J Digit Imaging ; 34(6): 1376-1386, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34647199

RESUMO

When preprocedural images are overlaid on intraprocedural images, interventional procedures benefit in that more structures are revealed in intraprocedural imaging. However, image artifacts, respiratory motion, and challenging scenarios could limit the accuracy of multimodality image registration necessary before image overlay. Ensuring the accuracy of registration during interventional procedures is therefore critically important. The goal of this study was to develop a novel framework that has the ability to assess the quality (i.e., accuracy) of nonrigid multimodality image registration accurately in near real time. We constructed a solution using registration quality metrics that can be computed rapidly and combined to form a single binary assessment of image registration quality as either successful or poor. Based on expert-generated quality metrics as ground truth, we used a supervised learning method to train and test this system on existing clinical data. Using the trained quality classifier, the proposed framework identified successful image registration cases with an accuracy of 81.5%. The current implementation produced the classification result in 5.5 s, fast enough for typical interventional radiology procedures. Using supervised learning, we have shown that the described framework could enable a clinician to obtain confirmation or caution of registration results during clinical procedures.


Assuntos
Diagnóstico por Imagem , Aprendizado de Máquina Supervisionado , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física)
2.
Abdom Radiol (NY) ; 46(7): 3437-3447, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33606061

RESUMO

PURPOSE: To evaluate 18F-fluorodeoxyglucose (FDG) perfusion PET during FDG PET/CT-guided liver tumor microwave ablation procedures for assessing the ablation margin and correlating minimum margin measurements with local progression. METHODS: This IRB-approved, HIPAA-compliant study included 20 adult patients (11 M, 9 F; mean age 65) undergoing FDG PET/CT-guided liver microwave ablation to treat 31 FDG-avid tumors. Intraprocedural FDG perfusion PET was performed to assess the ablation margin. Intraprocedural decisions regarding overlapping ablations were recorded. Two readers retrospectively interpreted intraprocedural perfusion PET and postprocedural contrast-enhanced MRI. Assessability of the ablation margin and minimum margin measurements were recorded. Imaging follow-up for local progression ranged from 30 to 574 days (mean 310). Regression modeling of minimum margin measurements was performed. Hazard ratios were calculated to correlate an ablation margin threshold of 5 mm with outcomes. RESULTS: Intraprocedural perfusion PET prompted additional overlapping ablations of two tumors, neither of which progressed. Incomplete ablation or local progression occurred in 8/31 (26%) tumors. With repeat ablation, secondary efficacy was 26 (84%) of 31. Both study readers deemed ablation margins fully assessable more often using perfusion PET than MRI (OR 69.7; CI 6.0, 806.6; p = 0.001). Minimum ablation margins ≥ 5 mm on perfusion PET correlated with a low risk of incomplete ablation/local progression by both study readers (HR 0.08 and 0.02, p < 0.001). CONCLUSION: Intraprocedural FDG perfusion PET consistently enabled complete liver tumor microwave ablation margin assessments, and the perfusion PET minimum ablation margin measurements correlated well with local outcomes. Clinical trial registration clinicaltrials.gov (NCT02018107).


Assuntos
Fluordesoxiglucose F18 , Neoplasias Hepáticas , Adulto , Idoso , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Perfusão , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos
3.
Radiology ; 288(1): 138-145, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29613843

RESUMO

Purpose To prospectively determine whether nitrogen 13 (13N) ammonia perfusion positron emission tomography (PET) during fluorine 18 fluorodeoxyglucose (FDG) PET/computed tomography (CT)-guided liver tumor ablation can be used to intraprocedurally assess ablation margins. Materials and Methods Eight patients (five women and three men; age range, 36-74 years; mean age, 57 years) were enrolled in this pilot study and underwent FDG PET/CT-guided microwave ablation of 11 FDG-avid liver metastases (mean diameter, 22 mm; range, 11-34 mm). All procedures were performed between March 2014 and December 2016. Complete ablation margin visibility and minimum ablation margin thickness were assessed by using intraprocedural 13N-ammonia perfusion PET compared with 24-hour postprocedural MR imaging by two independent blinded radiologists. Local tumor progression for each ablated tumor was assessed at follow-up imaging for 3-38 months (median, 17.6 months). Descriptive analysis was performed. Results Eleven of 11 (100%) ablation margins were fully assessable by using intraprocedural perfusion PET by both readers; six of eleven (55%) margins were fully assessable by both readers at postprocedural 24-hour MR imaging. By using perfusion PET, one tumor that had been judged by both readers to have a minimum margin of 0 mm progressed locally. No tumors judged to have a minimum margin greater than 0 mm at perfusion PET progressed locally. Conclusion 13N-ammonia perfusion PET during FDG PET/CT-guided liver tumor ablations can potentially be used to intraprocedurally assess the entire ablation margin, including the minimum margin. © RSNA, 2018.


Assuntos
Técnicas de Ablação/métodos , Fluordesoxiglucose F18 , Neoplasias Hepáticas/diagnóstico por imagem , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons/métodos , Radiografia Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/cirurgia , Masculino , Micro-Ondas , Pessoa de Meia-Idade , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos
5.
Abdom Radiol (NY) ; 41(7): 1333-7, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27315094

RESUMO

OBJECTIVE: To assess the safety and cost savings of using wall suction and plastic canisters instead of evacuated bottles, currently in short supply, to drain, and collect large amounts of fluid during image-guided paracentesis procedures. MATERIALS AND METHODS: In a hospital-based practice, 551 image-guided paracenteses were performed in 191 consecutive patients over a 10-month period, using wall suction to facilitate drainage. Total volume of fluid removed and complications were recorded. Complications were graded using Common Terminology Criteria for Adverse Events. The pressure generated from the wall suction at our institution was measured using a manometer and compared to that of an empty evacuated bottle. Cost savings per procedure were estimated by calculating the difference in the price of supplies used to collect the average volume of fluid removed per procedure for each method. RESULTS: The mean volume of fluid removed per procedure was 3541 mL. Four (0.72%) complications occurred in 551 procedures. One grade I complication consisted of a prolonged puncture site leak of ascites. Three Grade III complications included infection, hypotension, and atrial fibrillation. All four complications appeared unrelated to the use of wall suction and were treated successfully. Maximum pressure generated from the wall suction at our institution was less than the initial pressure generated from an empty evacuated bottle. Estimated cost savings per procedure was $33.92. CONCLUSION: The use of wall suction and plastic canisters to drain and collect fluid during image-guided therapeutic paracenteses is a safe alternative to using evacuated glass bottles and reduces per-procedure costs.


Assuntos
Ascite/cirurgia , Paracentese/métodos , Radiografia Intervencionista , Instrumentos Cirúrgicos/economia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Ascite/diagnóstico por imagem , Ascite/etiologia , Redução de Custos , Drenagem , Feminino , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Paracentese/instrumentação , Complicações Pós-Operatórias , Melhoria de Qualidade , Estudos Retrospectivos , Sucção
6.
J Vasc Interv Radiol ; 25(9): 1449-55, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24906627

RESUMO

PURPOSE: To assess safety and effectiveness of percutaneous image-guided cryoablation of hepatic tumors adjacent to the gallbladder. MATERIALS AND METHODS: Twenty-one cryoablation procedures were performed to treat 19 hepatic tumors (mean size, 2.7 cm; range, 1.0-5.0 cm) adjacent to the gallbladder in 17 patients (11 male; mean age, 59.2 y; range, 40-82 y) under computed tomography (n = 15) or magnetic resonance imaging (n = 6) guidance in a retrospective study. All tumors (mean size, 2.67 cm; range, 1.0-5.0 cm) were within 1 cm (mean, 0.4 cm) of the gallbladder; seven (33%) were contiguous with the gallbladder. Primary outcomes included complication rate and severity and postprocedure gallbladder imaging findings. Secondary outcomes included technical success and technique effectiveness at 6 months. RESULTS: Complications occurred in six of 21 procedures (29%); one (5%) was severe. Ice balls extended into the gallbladder lumen in 20 of 21 procedures (95%); no gallbladder-related complications occurred. The most common gallbladder imaging finding was mild, asymptomatic focal wall thickening after nine of 21 procedures (42%), which resolved on follow-up. Technical success was achieved in 19 of 21 sessions (90%). Six-month follow-up was available for 16 tumors; of these, all but two (87%) had no imaging evidence of local tumor progression. CONCLUSIONS: Percutaneous cryoablation of hepatic tumors adjacent to the gallbladder can be performed safely and successfully. Although postprocedural gallbladder changes are common, they are self-limited and clinically inconsequential, even when the ice ball extends into the gallbladder lumen.


Assuntos
Carcinoma Hepatocelular/cirurgia , Criocirurgia/métodos , Vesícula Biliar/lesões , Neoplasias Hepáticas/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Criocirurgia/efeitos adversos , Feminino , Vesícula Biliar/patologia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imagem por Ressonância Magnética Intervencionista , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
7.
J Comput Assist Tomogr ; 36(4): 394-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22805666

RESUMO

OBJECTIVE: To describe the multidetector-row computed tomography enterographic (MD-CTE) features of the ileal-anal pouch after ileal pouch anal anastomosis (IPAA) surgery and correlate them with pouch endoscopy and histopathologic findings. METHODS: All MD-CTE examinations performed on patients who underwent IPAA from July 1, 2005 to December 1, 2010 (n = 35; 16 [45.7%] men; mean age, 37.7 years; age range, 22-72 years) were retrospectively evaluated in consensus by 2 radiologists. All studies were evaluated for the presence of multiple imaging features. Two radiographic scores were then calculated: a total radiographic score and a radiographic active inflammation score. In patients who underwent MD-CTE, pouch endoscopy, and biopsy within 30 days (n = 13), both scores were correlated with findings on pouch endoscopy and histopathology. RESULTS: Of the 35 patients, 33 (94%) had at least one MD-CTE finding of active or chronic pouch inflammation and 27 patients (77%) had at least one MD-CTE finding of active pouch inflammation. Of the 13 patients who underwent endoscopy and biopsy, the total radiographic score demonstrated a strong positive correlation with endoscopic score (r = 0.81; P = 0.001) and a moderate positive correlation with histopathologic score (r = 0.56; P = 0.047). The radiographic active inflammation score demonstrated a strong positive correlation with endoscopic score (r = 0.83; P = 0.0004), but only a weak nonsignificant positive correlation with histopathologic score (r = 0.492, P = 0.087). CONCLUSIONS: In patients who had IPAA surgery, findings on MD-CTE correlate positively with findings on pouch endoscopy and histopathology and are sensitive measures for pouch inflammation with high positive predictive value. Thus, MD-CTE can be a useful noninvasive test in the early evaluation of symptomatic patients.


Assuntos
Doenças do Colo/cirurgia , Bolsas Cólicas , Pouchite/diagnóstico por imagem , Proctocolectomia Restauradora/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Anastomose Cirúrgica , Biópsia , Meios de Contraste , Endoscopia Gastrointestinal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pouchite/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Abdom Imaging ; 37(3): 377-86, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21833729

RESUMO

Computed Tomography Enterography (CTE) and Magnetic Resonance Enterography (MRE) are currently the dominant imaging tests used in the assessment of patients with Crohn's disease. More recently, the possibility of utilizing F-18 fluorodeoxyglucose (18F-FDG) Positron Emission Tomography (PET) or PET/CT has been explored in several preliminary studies. 18F-FDG PET appears to enable reliable detection of moderate to severe inflammation in bowel segments involved by Crohn's disease. Perhaps more importantly, 18F-FDG PET has the potential to provide a noninvasive, quantitative measure of inflammation that dynamically reflects changes in Crohn's disease activity. If 18F-FDG PET proves useful in monitoring responses to medical therapy within a few days of therapy initiation, an important new role for imaging in the management of patients with Crohn's disease could emerge.


Assuntos
Doença de Crohn/diagnóstico por imagem , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X , Doença de Crohn/patologia , Doença de Crohn/terapia , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
9.
J Nucl Med ; 51(12): 1841-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21078803

RESUMO

UNLABELLED: The purpose of this study was to evaluate the diagnostic efficacy of low-dose, combined (18)F-FDG PET/CT enterography (PET/CTE), compared with CT enterography (CTE) alone, in the assessment of patients with Crohn disease. METHODS: Thirteen patients with Crohn disease were prospectively enrolled in this pilot study and underwent abdominal-pelvic (18)F-FDG PET/CTE using neutral oral and intravenous contrast medium. The effective dose from PET/CTE was 17.7 mSv for the first 4 patients and 8.31 mSv for the last 9 patients. Six patients underwent surgical resection of the bowel, and 7 patients underwent colonoscopy with biopsies within 27 d (mean, 12 d) of PET/CTE. PET/CTE and CTE images were each visually assessed for Crohn disease involvement in 54 bowel segments with pathology correlation. Extraintestinal findings were recorded. A CTE severity score, maximum standardized uptake value (SUVmax), SUVmax ratio, simplified endoscopic score, and clinical parameters were correlated with pathology inflammation grade, on a per-patient basis and on a per-bowel-segment basis, using Spearman correlation. RESULTS: In 3 (23.1%) of 13 patients, (18)F-FDG uptake using PET/CTE revealed active inflammation in a bowel segment not evident using CTE (n = 2) or revealed an enterocolic fistula missed with CTE (n = 1). Visual interpretation of both PET/CTE and CTE images detected the presence of disease in all bowel segments with more than mild inflammation (sensitivity, 100%; specificity, 89.7%; positive predictive value, 78.9%; and negative predictive value, 100%). Correlation to inflammation grade per patient was the strongest for the SUVmax ratio (0.735, P = 0.004) and SUVmax (0.67, P = 0.013), as compared with the CTE score (0.62, P = 0.024). Correlation with inflammation per bowel segment was higher for the CTE score (0.79, P < 0.0001) than the SUVmax ratio (0.62, P < 0.0001) or SUVmax (0.48, P < 0.0001). SUVmax correlated strongly with serum C-reactive protein (0.82, P = 0.023), but CTE score did not. CONCLUSION: Low-dose (18)F-FDG PET/CTE, compared with CTE, may improve the detection and grading of active inflammation in patients with Crohn disease. PET/CTE also may reveal clinically significant findings, such as enterocolic fistula, not evident on PET or CTE alone.


Assuntos
Doença de Crohn/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão/métodos , Adulto , Idoso , Colonoscopia , Meios de Contraste , Doença de Crohn/patologia , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Fluordesoxiglucose F18/administração & dosagem , Humanos , Interpretação de Imagem Assistida por Computador , Intestinos/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Radiometria , Compostos Radiofarmacêuticos/administração & dosagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS