Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Future Cardiol ; 19(14): 707-718, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37929680

RESUMO

Recently, prognosis and survival of cancer patients has improved due to progression and refinement of cancer therapies; however, cardiovascular sequelae in this population augmented and now represent the second cause of death in oncological patients. Initially, the main issue was represented by heart failure and coronary artery disease, but a growing body of evidence has now shed light on the increased arrhythmic risk of this population, atrial fibrillation being the most frequently encountered. Awareness of arrhythmic complications of cancer and its treatments may help oncologists and cardiologists to develop targeted approaches for the management of arrhythmias in this population. In this review, we provide an updated overview of the mechanisms triggering cardiac arrhythmias in cancer patients, their prevalence and management.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Neoplasias , Humanos , Prevalência , Fibrilação Atrial/complicações , Neoplasias/complicações , Neoplasias/epidemiologia , Neoplasias/terapia , Insuficiência Cardíaca/complicações
2.
Front Cardiovasc Med ; 9: 985182, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439999

RESUMO

Introduction: Unrecognized incomplete pulmonary vein (PV) isolation during the index procedure, can be a major cause of clinical recurrences of atrial fibrillation (AF) after cryoballoon (CB) ablation. We aimed to characterize the extension of the lesions produced by CB ablation and to assess the value of using an ultra-high resolution electroanatomic mapping (UHDM) system to detect incomplete CB lesions. Materials and methods: Twenty-nine consecutive patients from the CHARISMA registry undergoing AF ablation at four Italian centers were prospectively evaluated. The Rhythmia™ mapping system and the Orion™ (Boston Scientific) mapping catheter were used to systematically map the left atrium and PVs before and after cryoablation. Results: A total of 116 PVs were targeted and isolated. Quantitative assessment of the lesions revealed a significant reduction of the antral surface area of the PV, resulting in an ablated area of 5.7 ± 0.7 cm2 and 5.1 ± 0.8 cm2 for the left PV pair and right PV pair, respectively (p = 0.0068). The mean posterior wall (PW) area was 22.9 ± 2 cm2 and, following PV isolation, 44.8 ± 6% of the PW area was ablated. After CB ablation, complete isolation of each PV was documented by the POLARMap™ catheter in all patients. By contrast, confirmatory UHDM and the Lumipoint™ tool unveiled PV signals in 1 out of 114 of the PVs (0.9%). Over 30-day follow-up, no major procedure-related adverse events were reported. After a mean follow-up of 333 days, 89.7% of patients were free from arrhythmia recurrence. Conclusion: The lesion extension achieved by the new CB ablation system involved the PV antrum, with less than 50% of the PW remaining untouched. The new system, with short tip and circular mapping catheter, failed to achieve PV isolation in only 0.9% of all PVs treated. Clinical trial registration: [http://clinicaltrials.gov/], identifier [NCT03793998].

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA