1.
Microvasc Res ; 147: 104480, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36690270

RESUMO

OBJECTIVE: Coronary microvascular dysfunction (CMD) is a cause of ischaemia with non-obstructive coronary arteries (INOCA). It is notoriously underdiagnosed due to the need for invasive microvascular function testing. We hypothesized that systemic microvascular dysfunction could be demonstrated non-invasively in the microcirculation of the bulbar conjunctiva in patients with CMD. METHODS: Patients undergoing coronary angiography for the investigation of chest pain or dyspnoea, with physiologically insignificant epicardial disease (fractional flow reserve ≥0.80) were recruited. All patients underwent invasive coronary microvascular function testing. We compared a cohort of patients with evidence of CMD (IMR ≥25 or CFR <2.0); to a group of controls (IMR <25 and CFR ≥2.0). Conjunctival imaging was performed using a previously validated combination of a smartphone and slit-lamp biomicroscope. This technique allows measurement of vessel diameter and other indices of microvascular function by tracking erythrocyte motion. RESULTS: A total of 111 patients were included (43 CMD and 68 controls). There were no differences in baseline demographics, co-morbidities or epicardial coronary disease severity. The mean number of vessel segments analysed per patient was 21.0 ± 12.8 (3.2 ± 3.5 arterioles and 14.8 ± 10.8 venules). In the CMD cohort, significant reductions were observed in axial/cross-sectional velocity, blood flow, wall shear rate and stress. CONCLUSION: The changes in microvascular function linked to CMD can be observed non-invasively in the bulbar conjunctiva. Conjunctival vascular imaging may have utility as a non-invasive tool to both diagnose CMD and augment conventional cardiovascular risk assessment.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Estudos Transversais , Estudos Prospectivos , Hemodinâmica , Angiografia Coronária/métodos , Vasos Coronários , Microcirculação , Túnica Conjuntiva , Circulação Coronária
2.
Cardiovasc Revasc Med ; 50: 26-33, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36707373

RESUMO

BACKGROUND: Atherosclerotic heart disease often remains asymptomatic until presentation with a major adverse cardiovascular event. Primary preventive therapies improve outcomes, but conventional screening often misattributes risk. Vascular imaging can be utilised to detect atherosclerosis, but often involves ionising radiation. The conjunctiva is a readily accessible vascular network allowing non-invasive hemodynamic evaluation. AIM: To compare conjunctival microcirculatory function in patients with and without obstructive coronary artery disease. METHODS: We compared the conjunctival microcirculation of myocardial infarction patients (MI-cohort) to controls with no obstructive coronary artery disease (NO-CAD cohort). Conjunctival imaging was performed using a smartphone and slit-lamp biomicroscope combination. Microvascular indices of axial (Va) and cross-sectional (Vcs) velocity; blood flow rate (Q); and wall shear rate (WSR) were compared in all conjunctival vessels between 5 and 45 µm in diameter. RESULTS: A total of 127 patients were recruited (66 MI vs 61 NO-CAD) and 3602 conjunctival vessels analysed (2414 MI vs 1188 NO-CAD). Mean Va, Vcs and Q were significantly lower in the MI vs NO-CAD cohort (Va 0.50 ± 0.17 mm/s vs 0.55 ± 0.15 mm/s, p < 0.001; Vcs 0.35 ± 0.12 mm/s vs 0.38 ± 0.10 mm/s, p < 0.001; Q 154 ± 116 pl/s vs 198 ± 130 pl/s, p < 0.001). To correct for differences in mean vessel diameter, WSR was compared in 10-36 µm vessels (3268/3602 vessels) and was lower in the MI-cohort (134 ± 64 s-1 vs 140 ± 63 s-1, p = 0.002). CONCLUSIONS: Conjunctival microcirculatory alterations can be observed in patients with obstructive coronary artery disease. The conjunctival microvasculature merits further evaluation in cardiovascular risk screening.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Microcirculação/fisiologia , Estudos Transversais , Túnica Conjuntiva/irrigação sanguínea , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária
3.
Microvasc Res ; 136: 104167, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33838207

RESUMO

PURPOSE: Congenital heart disease (CHD) is the most common live birth defect and a proportion of these patients have chronic hypoxia. Chronic hypoxia leads to secondary erythrocytosis resulting in microvascular dysfunction and increased thrombosis risk. The conjunctival microcirculation is easily accessible for imaging and quantitative assessment. It has not previously been studied in adult CHD patients with cyanosis (CCHD). METHODS: We assessed the conjunctival microcirculation and compared CCHD patients and matched healthy controls to determine if there were differences in measured microcirculatory parameters. We acquired images using an iPhone 6s and slit-lamp biomicroscope. Parameters measured included diameter, axial velocity, wall shear rate and blood volume flow. The axial velocity was estimated by applying the 1D + T continuous wavelet transform (CWT). Results are for all vessels as they were not sub-classified into arterioles or venules. RESULTS: 11 CCHD patients and 14 healthy controls were recruited to the study. CCHD patients were markedly more hypoxic compared to the healthy controls (84% vs 98%, p = 0.001). A total of 736 vessels (292 vs 444) were suitable for analysis. Mean microvessel diameter (D) did not significantly differ between the CCHD patients and controls (20.4 ± 2.7 µm vs 20.2 ± 2.6 µm, p = 0.86). Axial velocity (Va) was lower in the CCHD patients (0.47 ± 0.06 mm/s vs 0.53 ± 0.05 mm/s, p = 0.03). Blood volume flow (Q) was lower for CCHD patients (121 ± 30pl/s vs 145 ± 50pl/s, p = 0.65) with the greatest differences observed in vessels >22 µm diameter (216 ± 121pl/s vs 258 ± 154pl/s, p = 0.001). Wall shear rate (WSR) was significantly lower for the CCHD group (153 ± 27 s-1 vs 174 ± 22 s-1, p = 0.04). CONCLUSIONS: This iPhone and slit-lamp combination assessment of conjunctival vessels found lower axial velocity, wall shear rate and in the largest vessel group, lower blood volume flow in chronically hypoxic patients with congenital heart disease. With further study this assessment method may have utility in the evaluation of patients with chronic hypoxia.


Assuntos
Túnica Conjuntiva/irrigação sanguínea , Cianose/diagnóstico , Cardiopatias Congênitas/diagnóstico , Microcirculação , Microscopia com Lâmpada de Fenda , Adulto , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Cianose/etiologia , Cianose/fisiopatologia , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Lâmpada de Fenda , Microscopia com Lâmpada de Fenda/instrumentação , Smartphone , Estresse Mecânico , Adulto Jovem
4.
Sci Rep ; 11(1): 7660, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33828174

RESUMO

Microcirculatory dysfunction occurs early in cardiovascular disease (CVD) development. Acute myocardial infarction (MI) is a late consequence of CVD. The conjunctival microcirculation is readily-accessible for quantitative assessment and has not previously been studied in MI patients. We compared the conjunctival microcirculation of acute MI patients and age/sex-matched healthy controls to determine if there were differences in microcirculatory parameters. We acquired images using an iPhone 6s and slit-lamp biomicroscope. Parameters measured included diameter, axial velocity, wall shear rate and blood volume flow. Results are for all vessels as they were not sub-classified into arterioles or venules. The conjunctival microcirculation was assessed in 56 controls and 59 inpatients with a presenting diagnosis of MI. Mean vessel diameter for the controls was 21.41 ± 7.57 µm compared to 22.32 ± 7.66 µm for the MI patients (p < 0.001). Axial velocity for the controls was 0.53 ± 0.15 mm/s compared to 0.49 ± 0.17 mm/s for the MI patients (p < 0.001). Wall shear rate was higher for controls than MI patients (162 ± 93 s-1 vs 145 ± 88 s-1, p < 0.001). Blood volume flow did not differ significantly for the controls and MI patients (153 ± 124 pl/s vs 154 ± 125 pl/s, p = 0.84). This pilot iPhone and slit-lamp assessment of the conjunctival microcirculation found lower axial velocity and wall shear rate in patients with acute MI. Further study is required to correlate these findings further and assess long-term outcomes in this patient group with a severe CVD phenotype.


Assuntos
Túnica Conjuntiva/irrigação sanguínea , Microcirculação , Infarto do Miocárdio sem Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Microvasc Res ; 126: 103907, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31330150

RESUMO

PURPOSE: The conjunctival microcirculation is a readily-accessible vascular bed for quantitative haemodynamic assessment and has been studied previously using a digital charge-coupled device (CCD). Smartphone video imaging of the conjunctiva, and haemodynamic parameter quantification, represents a novel approach. We report the feasibility of smartphone video acquisition and subsequent haemodynamic measure quantification via semi-automated means. METHODS: Using an Apple iPhone 6 s and a Topcon SL-D4 slit-lamp biomicroscope, we obtained videos of the conjunctival microcirculation in 4 fields of view per patient, for 17 low cardiovascular risk patients. After image registration and processing, we quantified the diameter, mean axial velocity, mean blood volume flow, and wall shear rate for each vessel studied. Vessels were grouped into quartiles based on their diameter i.e. group 1 (<11 µm), 2 (11-16 µm), 3 (16-22 µm) and 4 (>22 µm). RESULTS: From the 17 healthy controls (mean QRISK3 6.6%), we obtained quantifiable haemodynamics from 626 vessel segments. The mean diameter of microvessels, across all sites, was 21.1µm (range 5.8-58 µm). Mean axial velocity was 0.50mm/s (range 0.11-1mm/s) and there was a modestly positive correlation (r 0.322) seen with increasing diameter, best appreciated when comparing group 4 to the remaining groups (p < .0001). Blood volume flow (mean 145.61pl/s, range 7.05-1178.81pl/s) was strongly correlated with increasing diameter (r 0.943, p < .0001) and wall shear rate (mean 157.31 s-1, range 37.37-841.66 s-1) negatively correlated with increasing diameter (r - 0.703, p < .0001). CONCLUSIONS: We, for the first time, report the successful assessment and quantification of the conjunctival microcirculatory haemodynamics using a smartphone-based system.


Assuntos
Doenças Cardiovasculares/diagnóstico , Túnica Conjuntiva/irrigação sanguínea , Técnicas de Diagnóstico Oftalmológico/instrumentação , Hemodinâmica , Microcirculação , Lâmpada de Fenda , Smartphone , Adulto , Velocidade do Fluxo Sanguíneo , Doenças Cardiovasculares/fisiopatologia , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Hemorreologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Modelos Cardiovasculares , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional
6.
Am J Cardiol ; 121(1): 9-13, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29103607

RESUMO

Fractional flow reserve (FFR) derived from coronary computed tomography angiography (CTA) is a new technique for the diagnosis of ischemic coronary artery stenoses. The aim of this prospective study was to evaluate the diagnostic performance of a novel on-site computed tomography-based fractional flow reserve algorithm (CT-FFR) compared with invasive FFR as the gold standard, and to determine whether its diagnostic performance is affected by interobserver variations in lumen segmentation. We enrolled 44 consecutive patients (64.6 ± 8.9 years, 34% female) with 60 coronary atherosclerotic lesions who underwent coronary CTA and invasive coronary angiography in 2 centers. An FFR value ≤0.8 was considered significant. Coronary CTA scans were evaluated by 2 expert readers, who manually adjusted the semiautomated coronary lumen segmentations for effective diameter stenosis (EDS) assessment and on-site CT-FFR simulation. The mean CT-FFR value was 0.77 ± 0.15, whereas the mean EDS was 43.6 ± 16.9%. The sensitivity, specificity, positive predictive value, and negative predictive value of CT-FFR versus EDS with a cutoff of 50% were the following: 91%, 72%, 63%, and 93% versus 52%, 87%, 69%, and 77%, respectively. The on-site CT-FFR demonstrated significantly better diagnostic performance compared with EDS (area under the curve 0.89 vs 0.74, respectively, p <0.001). The CT-FFR areas under the curve of the 2 readers did not show any significant difference (0.89 vs 0.88, p = 0.74). In conclusion, on-site CT-FFR simulation is feasible and has better diagnostic performance than anatomic stenosis assessment. Furthermore, the diagnostic performance of the on-site CT-FFR simulation algorithm does not depend on the readers' semiautomated lumen segmentation adjustments.


Assuntos
Algoritmos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada Multidetectores , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes
7.
Catheter Cardiovasc Interv ; 87(1): 134-42, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26010269

RESUMO

INTRODUCTION: There is considerable variability within the population of patients treated with transcatheter aortic valve implantation (TAVI), the procedural approach and time to discharge. In Belfast, from the commencement of our program, our approach has been to perform TAVI by the least invasive approach, where feasible, utilizing a percutaneous transfemoral route and local anesthetic. By analyzing our Belfast TAVI database we identified factors that predicted shorter admission times without impacting adversely on patient safety. Following this, we developed an early discharge pathway. The aim of this current study was to perform a prospective analysis of outcomes in our unit since implementation of this pathway assessing discharge time, mortality, serious adverse events, readmission, and resource implications for patients according to time to discharge. METHODS: Consecutive patients who underwent TAVI and were successfully discharged from 2013 to 2014 over a 14 month period were included, and analyzed according to time to discharge. Baseline and procedural characteristics, mortality, serious adverse events, readmission, and cost were assessed. RESULTS: In total 120 patients were included, 26 (21.7%) were discharged the same/next day, 39 (32.5%) early (>1-4 days), and 55 (45.8%) discharged in the late group. There was no significant difference in baseline or preprocedural characteristics. The incidence of complications was low, and there was no difference in 30-day mortality (P = 0.167) or readmission rates between groups (P = 0.952). Resource analysis revealed the late discharge group cost £3,091.6 more per patient per TAVI than same/next day discharge group. CONCLUSION: Same/next day discharge can be performed safely in appropriately selected patients. Although this will be achieved in a minority of patients (21.7% in this study using an early discharge pathway) it has potential for resource and cost savings. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Recursos em Saúde , Próteses Valvulares Cardíacas , Alta do Paciente/tendências , Medição de Risco , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Feminino , Humanos , Irlanda/epidemiologia , Masculino , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo
8.
Catheter Cardiovasc Interv ; 71(2): 222-8, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18327840

RESUMO

OBJECTIVES: (1) To define patent foramen ovale (PFO) morphology using balloon assessment and identify those with long tunnel type morphology. (2) To describe a novel technique of detunnelisation to facilitate PFO device closure in patients with long tunnel PFO morphology. BACKGROUND: An appreciation that PFO morphology varies from simple defects through to long tunnel-like defects is important for their successful transcatheter closure. Using standard closure techniques for long tunnels can be problematic. METHODS: Consecutive patients who underwent transcatheter PFO closure from April 1, 2005 to March 31, 2006 had assessment of PFO morphology using a compliant sizing balloon. The sites of constraint of the balloon allowed identification of the PFO entrance, exit, and length. The PFO was classified as being a long tunnel when the length was greater than the diameter of either the entrance or exit. Those with a long tunnel had detunnelisation performed and the defect was then closed. RESULTS: 44 patients (32 females), mean age 50 years were studied. On balloon assessment 10 (23%) met the criteria for long tunnels. Detunnelisation allowed successful closure with the STARFlex (NMT Medical, Boston, MA) device in 9 of 10 patients. In the other case transseptal puncture was required after detunnelisation before closure. CONCLUSIONS: Balloon assessment of PFOs enhances the understanding of their morphology and aids the identification of long tunnels. Detunnelisation using the same balloon facilitates the uncomplicated transcatheter closure of long tunnel PFOs in most patients.


Assuntos
Cateterismo/métodos , Forame Oval Patente/patologia , Forame Oval Patente/cirurgia , Implantação de Prótese/métodos , Adulto , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Feminino , Fluoroscopia , Forame Oval Patente/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Cirurgia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA