Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Sci Rep ; 14(1): 994, 2024 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200067

RESUMO

Prediction of lower third molar eruption is crucial for its timely extraction. Therefore, the primary aim of this study was to investigate the prediction of lower third molar eruption and its uprighting with the assistance of an artificial intelligence (AI) tool. The secondary aim was identifying the incidence of fully erupted lower third molars with hygienic cleansability. In total, 771 patients having two panoramic radiographs were recruited, where the first radiograph was acquired at 8-15 years of age (T1) and the second acquisition was between 16 and 23 years (T2). The predictive model for third molar eruption could not be obtained as few teeth reached full eruption. However, uprighting model at T2 showed that in cases with sufficient retromolar space, an initial angulation of < 32° predicted uprighting. Full eruption was observed for 13.9% of the teeth, and only 1.7% showed hygienic cleansability. The predictions model of third molar uprighting could act as a valuable aid for guiding a clinician with the decision-making process of extracting third molars which fail to erupt in an upright fashion. In addition, a low incidence of fully erupted molars with hygienic cleansability suggest that a clinician might opt for prophylactic extraction.


Assuntos
Inteligência Artificial , Dente Serotino , Humanos , Lactente , Dente Serotino/diagnóstico por imagem , Estudos Retrospectivos , Erupção Dentária , Dente Molar
3.
Artigo em Inglês | MEDLINE | ID: mdl-37927146

RESUMO

AIM: To introduce an objective method to evaluate the accuracy of implant position assessment in partially edentulous patients by comparing different techniques (conventional impression, intraoral scan, CBCT) to a reference 3D model obtained with an industrial scanner, the latter mimicking the clinical situation. MATERIALS AND METHODS: Twenty-nine implants were placed in four human cadaver heads using a fully guided flapless protocol. Implant position was assessed using (a) a conventional impression, (b) an intraoral scan, and (c) CBCT and compared to an industrial scan. Three-dimensional models of intraoral scan body and implant were registered to the arch models and the deviation at implant shoulder, apex, and the angle of deviation were compared to each other as well as to the reference model. RESULTS: The three assessment techniques showed statistically significant deviations (p < .01) from the industrial scan, for all measurements, with no difference between the techniques. The maximum deviation at the implant shoulder was 0.16 mm. At the implant apex this increased to 0.38 mm. The intraoral scan deviated significantly more than the CBCT (0.12 mm, p < .01) and the conventional impression (0.10 mm, p = .02). The maximum implant angle deviation was 1.0°. The intraoral scan deviated more than the conventional impression (0.3°, p = .02). CONCLUSION: All assessment techniques deviated from the reference industrial scan, but the differences were relatively small. Intraoral scans were slightly less accurate than both conventional impressions and CBCT. Depending on the application, however, this inaccuracy may not be clinically relevant.

4.
Cleft Palate Craniofac J ; 60(4): 386-394, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34873962

RESUMO

To three-dimensionally assess and visualize the eruption path and development of the maxillary canine following alveolar bone grafting in patients born with cleft lip and palate. A further objective of this analysis was to assess how the presence of the lateral incisor impacts the eruption path of the canine.Observational follow-up study.Stockholm Craniofacial Team, Karolinska University Hospital, Sweden.Thirty children born with non-syndromic unilateral cleft lip with or without palate were consecutively included.CBCT scans of the maxilla were taken six months before and six months after the alveolar bone-grafting surgery for each patient.Canine eruption (angulation and vertical movement) and canine development (length and volume).There was a significant difference pre- and post-operatively of the canine angulation between the cleft and non-cleft sides. The mean angulation on the cleft side was 14.7° (SD = 11.1°) while on the non-cleft side, it was 4.9° (SD = 9.2°). No significant differences were noted between cleft-side and non-cleft side canines in terms of amount of vertical eruption and volumetric development. Absence of the lateral incisor did not significantly contribute to either canine angulation or its vertical eruption on the cleft-side.Higher angulation of the canine on the cleft side indicates a higher risk of future canine impaction. Presence or absence of the lateral incisor did not significantly affect canine angulation or its vertical eruption. Increased age and children born with total cleft lip and palate imply a higher risk of angulated canines on the cleft side.


Assuntos
Enxerto de Osso Alveolar , Fenda Labial , Fissura Palatina , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Fenda Labial/diagnóstico por imagem , Fenda Labial/cirurgia , Fissura Palatina/diagnóstico por imagem , Fissura Palatina/cirurgia , Dente Canino/diagnóstico por imagem , Seguimentos
5.
BMC Med Imaging ; 21(1): 23, 2021 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-33568085

RESUMO

BACKGROUND: Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone defects in an animal model. METHODS: Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant. RESULTS: Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI 0.86-0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95% CI 0.67-0.91). CONCLUSIONS: The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification, and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.


Assuntos
Perda do Osso Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Mandíbula/diagnóstico por imagem , Doenças Mandibulares/diagnóstico por imagem , Peri-Implantite/diagnóstico por imagem , Animais , Implantes Dentários , Cães , Masculino , Modelos Animais , Prognóstico , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Clin Exp Dent Res ; 7(3): 285-292, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33452746

RESUMO

OBJECTIVE: The aim of this study was to propose and validate a three-dimensional (3D) methodology for the assessment of canine eruption in patients born with unilateral cleft lip and palate (UCLP) following secondary alveolar bone graft (SABG). METHODS AND MATERIALS: A total of 10 patients (four females, six males; mean age: 8.8 years) with UCLP who underwent SABG were recruited. Pre- and 6-month post-operative cone-beam computed tomography (CBCT) was acquired for all patients. Post-operative data was registered onto pre-operative data utilizing voxel-based registration. Following superimposition, a segmentation process was applied to segment maxillary canine on both cleft and non-cleft side. Thereafter, translational and rotational changes in canine position were assessed for both cleft and non-cleft side by two observers. RESULTS: The intra-class correlation coefficient (ICC) indicated excellent reliability (≥0.90) with inter and intra-observer error of less than 0.05 mm. The overall ICC was found to be high for assessing both translational and rotational changes. The mean absolute inter- and intra-observer difference for translational and rotational changes was found to be less than 1 mm and 3°. CONCLUSION: The present method was found to be reliable proving to be clinically applicable for assessing maxillary canine eruption changes in both cleft and non-cleft bone.


Assuntos
Enxerto de Osso Alveolar , Fenda Labial , Fissura Palatina , Criança , Fenda Labial/diagnóstico por imagem , Fenda Labial/cirurgia , Fenda Labial/veterinária , Fissura Palatina/diagnóstico por imagem , Fissura Palatina/cirurgia , Fissura Palatina/veterinária , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
7.
Imaging Sci Dent ; 48(4): 261-268, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30607350

RESUMO

PURPOSE: To determine the impact of an image processing technique on diagnostic accuracy of digital panoramic radiographs for the assessment of anatomical structures in paediatric patients with mixed dentition. MATERIALS AND METHODS: The study consisted of 50 digital panoramic radiographs of children aged from 6 to 12 years, which were later on processed using a dedicated image processing method. A modified clinical image quality evaluation chart was used to evaluate the diagnostic accuracy of anatomical structures in maxillary and mandibular anterior and maxillary premolar region of processed images. RESULTS: A statistically significant difference was observed between pre and post-processed evaluation of anatomical structures (P<0.05) in the maxillary and mandibular anterior region. The anterior region was found to be more accurate in post-processed images. No significant difference was observed in the maxillary premolar region (P>0.05). The Inter-observer and intra-observer reliability of both pre and post processed images were excellent (>0.82) for anterior region and good (>0.63) for premolar region. CONCLUSION: The application of image processing technique in digital panoramic radiography can be considered a reliable method for improving the quality of anatomical structures in paediatric patients with mixed dentition.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA