Int J Nurs Pract ; 18(6): 574-81, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23181959

RESUMO

The aims of this descriptive study were to determine the academic profile of nurses in a university hospital, assess their level of knowledge about magnetic resonance imaging (MRI) and verify whether this knowledge was acquired during their undergraduate or graduate education. Ninety randomly selected nurses working in inpatient wards and outpatient units of a university hospital participated in the study. Data were collected through a questionnaire completed by the participants between August and October 2009. Most nurses were females who have received specialized education. The participants had a limited knowledge about MRI, which was restricted to the procedures to prepare patients for MRI examination and MRI contraindications. Most of the nurses acquired information about MRI during the professional practice. The majority of nurses showed interest to know more about the MRI examination, especially regarding the exam environment, conditions and contraindications, in order to prevent accidents.


Assuntos
Competência Clínica , Imageamento por Ressonância Magnética , Enfermeiras e Enfermeiros , Adulto , Brasil , Pesquisa em Enfermagem Clínica , Contraindicações , Educação Continuada em Enfermagem , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Recursos Humanos de Enfermagem Hospitalar
2.
Radiol. bras ; 42(5): 289-294, set.-out. 2009. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-530175

RESUMO

OBJETIVO: Avaliar a eficácia da sequência de ressonância magnética com três excitações, para obtenção de volumes e massas ventriculares, em indivíduos com respiração livre, sem apneia. MATERIAIS E MÉTODOS: Em 32 voluntários sadios, foram comparados os volumes e massas do ventrículo esquerdo, obtidos por meio de duas sequências de ressonância magnética em modo cine. A primeira, tradicionalmente utilizada e considerada padrão, em apneia e com excitação única, e a segunda, em respiração livre e com três excitações. Três leitores, com diferentes níveis de experiência, testaram a concordância e a reprodutibilidade. Para a análise estatística foram utilizados o coeficiente de correlação intraclasse, o teste t-pareado, os gráficos de Bland-Altman e o teste do sinal. RESULTADOS: Para os dois observadores mais experientes, os coeficientes de correlação intraclasse foram superiores a 0,913, assim como os níveis descritivos do teste t-pareado acima de 0,05, os gráficos de Bland-Altman com as diferenças distribuídas aleatoriamente em torno do zero e o teste do sinal com seu nível descritivo superior a 0,05. CONCLUSÃO: A sequência testada apresenta ótima concordância e reprodutibilidade em relação à sequência padrão, podendo ser aplicada em indivíduos com limitações respiratórias.


OBJECTIVE: To evaluate the efficacy of free-breathing magnetic resonance sequence with three excitations in the determination of ventricular volumes and masses in individuals without breathholding. MATERIALS AND METHODS: Left ventricular volumes and masses determined in 32 healthy volunteers through two cine magnetic resonance imaging sequences were compared: the first sequence, traditionally utilized and considered as a standard, performed under apnea, with a single excitation, and the second one, with free-breathing and three excitations. Three observers at different levels of experience evaluated the agreement and reproducibility. Intraclass correlation coefficient, paired t-test, Bland-Altman plots and sign test were utilized for statistical analysis. RESULTS: According to the two most experienced observers, intraclass correlation coefficients were > 0.913, the paired t-test demonstrated P values > 0.05, Bland-Altman plots had differences randomly distributed around zero and the sign test descriptive levels were > 0.05. CONCLUSION: The sequence evaluated presents an excellent agreement and reproducibility as compared with the standard sequence, and can be utilized in patients with respiratory limitations.


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Apneia/diagnóstico , Apneia/patologia , Insuficiência Cardíaca Sistólica/diagnóstico , Insuficiência Cardíaca Sistólica/patologia , Ecocardiografia/métodos , Espectroscopia de Ressonância Magnética/métodos
3.
Radiol. bras ; 40(6): 377-381, nov.-dez. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-471996

RESUMO

OBJETIVO: Medir a concordância intra- e interobservador da classificação ultra-sonográfica qualitativa para graduar a fibrose periportal adotada no encontro de Niamey em 1996. MATERIAIS E MÉTODOS: No período de fevereiro de 2005 a março de 2006 foi realizado estudo prospectivo, observacional e transversal em 30 pacientes esquistossomóticos, sem outras hepatopatias associadas, submetidos a ultra-sonografia abdominal e classificados segundo os critérios de Niamey. Os exames foram realizados por dois radiologistas de forma independente em diferentes momentos: durante o exame dinâmico (primeiro momento) e 30 e 90 dias depois (segundo e terceiro momentos) do exame, por meio da documentação fotográfica analisada em estação de trabalho. A concordância intra- e interobservador foi avaliada pelo teste kappa. RESULTADOS: A concordância intra-observador medida pelo teste kappa foi 0,43 para o observador 1 e 0,57 para o observador 2. A concordância interobservador durante o estudo dinâmico e na avaliação fotográfica foi, respectivamente, de 0,46 e 0,71. CONCLUSÃO: O uso do ultra-som para classificar a fibrose periportal segundo o protocolo de Niamey apresentou uma reprodutibilidade que variou de moderada a substancial.


OBJECTIVE: To determine the intra- and interobserver agreement in the classification of periportal fibrosis, according to the criteria defined at the Niamey Workshop of 1996. MATERIALS AND METHODS: A prospective, observational and transverse study was developed in the period between February, 2005 and March, 2006, in 30 schistosomal patients with no other hepatic findings associated, submitted to abdominal ultrasound. Ultrasonographic studies were independently performed and reviewed by two radiologists at three different moments: the dynamic examination itself (first moment), 30 and 90 days later (second and third moments), by means of the images review performed in a workstation. Intra- and interobserver agreement was evaluated by means of the kappa test. RESULTS: Intraobserver agreement was 0.43 for the first, and 0.57 for the second observer. Interobserver agreement as regards the dynamic examination and images review was respectively 0.46 and 0.71. CONCLUSION: Ultrasonography demonstrated moderate to substantial reproducibility in the classification of periportal fibrosis according to the Niamey criteria.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Esquistossomose mansoni/epidemiologia , Esquistossomose mansoni/patologia , Esquistossomose mansoni , Reprodutibilidade dos Testes , Esquistossomose mansoni , Brasil , Estudos Transversais , Fibrose , Estudos Observacionais como Assunto , Estudos Prospectivos
4.
Radiol. bras ; 40(6): 383-387, nov.-dez. 2007. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-471997

RESUMO

OBJETIVO: Medir a reprodutibilidade da tomografia computadorizada sem e com contraste na avaliação da gravidade da pancreatite aguda. MATERIAIS E MÉTODOS: Cinqüenta e um exames de tomografia computadorizada abdominal sem e com contraste de pacientes com pancreatite aguda foram analisados por dois radiologistas (observadores 1 e 2). Calculamos o índice morfológico pela tomografia computadorizada sem e com contraste, separadamente, e o índice de gravidade da tomografia computadorizada para pancreatite aguda. Medimos a reprodutibilidade intra- e interobservador da tomografia computadorizada através do índice kappa (kapa). RESULTADOS: Para a concordância interobservador obtivemos kapa de 0,666, 0,705, 0,648, 0,547 e 0,631 para índice morfológico sem e com contraste, presença de necrose pancreática, extensão da necrose pancreática e índice de gravidade da tomografia computadorizada, respectivamente. Para a concordância intra-observador dos observadores 1 e 2 obtivemos, respectivamente, kapa de 0,796 e 0,732 para o índice morfológico sem contraste; 0,725 e 0,802 para o índice morfológico com contraste; 0,674 e 0,849 para a presença de necrose pancreática; 0,606 e 0,770 para a extensão da necrose pancreática; e 0,801 e 0,687 para o índice de gravidade da tomografia computadorizada. CONCLUSÃO: O estadiamento da pancreatite aguda pela tomografia computadorizada por meio do índice morfológico e do índice de gravidade da tomografia computadorizada é um método bastante reprodutível. O não-uso do contraste não afeta a reprodutibilidade da tomografia computadorizada para o cálculo do índice morfológico.


OBJECTIVE: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. MATERIALS AND METHODS: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (kappa). RESULTS: Interobserver agreement was kappa = 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was kappa = 0.796 and 0.732 for unenhanced morphological index; kappa = 0.725 and 0.802 for contrast-enhanced morphological index; kappa = 0.674 and 0.849 for presence of pancreatic necrosis; kappa = 0.606 and 0.770 for pancreatic necrosis extension; and kappa = 0.801 and 0.687 for disease severity index at computed tomography. CONCLUSION: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast-enhancement does not affect the computed tomography morphological index reproducibility.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Meios de Contraste , Pancreatite/diagnóstico , Pancreatite/terapia , Reprodutibilidade dos Testes , Tomografia Computadorizada Espiral/métodos , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA