1.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872126

RESUMO

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Assuntos
Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Osso Temporal , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem , Idoso , Adulto , Implante Coclear/métodos
2.
Acad Radiol ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38519304

RESUMO

RATIONALE AND OBJECTIVES: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration. PATIENTS AND METHODS: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality. RESULTS: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0-93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC=0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4). CONCLUSION: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.

3.
Eur Radiol ; 32(1): 234-242, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34226991

RESUMO

OBJECTIVES: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. METHODS: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. RESULTS: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients' age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. CONCLUSION: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors. KEY POINTS: • Post-operative radiological assessment of the mastoid facial canal and the positional relationship with the CI electrode provide no predictor of post-cochlear implant facial nerve stimulation. • Radiological detection of extracochlear electrode contacts and the previous clinical history of meningitis/encephalitis are two important risk factors for postoperative facial nerve stimulation in cochlear implant patients. • The presence of scala vestibuli electrode insertion as well as the lateral wall electrode type, the younger patient's age, and early onset of SNHL can play important role in the prediction of post-cochlear implant facial nerve stimulation.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Idoso , Criança , Cóclea , Nervo Facial/diagnóstico por imagem , Humanos , Processo Mastoide/diagnóstico por imagem , Processo Mastoide/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
J Comput Assist Tomogr ; 40(1): 80-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466115

RESUMO

OBJECTIVE: The aim of the study was to evaluate objective and subjective image qualities of virtual monoenergetic imaging (VMI) in dual-source dual-energy computed tomography (DECT) and optimal kiloelectron-volt (keV) levels for lung cancer. METHODS: Fifty-nine lung cancer patients underwent chest DECT. Images were reconstructed as VMI series at energy levels of 40, 60, 80, and 100 keV and standard linear blending (M_0.3) for comparison. Objective and subjective image qualities were assessed. RESULTS: Lesion contrast peaked in 40-keV VMI reconstructions (2.5 ± 2.9) and 60 keV (1.9 ± 3.0), which was superior to M_0.3 (0.5 ± 2.7) for both comparisons (P < 0.001). Compared with M_0.3, subjective ratings were highest for 60-keV VMI series regarding general image quality (4.48 vs 4.52; P = 0.74) and increased for lesion demarcation (4.07 vs 4.84; P < 0.001), superior to all other VMI series (P < 0.001). Image sharpness was similar between both series. Image noise was rated superior in the 80-keV and M_0.3 series, followed by 60 keV. CONCLUSIONS: Virtual monoenergetic imaging reconstructions at 60-keV provided the best combination of subjective and objective image qualities in DECT of lung cancer.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
6.
Eur Radiol ; 25(8): 2493-501, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25680727

RESUMO

OBJECTIVES: To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). METHODS: DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. RESULTS: The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056). CONCLUSIONS: Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. KEY POINTS: • Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS