RESUMO
PURPOSE: The purpose of the present study was to evaluate the feasibility of gated blood pool single-photon emission computed tomography (GBPS) with low-dose dobutamine (LDD) stress test, performed on a single-photon emission computed tomography (SPECT) camera equipped with cadmium-zinc-telluride (CZT) solid-state detectors, in assessing of left ventricle (LV) contractile reserve in patients with ischemic cardiomyopathy (ICM). METHODS: A total of 52 patients (age 59 ± 7.2 years, 47 men and 5 women) with ICM and a control group of 10 patients without obstructive coronary artery lesion underwent GBPS and transthoracic echocardiography (TTE) at rest and during LDD stress test (5, 10, 15 µg/kg/min). The duration of each GBPS step was 5 min. Stress-induced changes in LV ejection fraction (ΔLVEF), peak ejection rate, LV volumes, and mechanical dyssynchrony (phase histogram standard deviation, phase histogram bandwidth and entropy) obtained with GBPS were estimated. RESULTS: All GBPS indices except end-diastolic volume showed significant dynamics during stress test in both groups. The majority of parameters in ICM patients showed significant changes at a dobutamine dose of 10 µg/kg/min as compared to the rest study. Seventeen percent of ICM patients, but none from the control group, showed a decrease in LVEF during stress, accompanied by a significant increase in entropy. The intra- and inter-observer reproducibility was excellent for both rest and stress studies. There was a moderate correlation (r = 0.5, p = 0.01) between GBPS and TTE, with a mean difference value of - 1.7 (95% confidence interval - 9.8; 6.4; p = 0.06) in ΔLVEF. CONCLUSION: Low-dose dobutamine stress GBPS performed with high-efficiency CZT-SPECT cameras can be performed for evaluating stress-induced changes in LV contractility and dyssynchrony with lower acquisition time. A dobutamine dose of 10 µg/kg/min can potentially suffice to detect stress-induced changes in patients with ICM during GBPS. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04508608 (August 7, 2020).