Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Radiol Med ; 127(3): 238-250, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35050452

RESUMO

PURPOSE: To determine the potential of magnetic resonance-enterography (MRE) in the assessment of the anastomotic status in patients with Crohn disease and prior ileocolic resection. METHODS: A total of 62 MRE examinations obtained in 52 patients with Crohn disease who had previously undergone ileocolic resection were retrospectively reviewed by two readers in consensus. MRE features (anastomotic wall thickening, wall stratification, wall enhancement pattern and degree, DWI signal intensity, ADC values, lymph nodes, comb sign and complications) were compared to clinical, endoscopic and histological findings that served as standard of reference. Sensitivity, specificity and accuracy of MRE were calculated. RESULTS: At univariate analysis, anastomotic wall thickening, anastomotic wall stratification, segmental wall enhancement, moderate wall enhancement, early and mucosal enhancement, and moderate/marked hyperintensity on diffusion-weighed imaging (DWI) were the most discriminative MRE features for differentiating between normal and abnormal anastomoses (p < 0.001 for all variables). Anastomotic wall thickening and segmental anastomotic wall enhancement were the two most sensitive and accurate MRE variables for the diagnosis of abnormal anastomosis with sensitivities of 82% (95% CI: 67-92%) and accuracies of 84% (95% CI: 72-92%). At univariate analysis, hyperintensity on DWI of the anastomotic site was the most sensitive finding for distinguishing between inflammatory recurrence and fibrostenosis (sensitivity, 89%; 95% CI: 67-99%). CONCLUSIONS: MRE provides objective and relatively specific morphological criteria that help detect abnormal ileocolic anastomosis, but performances are lower when differentiating between inflammatory recurrence and fibrostenosis. DWI may be useful in identifying pathologic anastomosis and, in particular, in distinguishing between inflammatory recurrence and fibrostenosis.


Assuntos
Doença de Crohn , Anastomose Cirúrgica , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Diagn Interv Imaging ; 102(5): 313-319, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33257202

RESUMO

PURPOSE: To compare a newly developed preoperative computed tomography physical status (CT-PS) score with the American Society of Anesthesiology performance status (ASA-PS) scale in the assessment of patient preoperative health status and stratification of perioperative risk before left colectomy. MATERIALS AND METHODS: Preoperative chest-abdomen-pelvis CT examinations of patients who were scheduled to undergo elective laparoscopic left colonic resection for cancer in two centers were reviewed by two radiologists blinded to clinical data for the presence of several key imaging features in order to assess general, cardiac, pulmonary, abdominal, renal, vascular and musculoskeletal status. CT examinations of patients from center 1 were used to build a CT-PS score to predict ASA-PS≥III. CT-PS score was further validated using an external cohort of patients from center 2. RESULTS: During a 2-year period, 117 consecutive patients (63 men, 54 women; mean age, 65±13 [SD] years; age range: 53-90 years) who underwent laparoscopic left colectomy for cancer in center 1 (66 patients, building cohort) and center 2 (51 patients, validation cohort) were retrospectively included. Ninety-one percent of patients were ASA-PS 1-2. Overall postoperative morbidity was 23% and severe morbidity 12%. The area under the receiver operating characteristic curve of CT-PS score was 0.968 (95% CI: 0.901-1.000) in the building cohort and 0.828 (95% CI: 0.693-0.963) in the validation cohort. The optimal thresholds yielded 87% (95% CI: 83-91%) sensitivity and 100% (95% CI: 91-100%) specificity in the building cohort and 75% (95% CI: 69-81%) sensitivity and 83% (95% CI: 77-88%) specificity in the validation cohort for the prediction of ASA-PS. CONCLUSION: Preoperative chest-abdomen-pelvis CT thoroughly and wisely read is highly accurate to differentiate patients with ASA-PS I/II from those with ASA-PS III/IV before left colectomy.


Assuntos
Anestesiologia , Colectomia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia , Tomografia Computadorizada por Raios X
4.
Eur J Radiol ; 110: 60-65, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30599874

RESUMO

PURPOSE: To estimate the performances of computed tomography (CT) and magnetic resonance imaging (MRI) and those of the combination of CT with MRI in the identification of splenic involvement in patients with peritoneal carcinomatosis (PC). MATERIAL AND METHOD: CT and MRI examinations of 26 patients with PC with splenic involvement and 26 patients with PC and no splenic involvement treated by total cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) were reviewed. There were 32 women and 20 men with a mean age of 53.44 ± 12.22 (SD) years (range: 20-73 years). Imaging examinations were reviewed separately as three independent imaging sets (CT only, MRI only and CT with MRI) by two independent readers. A consensus was reached during a joint reading session and these results were used for determining the performances of the three imaging sets in the diagnosis of splenic involvement using surgical and histopathological findings as standard of reference. RESULTS: Splenic involvement was histologically proven in 26/52 patients (50%). There were no significant differences in sensitivity, specificity and accuracy for the diagnosis of splenic involvement between CT, MRI and CT + MRI, with respectively 84.62%, 96.15% and 90.00% for CT, 84.62%, 84.62% and 85.00% for MRI and 92.31%, 92.31% and 92.00% for CT + MRI. CONCLUSION: CT and MRI have similar sensitivities, specificites and accuracies for the diagnosis of splenic involvement in patients with PC. The combination of CT and MRI does not significantly improve the preoperative diagnosis of splenic involvement in patients with PC compared to CT only.


Assuntos
Carcinoma/patologia , Neoplasias Peritoneais/patologia , Neoplasias Esplênicas/patologia , Adulto , Idoso , Carcinoma/terapia , Procedimentos Cirúrgicos de Citorredução/métodos , Feminino , Humanos , Hipertermia Induzida/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias Peritoneais/terapia , Cuidados Pré-Operatórios/métodos , Sensibilidade e Especificidade , Baço/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
5.
Eur Radiol ; 26(8): 2494-501, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26515550

RESUMO

OBJECTIVES: To study linear and volumetric adrenal measurements, their reproducibility, and correlations between total adrenal volume (TAV) and adrenal micronodularity, age, gender, body mass index (BMI), visceral (VAAT) and subcutaneous adipose tissue volume (SAAT), presence of diabetes, chronic alcoholic abuse and chronic inflammatory disease (CID). METHODS: We included 154 patients (M/F, 65/89; mean age, 57 years) undergoing abdominal multidetector row computed tomography (MDCT). Two radiologists prospectively independently performed adrenal linear and volumetric measurements with semi-automatic software. Inter-observer reliability was studied using inter-observer correlation coefficient (ICC). Relationships between TAV and associated factors were studied using bivariate and multivariable analysis. RESULTS: Mean TAV was 8.4 ± 2.7 cm(3) (3.3-18.7 cm(3)). ICC was excellent for TAV (0.97; 95 % CI: 0.96-0.98) and moderate to good for linear measurements. TAV was significantly greater in men (p < 0.0001), alcoholics (p = 0.04), diabetics (p = 0.0003) and those with micronodular glands (p = 0.001). TAV was lower in CID patients (p = 0.0001). TAV correlated positively with VAAT (r = 0.53, p < 0.0001), BMI (r = 0.42, p < 0.0001), SAAT (r = 0.29, p = 0.0003) and age (r = 0.23, p = 0.005). Multivariable analysis revealed gender, micronodularity, diabetes, age and BMI as independent factors influencing TAV. CONCLUSIONS: Adrenal gland MDCT-based volumetric measurements are more reproducible than linear measurements. Gender, micronodularity, age, BMI and diabetes independently influence TAV. KEY POINTS: • Volumetric measurements are more reproducible than linear measurements for adrenal glands. • Inter-observer reproducibility of adrenal gland volume is excellent using semiautomatic software. • Gender, age, BMI, and diabetes independently influence total adrenal gland volume. • Adrenal micronodularity is associated with increased total adrenal gland volume.


Assuntos
Glândulas Suprarrenais/anatomia & histologia , Glândulas Suprarrenais/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Glândulas Suprarrenais/fisiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Diabetes Mellitus/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Fatores Sexuais
6.
Ultrasound Med Biol ; 42(2): 438-46, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26626491

RESUMO

Diffuse hepatocellular carcinoma (HCC) is a complex affliction in which comorbidities can bias global outcome of cancer therapy. Better methods are thus warranted to directly assess effects of therapy on tumor angiogenesis and growth. As tumor angiogenesis is invariably associated with changes in local blood flow, we assessed the utility of ultrasound imaging in evaluation of the efficacy of anti-angiogenic therapy in a spontaneous transgenic mouse model of HCC. Blood flow velocities were measured monthly in the celiac trunk before and after administration of sorafenib or bevacizumab at doses corresponding to those currently used in clinical practice. Concordant with clinical experience, sorafenib, but not bevacizumab, reduced microvascular density and suppressed tumor growth relative to controls. Evolution of blood flow velocities correlated with microvascular density and with the evolution of tumor size. Ultrasound imaging thus provides a useful non-invasive tool for preclinical evaluation of new anti-angiogenic therapies for HCC.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/tratamento farmacológico , Neovascularização Patológica/tratamento farmacológico , Ultrassonografia/métodos , Animais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/fisiopatologia , Avaliação Pré-Clínica de Medicamentos , Circulação Hepática/efeitos dos fármacos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/fisiopatologia , Masculino , Camundongos , Camundongos Transgênicos , Neovascularização Patológica/complicações , Neovascularização Patológica/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
7.
Eur Radiol ; 26(7): 2166-75, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26662030

RESUMO

OBJECTIVES: Current methods for infarct size and microvascular obstruction (MVO) quantification by cardiac magnetic resonance (CMR) imaging rely on planimetry. This method is time-consuming. We sought to evaluate a direct assessment of MVO severity based on visual evaluation and to compare it to a reference method. METHODS: CMR was performed in 112 consecutive patients after reperfused myocardial infarction. MVO was estimated by direct visual assessment based on a three-grade severity scale (MVO 1, mild; MVO 2, moderate; MVO 3, severe) on late gadolinium-enhancement (LGE). RESULTS: MVO was present in 69 patients (61.6 %). Quantitative MVO extent significantly increased accordingly to visual MVO grading (p < 0.01). Correlation between visual grading and quantitative assessment was excellent (r = 0.92, IQR 0.88-0.95, p < 0.001). CMR inter- and intraobserver variability for visual MVO evaluation was low (κ = 0.93 and κ = 0.96, respectively), whereas quantitative MVO assessment suffered from moderate agreement (interobserver, bias = -0.81 ± 1.8 g LV; intraobserver, -0.83 ± 2.1 g LV). Visual evaluation was significantly faster than reference method (0.65 ± 0.37 vs. 10.2 ± 2.9 min, p < 0.0001). CONCLUSIONS: MVO severity based on direct visual assessment on LGE images is feasible, rapid, reproducible and agrees very well with quantitative methods, with a very low inter- and intraobserver variability. Our approach could be used for routine evaluation in patients undergoing CMR after acute myocardial infarction. KEY POINTS: • Microvascular obstruction direct visual evaluation is feasible, rapid and highly reproducible. • Microvascular obstruction direct visual evaluation correlates well with quantification by planimetry. • Microvascular obstruction or no-reflow phenomenon is determined on late gadolinium-enhanced images. • Cardiac MRI is useful for myocardial damage assessment after myocardial infarction.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Reperfusão Miocárdica , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Arteriopatias Oclusivas/diagnóstico por imagem , Meios de Contraste , Angiografia Coronária , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Reperfusão Miocárdica/métodos , Intervenção Coronária Percutânea , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Trombectomia , Terapia Trombolítica
8.
Radiographics ; 32(5): 1423-44, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22977028

RESUMO

The use of cross-sectional imaging techniques for the noninvasive evaluation of small-bowel disorders is increasing. The effectiveness of magnetic resonance (MR) enterography for the evaluation of Crohn disease, in particular, is well described in the literature. In addition, MR enterography has an evolving though less well documented role to play in the evaluation of other small-bowel diseases, including various benign and malignant neoplasms arising in isolation or in polyposis syndromes such as Peutz-Jeghers, inflammatory conditions such as vasculitis and treatment-induced enteritis, infectious processes, celiac disease, diverticular disease, systemic sclerosis, and bowel duplication. MR enterography may be useful also for the evaluation of intermittent and low-grade small-bowel obstructions. Advantages of MR imaging over computed tomography (CT) for enterographic evaluations include superb contrast resolution, lack of associated exposure to ionizing radiation, ability to acquire multiplanar primary image datasets, ability to acquire sequential image series over a long acquisition time, multiphasic imaging capability, and use of intravenous contrast media with better safety profiles. MR enterography also allows dynamic evaluations of small-bowel peristalsis and distensibility of areas of luminal narrowing and intraluminal masses by repeating sequences at different intervals after administering an additional amount of the oral contrast medium. Limitations of MR enterography in comparison with CT include higher cost, less availability, more variable image quality, and lower spatial resolution. The advantages and disadvantages of MR enterography performed with ingestion of the oral contrast medium relative to MR enteroclysis performed with infusion of the oral contrast medium through a nasoenteric tube are less certain.


Assuntos
Aumento da Imagem/métodos , Enteropatias/patologia , Intestino Delgado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA