Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 12(21)2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36364517

RESUMO

Colloidal AgBiS2 nanocrystals (NCs) have attracted increasing attention as a near-infrared absorbent materials with non-toxic elements and a high absorption coefficient. In recent years, colloidal AgBiS2 NCs have typically been synthesized via the hot injection method using hexamethyldisilathiane (TMS) as the sulfur source. However, the cost of TMS is one of the biggest obstacles to large-scale synthesis of colloidal AgBiS2 NCs. Herein, we synthesized colloidal AgBiS2 NCs using oleylamine@sulfur (OLA-S) solution as the sulfur source instead of TMS and optimized the synthesis conditions of colloidal AgBiS2 NCs. By controlling the reaction injection temperature and the dosage of OLA-S, colloidal AgBiS2 NCs with adjustable size can be synthesized. Compared with TMS-based colloidal AgBiS2 NCs, the colloidal AgBiS2 NCs based on OLA-S has good crystallinity and fewer defects.

2.
Sensors (Basel) ; 21(23)2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34883975

RESUMO

In earthquake monitoring, an important aspect of the operational effect of earthquake intensity rapid reporting and earthquake early warning networks depends on the density and performance of the deployed seismic sensors. To improve the resolution of seismic sensors as much as possible while keeping costs low, in this article the use of multiple low-cost and low-resolution digital MEMS accelerometers is proposed to increase the resolution through the correlation average method. In addition, a cost-effective MEMS seismic sensor is developed. With ARM and Linux embedded computer technology, this instrument can cyclically store the continuous collected data on a built-in large-capacity SD card for approximately 12 months. With its real-time seismic data processing algorithm, this instrument is able to automatically identify seismic events and calculate ground motion parameters. Moreover, the instrument is easy to install in a variety of ground or building conditions. The results show that the RMS noise of the instrument is reduced from 0.096 cm/s2 with a single MEMS accelerometer to 0.034 cm/s2 in a bandwidth of 0.1-20 Hz by using the correlation average method of eight low-cost MEMS accelerometers. The dynamic range reaches more than 90 dB, the amplitude-frequency response of its input and output within -3 dB is DC -80 Hz, and the linearity is better than 0.47%. In the records from our instrument, earthquakes with magnitudes between M2.2 and M5.1 and distances from the epicenter shorter than 200 km have a relatively high SNR, and are more visible than they were prior to the joint averaging.

3.
Sensors (Basel) ; 21(19)2021 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-34640915

RESUMO

Traditional fluxgate sensors used in geomagnetic field observations are large, costly, power-consuming and often limited in their use. Although the size of the micro-fluxgate sensors has been significantly reduced, their performance, including indicators such as accuracy and signal-to-noise, does not meet observational requirements. To address these problems, a new race-track type probe is designed based on a magnetic core made of a Co-based amorphous ribbon. The size of this single-component probe is only Φ10 mm × 30 mm. The signal processing circuit is also optimized. The whole size of the sensor integrated with probes and data acquisition module is Φ70 mm × 100 mm. Compared with traditional fluxgate and micro-fluxgate sensors, the designed sensor is compact and provides excellent performance equal to traditional fluxgate sensors with good linearity and RMS noise of less than 0.1 nT. From operational tests, the results are in good agreement with those from a standard fluxgate magnetometer. Being more suitable for modern dense deployment of geomagnetic observations, this small-size fluxgate sensor offers promising research applications at lower costs.


Assuntos
Magnetismo , Processamento de Sinais Assistido por Computador
4.
ISA Trans ; 104: 222-232, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32402436

RESUMO

System reliability assessment plays a crucial role in making maintenance decisions and reducing hazard frequencies. Although many engineering methods can effectively evaluate the process reliability, most of them are often unreasonable for closed-loop systems because of the combination of closed-loop structures, maintenance characteristics, and dynamic failure mechanisms. Also, uncertainties generally exist in the reliability assessment due to the insufficient reliability data and expert knowledge. Therefore, an integrated approach is proposed in present works to assess the dynamic reliability of repairable closed-loop systems with the consideration of uncertainties. Firstly, Bayesian inference and fuzzy theorem are developed to characterize system uncertainties and estimate lifetime parameters of components. After that, a closed-loop probabilistic reliability assessment (CPRA) method is proposed for the dynamic reliability assessment of closed-loop systems by integrating cyclic Bayesian network modeling and dynamic Bayesian network solving. Besides, a novel non-probabilistic reliability assessment (NPRA) approach based on the probabilistic method and Monte Carlo simulation is presented to make maintenance decisions for repairable systems. Finally, an application of reliability assessment for the offshore crude oil separation system is introduced to verify the proposed methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA