Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Radiol Prot ; 44(2)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38838649

RESUMO

Protection against ionizing radiations is important in laboratories with radioactive materials and high energy cyclotron beams. The Cyclotron and Radioisotope Center (CYRIC) located in Tohoku University in Miyagi prefecture, Japan and is a well-known nuclear science laboratory with cyclotron beams and substantial number of high activity radioactive materials. Considering this, it is important to perform complete radiation transport computations to ensure the safety of non-occupational and occupational workers. In the present work, we have developed a complete 3-dimensional model of the main cyclotron building and radiation labs using Monte Carlo method. We have found that the dispersed photons and neutrons inside and in the surrounding of the CYRIC building pose no significant risk to occupational and non-occupational workers. The present work and the developed models would be useful in the field of radiation protection.


Assuntos
Ciclotrons , Método de Monte Carlo , Proteção Radiológica , Japão , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Doses de Radiação , Simulação por Computador , Humanos , Universidades
2.
Radiat Prot Dosimetry ; 200(2): 130-142, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37961917

RESUMO

Previously, we have developed DynamicMC for modeling relative movement of Oak Ridge National Laboratory phantom in a radiation field for the Monte Carlo N-Particle package (Health Physics. 2023,124(4):301-309). Using this software, three-dimensional dose distributions in a phantom irradiated by a certain mono-energetic (Mono E) source can be deduced through its graphical user interface. In this study, we extended DynamicMC to be used in combination with the Particle and Heavy Ion Transport code System (PHITS) by providing it with a higher flexibility for dynamic movement for an anthropomorphic phantom. For this purpose, we implemented four new functions into the software, which are (1) to generate not only Mono E sources but also those having an energy spectrum of an arbitrary radioisotope (2) to calculate the absorbed doses for several radiologically important organs (3) to automatically average the calculated absorbed doses along the path of the phantom and (4) to generate user-defined slab shielding materials. The first and third items utilize the PHITS-specific modalities named radioisotope-source and sumtally functions, respectively. The computational cost and complexity can be dramatically reduced with these features. We anticipate that the present work and the developed open-source tools will be in the interest of nuclear radiation physics community for research and teaching purposes.


Assuntos
Física Médica , Radiometria , Radiometria/métodos , Física Médica/métodos , Software , Movimento , Imagens de Fantasmas , Radioisótopos , Método de Monte Carlo
3.
Health Phys ; 124(4): 301-309, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728190

RESUMO

ABSTRACT: The present work introduces an open-source graphical user interface (GUI) computer program called DynamicMC. The present program has the ability to generate ORNL phantom input script for the Monte Carlo N-Particle (MCNP) package. The relative dynamic movement of the radiation source with respect to the ORNL phantom can be modeled, which essentially resembles the dynamic movement of source-to-target (i.e., human phantom) distance in a 3-dimensional radiation field. The present program makes the organ-based dosimetry of the human body much easier, as users are not required to write lengthy scripts or deal with any programming that many may find tedious, time consuming, and error prone. In this paper, we have demonstrated that the present program can successfully model simple and complex relative dynamic movements (i.e., those involving rotation of source and human phantom in a 3-dimensional field). The present program would be useful for organ-based dosimetry and could also be used as a tool for teaching nuclear radiation physics and its interaction with the human body.


Assuntos
Radiometria , Software , Humanos , Radiometria/métodos , Imagens de Fantasmas , Método de Monte Carlo , Simulação por Computador
4.
Sci Rep ; 12(1): 18098, 2022 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-36302927

RESUMO

The present work introduced a framework to investigate the effectiveness of proton boron fusion therapy (PBFT) at the cellular level. The framework consisted of a cell array generator program coupled with PHITS Monte Carlo package with a dedicated terminal-based code editor that was developed in this work. The framework enabled users to model large cell arrays with normal, all boron, and random boron filled cytoplasm, to investigate the underlying mechanism of PBFT. It was found that alpha particles and neutrons could be produced in absence of boron mainly because of nuclear reaction induced by proton interaction with 16O, 12C and 14N nuclei. The effectiveness of PBFT is highly dependent on the incident proton energy, source size, cell array size, buffer medium thickness layer, concentration and distribution of boron in the cell array. To quantitatively assess the effectiveness of PBFT, of the total energy deposition by alpha particle for different cases were determined. The number of alpha particle hits in cell cytoplasm and nucleus for normal and 100 ppm boron were determined. The obtained results and the developed tools would be useful for future development of PBFT to objectively determine the effectiveness of this treatment modality.


Assuntos
Terapia por Captura de Nêutron de Boro , Terapia com Prótons , Boro , Terapia por Captura de Nêutron de Boro/métodos , Prótons , Nêutrons , Método de Monte Carlo
5.
Tomography ; 8(5): 2313-2329, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-36136889

RESUMO

Proton irradiations are highly sensitive to spatial variations, mainly due to their high linear energy transfer (LET) and densely ionizing nature. In realistic clinical applications, the targets of ionizing radiation are inhomogeneous in terms of geometry and chemical composition (i.e., organs in the human body). One of the main methods for proton range monitoring is to utilize the production of proton induced positron emitting radionuclides; these could be measured precisely with positron emission tomography (PET) systems. One main positron emitting radionuclide that could be used for proton range monitoring and verification was found to be 13N that produces a peak close to the Bragg peak. In the present work, we have employed the Monte Carlo method and Spectral Analysis (SA) technique to investigate the feasibility of utilizing the 13N peak for proton range monitoring and verification in inhomogeneous targets. Two different phantom types, namely, (1) ordinary slab and (2) MIRD anthropomorphic phantoms, were used. We have found that the generated 13N peak in such highly inhomogeneous targets (ordinary slab and human phantom) is close to the actual Bragg peak, when irradiated by incident proton beam. The feasibility of using the SA technique to estimate the distribution of positron emitter was also investigated. The current findings and the developed tools in the present work would be helpful in proton range monitoring and verification in realistic clinical radiation therapy using proton beams.


Assuntos
Terapia com Prótons , Prótons , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons/métodos , Terapia com Prótons/métodos
6.
J Radiat Res ; 63(3): 385-392, 2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35349714

RESUMO

The Monte Carlo (MC) method is a powerful tool for modeling nuclear radiation interaction with matter. A variety of MC software packages has been developed, especially for applications in radiation therapy. Most widely used MC packages require users to write their own input scripts for their systems, which can be a time consuming and error prone process and requires extensive user experience. In the present work, we have developed a graphical user interface (GUI) bundled with a custom-made 3D OpenGL visualizer for PHITS MC package. The current version focuses on modeling proton induced positron emitting radioisotopes, which in turn can be used for verification of proton ranges in proton therapy. The developed GUI program does not require extensive user experience. The present open-source program is distributed under GPLv3 license that allows users to freely download, modify, recompile and redistribute the program.


Assuntos
Terapia com Prótons , Elétrons , Método de Monte Carlo , Prótons , Radioisótopos , Software
7.
PLoS One ; 17(2): e0263521, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35167589

RESUMO

The Monte Carlo method is employed in this study to simulate the proton irradiation of a water-gel phantom. Positron-emitting radionuclides such as 11C, 15O, and 13N are scored using the Particle and Heavy Ion Transport Code System Monte Carlo code package. Previously, it was reported that as a result of 16O(p,2p2n)13N nuclear reaction, whose threshold energy is relatively low (5.660 MeV), a 13N peak is formed near the actual Bragg peak. Considering the generated 13N peak, we obtain offset distance values between the 13N peak and the actual Bragg peak for various incident proton energies ranging from 45 to 250 MeV, with an energy interval of 5 MeV. The offset distances fluctuate between 1.0 and 2.0 mm. For example, the offset distances between the 13N peak and the Bragg peak are 2.0, 2.0, and 1.0 mm for incident proton energies of 80, 160, and 240 MeV, respectively. These slight fluctuations for different incident proton energies are due to the relatively stable energy-dependent cross-section data for the 16O(p,2p2n)13N nuclear reaction. Hence, we develop an open-source computer program that performs linear and non-linear interpolations of offset distance data against the incident proton energy, which further reduces the energy interval from 5 to 0.1 MeV. In addition, we perform spectral analysis to reconstruct the 13N Bragg peak, and the results are consistent with those predicted from Monte Carlo computations. Hence, the results are used to generate three-dimensional scatter plots of the 13N radionuclide distribution in the modeled phantom. The obtained results and the developed methodologies will facilitate future investigations into proton range monitoring for therapeutic applications.


Assuntos
Radioisótopos de Nitrogênio/farmacologia , Terapia com Prótons/métodos , Algoritmos , Humanos , Método de Monte Carlo , Imagens de Fantasmas
8.
PLoS One ; 16(9): e0257638, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34534258

RESUMO

Some concepts in nuclear radiation physics are abstract and intellectually demanding. In the present paper, an "MCHP platform" (MCHP was an acronym for Monte Carlo simulations + Human Phantoms) was proposed to provide assistance to the students through visualization. The platform involved Monte Carlo simulations of interactions between ionizing radiations and the Oak Ridge National Laboratory (ORNL) adult male human phantom. As an example to demonstrate the benefits of the proposed MCHP platform, the present paper investigated the variation of the absorbed photon dose per photon from a 137Cs source in three selected organs, namely, brain, spine and thyroid of an adult male for concrete and lead shields with varying thicknesses. The results were interesting but not readily comprehensible without direct visualization. Graphical visualization snapshots as well as video clips of real time interactions between the photons and the human phantom were presented for the involved cases, and the results were explained with the help of such snapshots and video clips. It is envisaged that, if the platform is found useful and effective by the readers, the readers can also propose examples to be gradually added onto this platform in future, with the ultimate goal of enhancing students' understanding and learning the concepts in an undergraduate nuclear radiation physics course or a related course.


Assuntos
Método de Monte Carlo , Física Nuclear/educação , Proteção Radiológica/métodos , Encéfalo/efeitos da radiação , Radioisótopos de Césio/química , Corpo Humano , Humanos , Fótons , Proteção Radiológica/instrumentação , Radiação Ionizante , Radiometria , Estudantes
9.
Sci Rep ; 9(1): 11577, 2019 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-31399622

RESUMO

A calibration method was proposed in the present work to determine the medium-thickness-dependent proton doses absorbed in cellular components (i.e., cellular cytoplasm and nucleus) in radiobiological experiments. Consideration of the dependency on medium thickness was crucial as the linear energy transfer (LET) of protons could rise to a sharp peak (known as the Bragg peak) towards the end of their ranges. Relationships between the calibration coefficient R vs medium-layer thickness were obtained for incident proton energies of 10, 15, 20, 25, 30 and 35 MeV, and for various medium thicknesses up to 5000 µm, where R was defined as the ratio DA/DE, DA was the absorbed proton dose in cellular components, and DE was the absorbed proton dose in a separate radiation detector. In the present work, DA and DE were determined using the MCNPX (Monte Carlo N-Particle eXtended) code version 2.4.0. For lower incident proton energies (i.e., 10, 15 and 20 MeV), formation of Bragg-peak-like features were noticed in their R-vs-medium-layer-thickness relationships, and large R values of >7 and >6 were obtained for cytoplasm and nucleus of cells, respectively, which highlighted the importance of careful consideration of the medium thickness in radiobiological experiments.


Assuntos
Prótons , Radiometria/métodos , Animais , Calibragem , Núcleo Celular/efeitos da radiação , Citoplasma/efeitos da radiação , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Radiobiologia/métodos
10.
PLoS One ; 13(3): e0193575, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29561871

RESUMO

X-ray and γ-ray photons have been widely used for studying radiobiological effects of ionizing radiations. Photons are indirectly ionizing radiations so they need to set in motion electrons (which are a directly ionizing radiation) to perform the ionizations. When the photon dose decreases to below a certain limit, the number of electrons set in motion will become so small that not all cells in an "exposed" cell population can get at least one electron hit. When some cells in a cell population are not hit by a directly ionizing radiation (in other words not irradiated), there will be rescue effect between the irradiated cells and non-irradiated cells, and the resultant radiobiological effect observed for the "exposed" cell population will be different. In the present paper, the mechanisms underlying photon interactions in radiobiological experiments were studied using our developed NRUphoton computer code, which was benchmarked against the MCNP5 code by comparing the photon dose delivered to the cell layer underneath the water medium. The following conclusions were reached: (1) The interaction fractions decreased in the following order: 16O > 12C > 14N > 1H. Bulges in the interaction fractions (versus water medium thickness) were observed, which reflected changes in the energies of the propagating photons due to traversals of different amount of water medium as well as changes in the energy-dependent photon interaction cross-sections. (2) Photoelectric interaction and incoherent scattering dominated for lower-energy (10 keV) and high-energy (100 keV and 1 MeV) incident photons. (3) The fractions of electron ejection from different nuclei were mainly governed by the photoelectric effect cross-sections, and the fractions from the 1s subshell were the largest. (4) The penetration fractions in general decreased with increasing medium thickness, and increased with increasing incident photon energy, the latter being explained by the corresponding reduction in interaction cross-sections. (5) The areas under the angular distribution curves of photons exiting the medium layer and subsequently undergoing interactions within the cell layer became smaller for larger incident photon energies. (6) The number of cells suffering at least one electron hit increased with the administered dose. For larger incident photon energies, the numbers of cells suffering at least one electron hit became smaller, which was attributed to the reduction in the photon interaction cross-section. These results highlighted the importance of the administered dose in radiobiological experiments. In particular, the threshold administered doses at which all cells in the exposed cell array suffered at least one electron hit might provide hints on explaining the intriguing observation that radiation-induced cancers can be statistically detected only above the threshold value of ~100 mSv, and thus on reconciling controversies over the linear no-threshold model.


Assuntos
Núcleo Celular/efeitos da radiação , Método de Monte Carlo , Fótons , Radiobiologia/métodos , Algoritmos , Células Cultivadas , Simulação por Computador , Humanos , Radiometria , Espalhamento de Radiação , Água/química
11.
PLoS One ; 12(7): e0181281, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28704557

RESUMO

Monte Carlo method was used to study the characteristics of neutron interactions with cells underneath a water medium layer with varying thickness. The following results were obtained. (1) The fractions of neutron interaction with 1H, 12C, 14N and 16O nuclei in the cell layer were studied. The fraction with 1H increased with increasing medium thickness, while decreased for 12C, 14N and 16O nuclei. The bulges in the interaction fractions with 12C, 14N and 16O nuclei were explained by the resonance spikes in the interaction cross-section data. The interaction fraction decreased in the order: 1H > 16O > 12C > 14N. (2) In general, as the medium thickness increased, the number of "interacting neutrons" which exited the medium and then further interacted with the cell layer increased. (3) The area under the angular distributions for "interacting neutrons" decreased with increasing incident neutron energy. Such results would be useful for deciphering the reasons behind discrepancies among existing results in the literature.


Assuntos
Método de Monte Carlo , Nêutrons , Radiobiologia/métodos , Algoritmos , Animais , Núcleo Celular/efeitos da radiação , Células Cultivadas , Simulação por Computador , Humanos , Radiometria/métodos , Água/química
12.
PLoS One ; 12(3): e0174836, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28362837

RESUMO

Radiotherapy is a common cancer treatment module, where a certain amount of dose will be delivered to the targeted organ. This is achieved usually by photons generated by linear accelerator units. However, radiation scattering within the patient's body and the surrounding environment will lead to dose dispersion to healthy tissues which are not targets of the primary radiation. Determination of the dispersed dose would be important for assessing the risk and biological consequences in different organs or tissues. In the present work, the concept of conversion coefficient (F) of the dispersed dose was developed, in which F = (Dd/Dt), where Dd was the dispersed dose in a non-targeted tissue and Dt is the absorbed dose in the targeted tissue. To quantify Dd and Dt, a comprehensive model was developed using the Monte Carlo N-Particle (MCNP) package to simulate the linear accelerator head, the human phantom, the treatment couch and the radiotherapy treatment room. The present work also demonstrated the feasibility and power of parallel computing through the use of the Message Passing Interface (MPI) version of MCNP5.


Assuntos
Fótons , Radioterapia/métodos , Modelos Teóricos , Método de Monte Carlo
13.
PLoS One ; 11(6): e0157627, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27362656

RESUMO

Monte Carlo method has been used to determine the efficiency for proton production and to study the energy and angular distributions of the generated protons. The ENDF library of cross sections is used to simulate the interactions between the neutrons and the atoms in a polyethylene (PE) layer, while the ranges of protons with different energies in PE are determined using the Stopping and Range of Ions in Matter (SRIM) computer code. The efficiency of proton production increases with the PE layer thickness. However the proton escaping from a certain polyethylene volume is highly dependent on the neutron energy and target thickness, except for a very thin PE layer. The energy and angular distributions of protons are also estimated in the present paper, showing that, for the range of energy and thickness considered, the proton flux escaping is dependent on the PE layer thickness, with the presence of an optimal thickness for a fixed primary neutron energy.


Assuntos
Polietileno/química , Radiometria/métodos , Método de Monte Carlo , Nêutrons , Prótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA