of cardiovascular events and mortality in patients with heart failure. Normal variations in global and regional uptake, however, are not well defined and few studies have addressed the functional relevance of I-MIBG uptake and distribution in healthy individuals. MATERIALS AND METHODS: We performed I-MIBG scintigraphy and cardiac autonomic function testing using the standardized methodology in 15 healthy individuals (mean age 54.6±5.3 years, male : female 10 : 5) with no evidence of previous myocardial infarction or ischaemic heart disease. RESULTS: Early heart to mediastinum ratio (HMR) was 1.67±0.13, late HMR was 1.73±0.16 and washout rate was 19.09±7.63% (4.20-31.30). Regional analysis showed reduced tracer uptake at the apex, base and inferior wall in all individuals. Early and late HMR correlated negatively with RFa (r=-0.603; P=0.05 and r=-0.644; P=0.033) and expiration and inspiration ratio (r=-0.616; P=0.043 and r=-0.676; P=0.022) and positively with LFa/RFa (r=0.711; P=0.014 and r=0.784; P=0.004). Washout rate correlated only with RFa (r=0.642; P=0.033). CONCLUSION: Healthy adults show a heterogeneous pattern of cardiac innervation with reduced regional uptake of I-MIBG. Furthermore, HMR correlates with indices of cardiac sympathetic function, suggesting that it might not only be a useful prognostic marker but may also provide insight into the functional integrity of the cardiac autonomic nervous system.


Assuntos
3-Iodobenzilguanidina , Sistema Nervoso Autônomo/diagnóstico por imagem , Coração/diagnóstico por imagem , Coração/inervação , Radioisótopos do Iodo , Sistema Nervoso Simpático/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Sistema Nervoso Autônomo/fisiologia , Feminino , Voluntários Saudáveis , Coração/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Valores de Referência , Sistema Nervoso Simpático/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
4.
J Magn Reson Imaging ; 40(1): 133-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24923478

RESUMO

PURPOSE: To evaluate the use of right ventricular (RV) annulo-apical angle (AA) changes acquired by magnetic resonance imaging (MRI), alongside tricuspid annular plane systolic excursion (TAPSE), for its association with RV systolic function. MATERIALS AND METHODS: Thirty patients with varying RV dysfunction and 10 normal controls were enrolled and scanned after obtaining written consent. Systolic change in AAs, alpha (α), beta (ß), and theta (θ), subtended by a triangle connecting the septal and lateral extent of the tricuspid valve annulus and RV apex, and TAPSE were measured. Spearman rank correlations of parameters with RV ejection fraction (RVEF) were performed. Receiver operating characteristic (ROC) analysis was used to determine accuracy of these surrogate markers for detecting abnormal RVEF. RESULTS: Correlations with RVEF included: TAPSE (r = 0.74 P < 0.001), fractional systolic changes in α angle (0.64, P < 0.001), ß angle (-0.39, P < 0.05), and θ angle (-0.77, P < 0.001). The best markers for RVEF <50% were fractional θ angle change ≥ -25.5% (eg, -24%) (sensitivity of 97% and specificity of 91%), and TAPSE ≤1.87 cm (sensitivity of 100% and specificity of 82%). Intra- and inter-observer agreement was excellent, with intraclass correlation coefficients for fractional θ angle change (intra = 0.96, inter = 0.94) and TAPSE (intra = 0.98, inter = 0.87). CONCLUSION: Fractional θ angle change is a useful semiquantitative parameter associated with the presence and severity of RV systolic dysfunction, with high observer agreement.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico , Adulto , Idoso , Feminino , Ventrículos do Coração , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Am Coll Cardiol ; 63(8): 799-808, 2014 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-24355800

RESUMO

OBJECTIVES: This study sought to evaluate the diagnostic performance of multiparametric cardiovascular magnetic resonance (CMR) for detecting cardiac allograft vasculopathy (CAV) using contemporary invasive epicardial artery and microvascular assessment techniques as reference standards, and to compare the performance of CMR with that of angiography. BACKGROUND: CAV continues to limit the long-term survival of heart transplant recipients. Coronary angiography has a Class I recommendation for CAV surveillance and annual or biannual surveillance angiography is performed routinely in most centers. METHODS: All transplant recipients referred for surveillance angiography at a single UK center over a 2-year period were prospectively screened for study eligibility. Patients prospectively underwent coronary angiography followed by coronary intravascular ultrasound, fractional flow reserve, and index of microcirculatory resistance. Within 1 month, patients underwent multiparametric CMR, including assessment of regional and global ventricular function, absolute myocardial blood flow quantification, and myocardial tissue characterization. In addition, 10 healthy volunteers underwent CMR. RESULTS: Forty-eight patients were recruited, median 7.1 years (interquartile range: 4.6 to 10.3 years) since transplantation. The CMR myocardial perfusion reserve was the only independent predictor of both epicardial (ß = -0.57, p < 0.001) and microvascular disease (ß = -0.60, p < 0.001) on stepwise multivariable regression. The CMR myocardial perfusion reserve significantly outperformed angiography for detecting moderate CAV (area under the curve, 0.89 [95% confidence interval (CI): 0.79 to 1.00] vs. 0.59 [95% CI: 0.42 to 0.77], p = 0.01) and severe CAV (area under the curve, 0.88 [95% CI: 0.78 to 0.98] vs. 0.67 [95% CI: 0.52 to 0.82], p = 0.05). CONCLUSIONS: CAV, including epicardial and microvascular components, can be detected more accurately using noninvasive CMR-based absolute myocardial blood flow assessment than with invasive coronary angiography, the current clinical surveillance technique.


Assuntos
Aloenxertos/patologia , Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Transplante de Coração/efeitos adversos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Aloenxertos/fisiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Feminino , Transplante de Coração/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Circ Cardiovasc Imaging ; 6(3): 373-83, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23553570

RESUMO

BACKGROUND: Extracellular matrix expansion is a key element of ventricular remodeling and a potential therapeutic target. Cardiovascular magnetic resonance (CMR) T1-mapping techniques are increasingly used to evaluate myocardial extracellular volume (ECV); however, the most widely applied methods are without histological validation. Our aim was to perform comprehensive validation of (1) dynamic-equilibrium CMR (DynEq-CMR), where ECV is quantified using hematocrit-adjusted myocardial and blood T1 values measured before and after gadolinium bolus; and (2) isolated measurement of myocardial T1, used as an ECV surrogate. METHODS AND RESULTS: Whole-heart histological validation was performed using 96 tissue samples, analyzed for picrosirius red collagen volume fraction, obtained from each of 16 segments of the explanted hearts of 6 patients undergoing heart transplantation who had prospectively undergone CMR before transplantation (median interval between CMR and transplantation, 29 days). DynEq-CMR-derived ECV was calculated from T1 measurements made using a modified Look-Locker inversion recovery sequence before and 10 and 15 minutes post contrast. In addition, ECV was measured 2 to 20 minutes post contrast in 30 healthy volunteers. There was a strong linear relationship between DynEq-CMR-derived ECV and histological collagen volume fraction (P<0.001; within-subject: r=0.745; P<0.001; r(2)=0.555 and between-subject: r=0.945; P<0.01; r(2)=0.893; for ECV calculated using 15-minute postcontrast T1). Correlation was maintained throughout the entire heart. Isolated postcontrast T1 measurement showed significant within-subject correlation with histological collagen volume fraction (r=-0.741; P<0.001; r(2)=0.550 for 15-minute postcontrast T1), but between-subject correlations were not significant. DynEq-CMR-derived ECV varied significantly according to contrast dose, myocardial region, and sex. CONCLUSIONS: DynEq-CMR-derived ECV shows a good correlation with histological collagen volume fraction throughout the whole heart. Isolated postcontrast T1 measurement is insufficient for ECV assessment.


Assuntos
Matriz Extracelular/patologia , Cardiopatias/diagnóstico , Imageamento por Ressonância Magnética , Miocárdio/patologia , Remodelação Ventricular , Adulto , Idoso , Análise de Variância , Compostos Azo , Biomarcadores/metabolismo , Colágeno/metabolismo , Corantes , Meios de Contraste , Matriz Extracelular/metabolismo , Feminino , Fibrose , Gadolínio DTPA , Cardiopatias/sangue , Cardiopatias/metabolismo , Cardiopatias/patologia , Cardiopatias/cirurgia , Transplante de Coração , Hematócrito , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Coloração e Rotulagem/métodos , Adulto Jovem
8.
J Magn Reson Imaging ; 38(2): 320-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23239005

RESUMO

PURPOSE: To compare local sine-wave modeling (SinMod) with harmonic phase analysis (HARP), for assessment of left ventricular (LV) circumferential strain (εcc) from tagged cardiovascular magnetic resonance images. MATERIALS AND METHODS: Mid-ventricular spatial modulation of magnetization was performed in 60 participants (15 each with hypertrophic, dilated or ischemic cardiomyopathy and 15 healthy controls) at 1.5 Tesla. Global and segmental peak transmural εcc were measured using HARP and SinMod. Repeated measurements were performed on 25% of examinations to assess observer variability. Effect of contrast was assessed in 10 additional patients. RESULTS: SinMod showed a high level of agreement with HARP for global εcc (mean difference -0.02, 95% limits of agreement -6.46 to 6.43%). Agreement was much lower for segmental εcc. Both methods showed excellent observer agreement for global εcc (intraclass correlation coefficient >0.75). Observer agreement for segmental εcc was also excellent with SinMod, but was significantly lower with HARP. Analysis time was significantly shorter using SinMod. Pre- and postcontrast εcc measurements were not significantly different using either technique, although postcontrast measurements showed greater variability with HARP. CONCLUSION: SinMod and HARP-based measurements of global εcc have a high level of agreement, but segmental agreement is substantially lower. SinMod has generally lower observer variability, is faster and is less affected by contrast, but requires further validation.


Assuntos
Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Cardiovasculares , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia , Cardiomiopatias/complicações , Simulação por Computador , Módulo de Elasticidade , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
10.
Eur Heart J Cardiovasc Imaging ; 13(2): 187-95, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22109245

RESUMO

AIMS: To compare left ventricular (LV) volume indices and the ejection fraction (EF) obtained using real-time three-dimensional echocardiography (RT3DE) and cardiovascular magnetic resonance (CMR) in unselected patients representative of 'real-world' clinical practice, and to determine the effect of RT3DE image quality on these parameters. METHODS AND RESULTS: Sixty consecutive patients undergoing CMR underwent same day RT3DE. LV volume and EF measurements were made using both modalities and compared. All scans were independently analysed by a second observer to assess inter-observer variability, and 40% were re-analysed to assess intra-observer variability. RT3DE image quality was graded as good, adequate, and non-analysable. Thirteen (22%) patients had good RT3DE image quality, 29 (48%) had adequate image quality, and 18 (30%) had image quality precluding analysis. Body mass index and arrhythmia frequency were higher in patients with suboptimal image quality. RT3DE significantly underestimated end-diastolic volume (EDV) (-45 ± 35 mL, P < 0.001), end-systolic volume (ESV) (-11 ± 24 mL, P = 0.004), and EF (-7 ± 9%, P < 0.001) compared with CMR although the degree of underestimation was substantially less when image quality was good. Eleven patients (18%) classified as having a normal EF by CMR had a reduced EF according to RT3DE, all but one of which had suboptimal image quality. Observer variability for RT3DE was higher than for CMR for all parameters, however, the difference was not significant when RT3DE image quality was good. CONCLUSIONS: In contrast to previously published data from highly selected patient groups, 'real-world' RT3DE substantially underestimates LV volumes and EF. The degree of underestimation is related to image quality.


Assuntos
Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética , Volume Sistólico , Idoso , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA