Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
PLoS One ; 17(7): e0269592, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35802680

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with extracellular matrix (ECM) remodelling and often coexists with myocardial fibrosis (MF); however, the causality of these conditions is not well established. OBJECTIVE: We aim to corroborate AF to MF causality by quantifying left atrial (LA) fibrosis in cardiac magnetic resonance (CMR) images after persistent rapid ventricular pacing and subsequent AF using a canine model and histopathological validation. METHODS: Twelve canines (9 experimental, 3 control) underwent baseline 3D LGE-CMR imaging at 3T followed by insertion of a pacing device and 5 weeks of rapid ventricular pacing to induce AF (experimental) or no pacing (control). Following the 5 weeks, pacing devices were removed to permit CMR imaging followed by excision of the hearts and histopathological imaging. LA myocardial segmentation was performed manually at baseline and post-pacing to permit volumetric %MF quantification using the image intensity ratio (IIR) technique, wherein fibrosis was defined as pixels > mean LA myocardium intensity + 2SD. RESULTS: Volumetric %MF increased by an average of 2.11 ± 0.88% post-pacing in 7 of 9 experimental dogs. While there was a significant difference between paired %MF measurements from baseline to post-pacing in experimental dogs (P = 0.019), there was no significant change in control dogs (P = 0.019 and P = 0.5, Wilcoxon signed rank tests). The median %MF for paced animals was significantly greater than that of non-paced dogs at the 5-week post-insertion time point (P = 0.009, Mann Whitney U test). Histopathological imaging yielded an average %MF of 19.42 ± 4.80% (mean ± SD) for paced dogs compared to 1.85% in one control dog. CONCLUSION: Persistent rapid ventricular pacing and subsequent AF leads to an increase in LA fibrosis volumes measured by the IIR technique; however, quantification is limited by inherent image acquisition parameters and observer variability.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Animais , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Fibrilação Atrial/terapia , Cardiomiopatias/patologia , Meios de Contraste , Cães , Fibrose , Gadolínio , Átrios do Coração , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA