Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Am Coll Clin Pharm ; 5(8): 812-820, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35937306

RESUMO

Clinical pharmacists are an untapped resource in the fight against health disparities. As frontline workers, they are embedded in communities and interact on a regular basis with patients managing chronic conditions. In particular, managed care clinical pharmacists have access to population-wide data to identify gaps and mobilize resources to proactively address disparities across their community. Amid the current pandemic, there have been vast inequities regarding access to the coronavirus disease 2019 (COVID-19) vaccine, particularly for low income and underserved culturally specific populations. The pandemic has provided a case study for how clinical pharmacists can collaborate across managed care and community-based settings to work toward achieving health equity. Recent data indicates that culturally specific populations have received less COVID-19 vaccines than the White population. To address this inequity, a team of clinical pharmacists at CareOregon, a health plan in Oregon that serves Medicaid, collaborated with retail pharmacists from both chain and independent pharmacies to improve COVID-19 vaccination rates for this unique population. This paper describes the process and strategies implemented to ensure vaccine access for culturally specific populations enrolled with CareOregon. Strategies to expand vaccine access to this population involved data sharing with community pharmacists, direct scheduling of culturally specific members for vaccine appointments and partnering with other stakeholders such as community-based organizations (CBOs) to provide COVID-19 vaccine confidence training. This paper also highlights the impact of the strategies to improve COVID-19 vaccination rates for this population. Lastly, challenges and barriers are addressed, as well as lessons learned from this process.

2.
Phys Med Biol ; 64(11): 115024, 2019 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-30844767

RESUMO

We performed experiments using a triplet of quadrupole permanent magnets to focus protons and compared their dose distributions with unfocused collimated beams using energies and field sizes typically employed in proton radiosurgery. Experiments were performed in a clinical treatment room wherein small-diameter proton beams were focused by a magnet triplet placed immediately upstream of a water tank. The magnets consisted of segments of Sm2Co17 rare-earth permanent magnetic material adhered into Halbach cylinders with nominal field gradients of 100, 150, 200, and 250 T m-1. Unmodulated beams with initial diameters of 3 mm-20 mm were delivered using a single scattering system with nominal energies of 127 and 157 MeV (respective ranges of ~10 cm and 15 cm in water), commonly used for proton radiosurgery at our institution. For comparison, small-diameter unfocused collimated beams were similarly delivered. Transverse and depth dose distributions were measured using radiochromic film and a diode detector, respectively, and compared between the focused and unfocused beams (UNF). The focused beams produced low-eccentricity beam spots (defined by the 80% dose contour) at Bragg depth, with full width at 80% maximum dose values ranging from 3.8 to 7.6 mm. When initial focused beam diameters were larger than matching unfocused diameters (19 of 29 cases), the focused beams peak-to-entrance dose ratios were 13% to 73% larger than UNF. In addition, in 17 of these cases the efficiency of dose delivery to the target was 1.3× to 3.3× larger. Both peak-to-entrance dose ratios and efficiency tended to increase with initial beam diameter, while efficiency also tended to increase with magnet gradient. These experimental results are consistent with our previous Monte Carlo (MC) studies and suggest that a triplet of quadrupole Halbach cylinders could be clinically useful for irradiating small-field radiosurgical targets with fewer beams, lower entrance dose, and shorter treatment times.


Assuntos
Fenômenos Magnéticos , Prótons , Radiocirurgia/métodos , Método de Monte Carlo , Água
3.
J Oral Facial Pain Headache ; 32(2): 198­207, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29466475

RESUMO

AIMS: To determine the cost effectiveness and cost utility of arthrocentesis as an initial treatment for temporomandibular joint (TMJ) arthralgia compared to usual care. METHODS: A two-armed, parallel-design, randomized controlled trial (RCT) was conducted in the Netherlands from January 2009 to June 2012 that included patients with TMJ arthralgia. Patients were randomly allocated to arthrocentesis (n = 40) or usual care (n = 40) for initial treatment. Arthrocentesis consisted of rinsing the intra-articular space with isotonic saline, and usual care included a soft diet, physical therapy, and splint therapy. The duration of the usual care program was 6 weeks, and follow-up was conducted 3, 12, and 26 weeks after its completion. Generalized estimated equation multivariate models were assessed in order to correct for the dependency of repeated measurements in the longitudinal data analysis. An independent samples t test was used to compare the arthrocentesis group with the usual care group for TMJ pain after 26 weeks. Cost effectiveness (total cost from a societal view) was related to TMJ pain (as measured on a visual analog scale [0 to 100 mm]) and to cost utility (quality-adjusted life years). RESULTS: TMJ pain declined more quickly in the arthrocentesis group (n = 36) than in the usual care group (n = 36) (regression coefficient ß = -10.76; 95% confidence interval [CI] = -17.75 to -3.77; P = .003). The estimated mean total (ie, societal) cost over 26 weeks was €589 (US $795) in the arthrocentesis group and €1,680 (US $2,266) in the usual care group. Arthrocentesis was associated with a lower mean cost and better health outcomes than usual care in 98% and 95% of the bootstrap simulations, respectively. CONCLUSION: The results of this study suggest that, from an economical perspective, arthrocentesis may be superior to usual care for the initial treatment of TMJ pain, as it had better health outcomes and lower costs than usual care.

4.
Phys Med Biol ; 63(5): 055010, 2018 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-29369047

RESUMO

The purpose of this project is to investigate the advantages in dose distribution and delivery of proton beams focused by a triplet of quadrupole magnets in the context of potential radiosurgery treatments. Monte Carlo simulations were performed using various configurations of three quadrupole magnets located immediately upstream of a water phantom. Magnet parameters were selected to match what can be commercially manufactured as assemblies of rare-earth permanent magnetic materials. Focused unmodulated proton beams with a range of ~10 cm in water were target matched with passive collimated beams (the current beam delivery method for proton radiosurgery) and properties of transverse dose, depth dose and volumetric dose distributions were compared. Magnetically focused beams delivered beam spots of low eccentricity to Bragg peak depth with full widths at the 90% reference dose contour from ~2.5 to 5 mm. When focused initial beam diameters were larger than matching unfocused beams (10 of 11 cases) the focused beams showed 16%-83% larger peak-to-entrance dose ratios and 1.3 to 3.4-fold increases in dose delivery efficiency. Peak-to-entrance and efficiency benefits tended to increase with larger magnet gradients and larger initial diameter focused beams. Finally, it was observed that focusing tended to shift dose in the water phantom volume from the 80%-20% dose range to below 20% of reference dose, compared to unfocused beams. We conclude that focusing proton beams immediately upstream from tissue entry using permanent magnet assemblies can produce beams with larger peak-to-entrance dose ratios and increased dose delivery efficiencies. Such beams could potentially be used in the clinic to irradiate small-field radiosurgical targets with fewer beams, lower entrance dose and shorter treatment times.


Assuntos
Magnetismo , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos
5.
J Appl Clin Med Phys ; 18(5): 315-324, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28719019

RESUMO

As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging.


Assuntos
Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Desenho de Equipamento , Método de Monte Carlo , Radiometria/instrumentação , Radiocirurgia/métodos , Silício
6.
Catheter Cardiovasc Interv ; 88(5): 727-737, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26773574

RESUMO

OBJECTIVE: To determine how two different types of iodinated contrast media (CM), low-osmolar ionic dimer ioxaglate (Hexabrix) and iso-osmolar non-ionic dimer iodixanol (Visipaque), affect multiple indices of hemostasis. BACKGROUND: In vitro models demonstrate differential effects of ionic and non-ionic CM on markers of hemostasis. METHODS: This blinded endpoint trial randomized 100 patients to ioxaglate or iodixanol. The primary endpoint was change in endogenous thrombin potential (ETP) following diagnostic angiography. Secondary endpoints included change in markers of fibrinolysis [tissue plasminogen activator (tPA) and plasminogen activator inhibitor 1 (PAI-1)] and platelet aggregation following diagnostic angiography and percutaneous coronary intervention (PCI) with bivalirudin. Data are presented as median [interquartile range]. RESULTS: ETP significantly decreased after diagnostic angiography in both ioxaglate (baseline 1810 nM*minute [1540-2089] to post-angiography 649 nM*minute [314-1347], p < 0.001) and iodixanol groups (baseline 1682 nM*minute [1534-2147] to post-angiography 681 nM*minute [229-1237], p < 0.001), but the decrease was not different between CM (p = 0.70). There was a significant increase in ETP during PCI (n = 45), despite the use of bivalirudin, suggesting a prothrombotic effect of PCI (post-angiography 764 nM*minute [286-1283] to post-PCI 1081 nM*minute [668-1552], p = 0.02). There were no significant differential effects on tPA, PAI-1, and markers of platelet activity. CONCLUSION: There were no significant differential effects between ioxaglate and iodixanol. Both CM led to significant reductions in thrombin generation and no significant effects on fibrinolytic activity or platelet activity, thereby contributing to a favorable antithrombotic milieu. © 2016 Wiley Periodicals, Inc.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Fibrinólise/fisiologia , Ácido Ioxáglico/farmacologia , Intervenção Coronária Percutânea/métodos , Trombose/sangue , Ácidos Tri-Iodobenzoicos/farmacologia , Idoso , Biomarcadores/sangue , Meios de Contraste/farmacologia , Doença da Artéria Coronariana/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Trombose/diagnóstico , Trombose/etiologia
7.
J Appl Clin Med Phys ; 16(6): 51-64, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699554

RESUMO

The small fields and sharp gradients typically encountered in proton radiosurgery require high spatial resolution dosimetric measurements, especially below 1-2 cm diameters. Radiochromic film provides high resolution, but requires postprocessing and special handling. Promising alternatives are diode detectors with small sensitive volumes (SV) that are capable of high resolution and real-time dose acquisition. In this study we evaluated the PTW PR60020 proton dosimetry diode using radiation fields and beam energies relevant to radiosurgery applications. Energies of 127 and 157 MeV (9.7 to 15 cm range) and initial diameters of 8, 10, 12, and 20mm were delivered using single-stage scattering and four modulations (0, 15, 30, and 60mm) to a water tank in our treatment room. Depth dose and beam profile data were compared with PTW Markus N23343 ionization chamber, EBT2 Gafchromic film, and Monte Carlo simulations. Transverse dose profiles were measured using the diode in "edge-on" orientation or EBT2 film. Diode response was linear with respect to dose, uniform with dose rate, and showed an orientation-dependent (i.e., beam parallel to, or perpendicular to, detector axis) response of less than 1%. Diodevs. Markus depth-dose profiles, as well as Markus relative dose ratio vs. simulated dose-weighted average lineal energy plots, suggest that any LET-dependent diode response is negligible from particle entrance up to the very distal portion of the SOBP for the energies tested. Finally, while not possible with the ionization chamber due to partial volume effects, accurate diode depth-dose measurements of 8, 10, and 12 mm diameter beams were obtained compared to Monte Carlo simulations. Because of the small SV that allows measurements without partial volume effects and the capability of submillimeter resolution (in edge-on orientation) that is crucial for small fields and high-dose gradients (e.g., penumbra, distal edge), as well as negligible LET dependence over nearly the full the SOBP, the PTW proton diode proved to be a useful high-resolution, real-time metrology device for small proton field radiation measurements such as would be encountered in radiosurgery applications.


Assuntos
Terapia com Prótons/métodos , Radiometria/instrumentação , Radiocirurgia/métodos , Simulação por Computador , Humanos , Transferência Linear de Energia , Modelos Lineares , Método de Monte Carlo , Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Água , Filme para Raios X
8.
Technol Cancer Res Treat ; 14(4): 447-58, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25414143

RESUMO

We previously performed Monte Carlo simulations of magnetically focused proton beams shaped by a single quadrapole magnet and thereby created narrow elongated beams with superior dose delivery characteristics (compared to collimated beams) suitable for targets of similar geometry. The present study seeks to experimentally validate these simulations using a focusing magnet consisting of 24 segments of samarium cobalt permanent magnetic material adhered into a hollow cylinder. Proton beams with properties relevant to clinical radiosurgery applications were delivered through the magnet to a water tank containing a diode detector or radiochromic film. Dose profiles were analyzed and compared with analogous Monte Carlo simulations. The focused beams produced elongated beam spots with high elliptical symmetry, indicative of magnet quality. Experimental data showed good agreement with simulations, affirming the utility of Monte Carlo simulations as a tool to model the inherent complexity of a magnetic focusing system. Compared to target-matched unfocused simulations, focused beams showed larger peak to entrance ratios (26% to 38%) and focused simulations showed a two-fold increase in beam delivery efficiency. These advantages can be attributed to the magnetic acceleration of protons in the transverse plane that tends to counteract the particle outscatter that leads to degradation of peak to entrance performance in small field proton beams. Our results have important clinical implications and suggest rare earth focusing magnet assemblies are feasible and could reduce skin dose and beam number while delivering enhanced dose to narrow elongated targets (eg, in and around the spinal cord) in less time compared to collimated beams.


Assuntos
Terapia com Prótons/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Dosagem Radioterapêutica
9.
Med Phys ; 40(4): 041701, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23556871

RESUMO

PURPOSE: Monte Carlo simulations of radiation therapy require conversion from Hounsfield units (HU) in CT images to an exact tissue composition and density. The number of discrete densities (or density bins) used in this mapping affects the simulation accuracy, execution time, and memory usage in GEANT4 and other Monte Carlo code. The relationship between the number of density bins and CT noise was examined in general for all simulations that use HU conversion to density. Additionally, the effect of this on simulation accuracy was examined for proton radiation. METHODS: Relative uncertainty from CT noise was compared with uncertainty from density binning to determine an upper limit on the number of density bins required in the presence of CT noise. Error propagation analysis was also performed on continuously slowing down approximation range calculations to determine the proton range uncertainty caused by density binning. These results were verified with Monte Carlo simulations. RESULTS: In the presence of even modest CT noise (5 HU or 0.5%) 450 density bins were found to only cause a 5% increase in the density uncertainty (i.e., 95% of density uncertainty from CT noise, 5% from binning). Larger numbers of density bins are not required as CT noise will prevent increased density accuracy; this applies across all types of Monte Carlo simulations. Examining uncertainty in proton range, only 127 density bins are required for a proton range error of <0.1 mm in most tissue and <0.5 mm in low density tissue (e.g., lung). CONCLUSIONS: By considering CT noise and actual range uncertainty, the number of required density bins can be restricted to a very modest 127 depending on the application. Reducing the number of density bins provides large memory and execution time savings in GEANT4 and other Monte Carlo packages.


Assuntos
Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Humanos , Terapia com Prótons , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador
10.
Circulation ; 123(14): 1492-500, 2011 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-21444887

RESUMO

BACKGROUND: In the Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) trial, an initial strategy of coronary revascularization and optimal medical treatment (REV) compared with an initial optimal medical treatment with the option of subsequent revascularization (MED) did not reduce all-cause mortality or the composite of cardiovascular death, myocardial infarction, and stroke in patients with type 2 diabetes mellitus and stable ischemic heart disease. In the same population, we tested whether the REV strategy was superior to the MED strategy in preventing worsening and new angina and subsequent coronary revascularizations. METHODS AND RESULTS: Among the 2364 men and women (mean age, 62.4 years) with type 2 diabetes mellitus, documented coronary artery disease, and myocardial ischemia, 1191 were randomized to the MED and 1173 to the REV strategy preselected in the percutaneous coronary intervention (796) and coronary artery bypass graft (377) strata. Compared with the MED strategy, the REV strategy at the 3-year follow-up had a lower rate of worsening angina (8% versus 13%; P<0.001), new angina (37% versus 51%; P=0.001), and subsequent coronary revascularizations (18% versus 33%; P<0.001) and a higher rate of angina-free status (66% versus 58%; P=0.003). The coronary artery bypass graft stratum patients were at higher risk than those in the percutaneous coronary intervention stratum, and had the greatest benefits from REV. CONCLUSIONS: In these patients, the REV strategy reduced the occurrence of worsening angina, new angina, and subsequent coronary revascularizations more than the MED strategy. The symptomatic benefits were observed particularly for high-risk patients. CLINICAL TRIAL REGISTRATION: URL: http://www.ClinicalTrials.gov. Unique identifier: NCT00006305.


Assuntos
Angina Pectoris/etiologia , Angina Pectoris/terapia , Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Diabetes Mellitus Tipo 2/complicações , Tratamento Farmacológico/métodos , Isquemia Miocárdica/complicações , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Angioplastia Coronária com Balão/economia , Bloqueadores dos Canais de Cálcio/uso terapêutico , Ponte de Artéria Coronária/economia , Análise Custo-Benefício , Tratamento Farmacológico/economia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Nitratos/uso terapêutico , Índice de Gravidade de Doença , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA