Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
World J Gastroenterol ; 30(12): 1663-1669, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38617743

RESUMO

Liver disease accounts for approximately 2 million deaths per year worldwide. All chronic liver diseases (CLDs), whether of toxic, genetic, autoimmune, or infectious origin, undergo typical histological changes in the structure of the tissue. These changes may include the accumulation of extracellular matrix material, fats, triglycerides, or tissue scarring. Noninvasive methods for diagnosing CLD, such as conventional B-mode ultrasound (US), play a significant role in diagnosis. Doppler US, when coupled with B-mode US, can be helpful in evaluating the hemodynamics of hepatic vessels and detecting US findings associated with hepatic decompensation. US elastography can assess liver stiffness, serving as a surrogate marker for liver fibrosis. It is important to note that interpreting these values should not rely solely on a histological classification. Contrast-enhanced US (CEUS) provides valuable information on tissue perfusion and enables excellent differentiation between benign and malignant focal liver lesions. Clinical evaluation, the etiology of liver disease, and the patient current comorbidities all influence the interpretation of liver stiffness measurements. These measurements are most clinically relevant when interpreted as a probability of compensated advanced CLD. B-mode US offers a subjective estimation of fatty infiltration and has limited sensitivity for mild steatosis. The controlled attenuation parameter requires a dedicated device, and cutoff values are not clearly defined. Quan-titative US parameters for liver fat estimation include the attenuation coefficient, backscatter coefficient, and speed of sound. These parameters offer the advantage of providing fat quantification alongside B-mode evaluation and other US parameters. Multiparametric US (MPUS) of the liver introduces a new concept for complete noninvasive diagnosis. It encourages examiners to utilize the latest features of an US machine, including conventional B-mode, liver stiffness evaluation, fat quantification, dispersion imaging, Doppler US, and CEUS for focal liver lesion characterization. This comprehensive approach allows for diagnosis in a single examination, providing clinicians worldwide with a broader perspective and becoming a cornerstone in their diagnostic arsenal. MPUS, in the hands of skilled clinicians, becomes an invaluable predictive tool for diagnosing, staging, and monitoring CLD.


Assuntos
Fígado Gorduroso , Hepatopatias , Humanos , Hepatopatias/diagnóstico por imagem , Ultrassonografia , Cirrose Hepática/diagnóstico por imagem
2.
Biomedicines ; 11(3)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36979917

RESUMO

The estimation of viscosity by measuring the shear-wave dispersion (SWD) using ultrasound 2D shear-wave elastography (SWE) is becoming more and more popular. Recent research suggests that SWD can be used in addition to 2D-SWE (shear-wave speed) to diagnose diffuse liver disease. Viscosity was studied for the assessment of normal thyroid tissue. This study aims to evaluate the use of viscosity measurements in patients with chronic autoimmune thyroiditis using the SuperSonic MACH®30 ultrasound machine (Hologic SuperSonic Imagine, Aix-en-Provence, France) which provides the Vi PLUS mode for viscosity and the 2D SWE PLUS mode for shear-wave speed measurements. Valid measurements were obtained in 308 cases, 153 with chronic autoimmune thyroiditis (CAT) and 155 with no thyroid pathology (95.95% feasibility of the methods). The differences between the healthy group and the CAT group were statistically significant both for Vi PLUS (2.5 ± 0.4 vs. 2.8 ± 0.5, p < 0.0001) and for 2D-SWE PLUS (13.5 ± 3.3 vs. 23.1 ± 8.3, p < 0.0001). The diagnostic performance was poor for Vi PLUS alone (AUC = 0.69; cut-off > 2.5 Pa·s, se = 68.6%; sp = 64.52%) and good for 2D-SWE PLUS alone (AUC = 0.861; cut-off > 18.4 kPa, se = 69.9%; sp = 92.2%). Vi PLUS correlated with 2D-SWE PLUS, with the presence of CAT, the thyroid volume, levothyroxine replacement therapy and age. Statistically significant differences were found between the CAT subgroup receiving thyroid replacement therapy and the subgroup without therapy: 24.74 ± 8.33 vs. 21.93 ± 8.12 kPa for 2D-SWE (p = 0.0380) and 3 ± 0.5 vs. 2.7 ± 0.4 Pa·s for Vi PLUS (p = 0.0193). Elastography-based methods improve the classic ultrasound evaluation: 2D-SWE PLUS performed somewhat better in distinguishing CAT from normal thyroid tissue, while Vi PLUS made a slightly better assessment regarding the functional status.

3.
J Clin Med ; 11(15)2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-35955985

RESUMO

Elastography is a useful noninvasive tool for the assessment of renal transplant recipients. 2D-shear wave elastography (SWE) PLUS and viscosity plane-wave ultrasound (Vi PLUS) have emerged as novel techniques that promise to offer improved renal stiffness and viscosity measures due to improved processing algorithms. Methods: We performed a cross-sectional study of 50 kidney transplanted patients (16 women, 34 men; mean age of 47.5 ± 12.5; mean estimated glomerular filtration rate (eGFR) estimated by Chronic Kidney Disease Epidemiology Collaboration formula: 52.19 ± 22.6 mL/min/1.73 m2; and a mean duration after transplant of 10.09 ± 5 years). For every patient, we obtained five valid measurements of renal stiffness (obtained from five different frames in the cortex of the renal graft), and also tissue viscosity, with a C6-1X convex transducer using the Ultra-Fast™ software available on the Aixplorer Mach 30 ultrasound system (Supersonic Imagine, Aix-en-Provence, France). The median values of elastographic and viscosity measures have been correlated with the patients' demographic, biological, and clinical parameters. Results: We obtained a cut-off value of renal cortical stiffness of <27.3 kiloPascal(kPa) for detection of eGFR < 60 mL/min/1.73 m2 with 80% sensitivity and 85% specificity (AUC = 0.811, p < 0.0001), a cut-off value of <26.9 kPa for detection of eGFR < 45 mL/min/1.73 m2 with 82.6% sensitivity and 74% specificity (AUC = 0.789, p < 0.0001), and a cut-off value of <23 kPa for detection of eGFR < 30 mL/min/1.73 m2 with 88.8% sensitivity and 75.6% specificity (AUC = 0.852, p < 0.0001). We found a positive correlation coefficient between eGFR and the median measure of renal cortical stiffness (r = 0.5699, p < 0.0001), between eGFR the median measure of viscosity (r = 0.3335, p = 0.0180), between median depth of measures and renal cortical stiffness (r = −0.2795, p = 0.0493), and between median depth of measures and body mass index (BMI) (r = 0.6574, p < 0.0001). Our study showed good intra-operator agreement for both 2D SWE PLUS measures­with an intraclass correlation coefficient (ICC) of 0.9548 and a 95% CI of 0.9315 to 0.9719­and Vi PLUS, with an ICC of 0.8323 and a 95% CI of 0.7457 to 0.8959. The multivariate regression model showed that 2D SWE PLUS values were associated with eGFR, Vi PLUS, and depth of measures. Conclusions: Assessment of renal allograft stiffness and viscosity may prove to be an effective method for identifying patients with chronic allograft injury and could prove to be a low-cost approach to provide additional diagnostic information of kidney transplanted patients.

4.
Diagnostics (Basel) ; 12(6)2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35741261

RESUMO

Liver fibrosis is the most significant prognostic factor in chronic liver disease (CLD). Clinical practice guidelines recommend the use of non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE), to assess liver stiffness as a marker of fibrosis. Several other factors influence liver stiffness in addition to liver fibrosis. It is presumed that changes due to necro-inflammation modify the propagation of shear waves (dispersion). Therefore, new imaging techniques that investigate the dispersion properties of shear waves have been developed, which can serve as an indirect method of measuring liver viscosity (Vi PLUS). Defining the reference values in healthy subjects among different age groups and genders and analyzing the factors that influence these values is essential. However, published data on liver viscosity are still limited. This is the first study that aimed to assess the normal range of liver viscosity values in subjects with healthy livers and analyze the factors that influence them. One hundred and thirty-one consecutive subjects with healthy livers were enrolled in this prospective study. The results showed that Vi PLUS is a highly feasible method. Liver stiffness, age and BMI influenced the liver viscosity values. The mean liver viscosity by Vi PLUS in subjects with healthy livers was 1.59 Pa·s.

5.
Diagnostics (Basel) ; 12(4)2022 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35453941

RESUMO

Malnutrition and sarcopenia are common complications of liver cirrhosis. This study compares the performance of different nutritional assessment techniques in detecting malnourished patients. Data from 156 patients with liver cirrhosis were collected. We assessed the nutritional status of these patients according to: Subjective Global Assessment (SGA); Royal Free Hospital-Nutritional Prioritizing Tool (RFH-NPT), skinfold thickness (TSF), mid-upper arm circumference (MUAC), mid-upper arm muscle circumference (MUMC), handgrip strength (HGS), body mass index (BMI), and skeletal muscle index (SMI) evaluated by Contrast-Enhanced Computed Tomography (CT). According to EWGSOP2 criteria, combining low HGS with low SMI, the prevalence of malnutrition/sarcopenia was 60.2%. RFH-NPT, MUAC, MAMC, and HGS were excellent tests for detecting malnourished patients. Combining RFH-NPT with MUAC or MUMC increased diagnosis accuracy, AUC = 0.89, p < 0.0001. Age, Child-Pugh class C, albumin level, vitamin D deficiency, male gender, and alcoholic etiology were significantly associated with malnutrition. In conclusion, the prevalence of malnutrition among patients with cirrhosis was relatively high. Our study highlights the potential use of a simpler and inexpensive alternative that can be used as a valuable tool in daily practice, the combination between RFH-NPT and MUAC.

6.
Med Ultrason ; 23(2): 140-146, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-33945596

RESUMO

AIM: Contrast-enhanced ultrasound (CEUS) has become a relevant imaging method for the evaluation of focal liver le-sions (FLL). The aim of this study was to evaluate the performance of CEUS for the assessment of focal nodular hyperplasia (FNH) in a large study group. MATERIAL AND METHODS: We performed a multicentre prospective observational study, which included successive CEUS examinations from fourteen Romanian centres. CEUS examinations were performed in de novo FLL, using low mechanical index ultrasound, following an intravenous bolus of 2.4 ml SonoVue. CEUS was considered conclusive for FNH if a typical pattern was present following contrast (rapid "spoke-wheel" enhancement during the arterial phase, hyperenhanced lesion during venous phase, hyper- or isoenhanced in the late phase). In all cases a reference method was available (contrast enhanced CT or MRI or biopsy). The trial was registered in clinicaltrials.gov (Identifier NCT01329458). RESULTS: During the 6 years study, 2062 "de novo" FLL were evaluated by CEUS. From this cohort, 94/2062 (4.5%) had a typical enhancing pattern for FNH as described in the EFSUMB guidelines. Contrast enhanced CT/MRI and biopsy diagnosed additional 15 FNH. From the 94 cases diagnosed as FNH by CEUS, in nine the final diagnosis was different (five of them adenomas). CEUS had 85% sensitivity, 99.5% specificity, 90.4% positive predictive value, 99.2% negative predictive value and 98.8% diagnostic accuracy for the diagnosis of FNH. CONCLUSIONS: CEUS is a sensitive and very specific method for the diagnosis of FNH.


Assuntos
Hiperplasia Nodular Focal do Fígado , Meios de Contraste , Diagnóstico Diferencial , Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Humanos , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Ultrassonografia
7.
Med Ultrason ; 23(3): 257-264, 2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-33657193

RESUMO

AIMS: We aimed to compare the diagnostic performance of two 2D-Shear Wave Elastography (2D-SWE) techniques for the non-invasive assessment of liver fibrosis in patients with chronic hepatitis C virus (HCV) infection using Transient Elas-tography (TE) as reference. MATERIAL AND METHODS: We enrolled 208 consecutive patients with chronic HCV infection, in which liver stiffness (LS) was evaluated in the same session using two 2D-SWE techniques: 2D-SWE.GE and 2D-SWE.SSI using TE as the method of reference. LS measurements were considered failures when no value was obtained after 10 attempts. RESULTS: Valid LSMs were obtained in 95.6% (199/208) of cases by 2D-SWE.GE, 92.7% (193/208) of cases by 2D-SWE.SSI, and in 94.7% (197/208) of cases by TE (p>0.05). The mean LS values by 2D-SWE.GE were significantly lower than those obtained by 2D-SWE.SSI: 10.3±3.8 kPa vs. 15±10.4 kPa (p<0.0001). 2D-SWE.GE LSMs correlated better with TE than 2D-SWE.SSI (r=0.75, p<0.0001 vs. r=0.57, p<0.0001, z test p=0.0012). Linear regression analysis showed a moderate correlation between LSMs obtained by 2D-SWE.GE and 2D-SWE.SSI (r=0.63, R2=0.4, P<0.0001). Pairwise comparison of receiver operating characteristics curves (ROC) found no significant differences between 2D-SWE.GE and 2D-SWE.SSI in identifying F≥2 fibrosis (0.97 vs. 0.96, P = 0.5650), F≥3 (0.97 vs. 0.95, P = 0.2935), or F=4 (0.97 vs. 0.96, p = 0.6914). CONCLUSIONS: Both 2D-SWE techniques had good feasibility for the noninvasive assessment of liver fibrosis. LS values obtained by 2D-SWE.GE were significantly lower than those obtained by 2D-SWE.SSI. No significant differences were found between both methods in staging liver fibrosis in patients with chronic HCV.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite C Crônica , Hepatite C , Cirrose Hepática , Hepatite C/patologia , Hepatite C Crônica/complicações , Hepatite C Crônica/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/etiologia , Cirrose Hepática/patologia , Curva ROC
8.
Ultrasound Med Biol ; 46(11): 2979-2988, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32807571

RESUMO

The study compared the diagnostic performance of two shear-wave elastography techniques, elastography point quantification (ElastPQ) and 2-D shear-wave elastography by General Electric (2-D-SWE.GE), for the non-invasive assessment of liver fibrosis in a cohort of patients with chronic hepatitis C virus (HCV) infection, using transient elastography (TE) as the reference method. There was no significant difference between the feasibility rates of TE, ElastPQ and 2-D-SWE.GE (p = 0.507). A good correlation was found between the liver stiffness (LS) values obtained using the two elastographic methods (r = 0.78). The mean LS values obtained using the ElastPQ technique were significantly higher than those obtained using 2-D-SWE.GE (12.1 ± 7.3 kPa vs. 10.4 ± 4.0 kPa, p < 0.0001). Pairwise comparisons of receiver operator characteristics curves between 2-D-SWE.GE and ElastPQ have shown that there are no significant differences in their performance for staging F ≥ 2 fibrosis (p = 0.89), F ≥ 3 fibrosis (p = 0.76) and F = 4 fibrosis (p = 0.86) in patients with chronic HCV infection.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite C Crônica/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Idoso , Estudos Transversais , Feminino , Hepatite C Crônica/complicações , Humanos , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Valores de Referência
10.
J Gastrointestin Liver Dis ; 29(2): 181-190, 2020 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-32530985

RESUMO

AIMS: Our aim was to assess the diagnostic performance of transient elastography (TE) and Virtual Touch Quantification (VTQ), a point Shear Wave Elastography (pSWE) technique, using Acoustic Radiation Force Impulse (ARFI) technology, for liver fibrosis assessment, as compared to percutaneous liver biopsy (LB), in patients with chronic hepatitis B or C. METHODS: We analyzed 157 patients (80 with chronic hepatitis B and 77 with chronic hepatitis C) with reliable liver stiffness (LS) measurements, in whom we compared TE and VTQ to the LB performed during the same session (evaluated according to the Metavir scoring system: F0-F4). LS was assessed by TE (FibroScan, EchoSens, Paris, France) and VTQ using the Siemens Acuson S2000TM ultrasound system (Siemens AG, Erlangen, Germany). We defined reliable LS measurements as the median value of 10 measurements with an IQR/M <30% for both TE (obtained using the M probe) and VTQ. The areas under receiver operating characteristic curves (AUROCs) were used to assess the diagnostic performance of TE and VTQ. Correlation analysis determined the relationship between LSM values and liver histology. RESULTS: On LB 31 (19.7%) patients had no fibrosis, 35 (22.3%) had F1, 43 (27.4%) had F2, 28 (17.8%) had F3 and 20 (12.7%) had cirrhosis. The mean size of the liver specimen in LB was 27 mm. A strong, linear correlation (Spearman ρ=0.826; p<0.001) with 95% confidence interval for rho (0.769- 0.870), was found between the TE and VTQ measurements. By comparing the AUROC curves, TE and VTQ had similar predictive values for the presence of F≥1 Metavir: AUROC TE=0.876, AUROC VTQ=0.832, p=0.358, for F≥2 Metavir: AUROC TE=0.826, AUROC VTQ=0.862, p=0.313, for F≥3 Metavir: AUROC TE=0.907, AUROC VTQ=0.880, p=0.434 and for F=4 Metavir: AUROC TE=0.981, AUROC VTQ=0.974, p= 0.423. CONCLUSIONS: Both methods, TE and VTQ (pSWE) offer excellent diagnostic accuracy for liver fibrosis assessment in patients with chronic hepatitis B or C with similar performance.


Assuntos
Biópsia/métodos , Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica , Hepatite C Crônica , Cirrose Hepática , Feminino , Hepatite B Crônica/complicações , Hepatite B Crônica/patologia , Hepatite C Crônica/complicações , Hepatite C Crônica/patologia , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/etiologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Valores de Referência , Reprodutibilidade dos Testes , Projetos de Pesquisa , Romênia
11.
Diagnostics (Basel) ; 10(4)2020 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-32225078

RESUMO

Given the increased prevalence of thyroid nodules in the general population (~50%), the real challenge resides in correctly recognizing the suspicious ones. This study proposes to compare four important Thyroid Imaging and Reporting Data Systems (TI-RADS) and evaluate the contribution of elastography and 4D Color Doppler assessment of vascularity in estimating the risk of malignancy. In the study, 133 nodules with histopathological examination were included. Of these, 35 (26.31%) proved to be malignant. All nodules were classified using the four selected systems and our proposed improved score. The American College of Radiology (ACR) and EU TI-RADS had good sensitivity (94.28%, 97.14%) and NPV (93.33%, 95.83%), but fairly poor specificity (31.81%, 23.46%) and PPV (35.48%, 31.19%), with an accuracy of 42.8% and 45.8%, respectively. Horvath TI-RADS had better accuracy of 66.9% and somewhat improved specificity (62.24%), but poorer sensitivity (80%). Russ' French TI-RADS includes elastography in the risk assessment strategy. This classification proved superior in all aspects (Se: 91.42%, Sp:82.65%, NPV:96.42%, PPV:65.30%, and Acc of 84.96%). The mean strain ratio (SR) value for malignant lesions was 5.56, while the mean SR value for benign ones was significantly lower, 2.54 (p < 0.05). It also correlated well with the response variable: histopathological result (p < 0.001). Although, adding 4D vascularity to the French score generated a similar calculated accuracy and from a statistical point of view, the parameter itself proved beneficial for predicting the malignancy risk (p < 0.001) and may add important knowledge in uncertain situations. Advanced ultrasound techniques definitely improved the risk estimation and should be used more extensively.

12.
Ultrasound Q ; 37(2): 144-148, 2019 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-31166295

RESUMO

ABSTRACT: This study aimed to analyze the utility of bidimensional shear-wave elastography for renal assessment and in the prediction of chronic kidney disease (CKD).The study included 92 subjects: 50 healthy volunteers and 42 patients with different degrees of CKD (mean age, 57.5 ± 13.4; 50% were female), excluding those undergoing renal replacement therapies, obstructive pathology, or renal lithiasis. We performed kidney shear-wave velocity (KSWV) determinations in the midportion of the parenchyma of each kidney. The median values were expressed in meters per second.We obtained successful assessments in 94% of the cases for the right kidney (RK) and 90.2% for the left kidney (LK), with an intraclass correlation coefficient of 0.96 (RK) and 0.91 (LK). We obtained significantly lower KSWV values in the CKD lot as opposed to the healthy volunteers: RK: 1.38 ± 0.1 versus 1.78 ± 0.1 m/s, P = 0.05; LK: 1.37 ± 0.1 m/s versus 1.72 ± 0.1 m/s. We could predict the presence of CKD with a sensitivity of 89.2% and a specificity of 76.9% for a KSWV of less than 1.47 m/s, with a tendency of KSWV to decrease with CKD progression.Our study shows that KSWV measured using bidimensional shear-wave elastography decreases in patients with CKD compared with normal subjects, and that for a cutoff value of below 1.47 m/s we could predict, with a good sensitivity and specificity, the presence of CKD.

13.
Med Ultrason ; 20(3): 265-271, 2018 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-30167577

RESUMO

AIMS: Non-invasive methods to assess the severity of chronic liver diseases have become more and more popular. The aim of our study was to evaluate the correlation of four Shear Waves Elastographic methods in a cohort of patients with chronic liver diseases of mixed etiologies and to compare their performances for liver fibrosis evaluation. MATERIAL AND METHODS:  A prospective study was conducted on 127 consecutive patients with chronic liver diseases of mixed etiologies. LS measurements were performed in all subjects, in one session, during the same day, by means of 4 elastographic methods: Transient Elastography (TE), Virtual Touch Quantification (VTQ), ElastPQ and 2D-SWE.SSI. The diagnosis accuracies of VTQ, ElastPQ, 2D-SWE.SSI were then compared using TE as reference method. RESULTS: Valid LS measurements by all four shear waves ultrasound elastographic methods were obtained in 116/127 subjects with VTQ, in 108/127 subjects with 2D-SWE.SSI, in 111/127 with TE and in 109/127 with ElastPQ, so the final analysis included 82/127 subjects (64.5%). A good and significant correlation was found between all 4 elastographic methods. The diagnostic accuracy of VTQ, 2D-SWE.SSI and ElastPQ for the diagnosis of significant and severe fibrosis (F2/F3), and liver cirrhosis were similar for all elastographic techniques: VTQ vs 2D-SWE.SSI vs ElastPQ: 84.1% vs 85.3% vs. 84% (p>0.05); 93.9% vs 94% vs 94% (p>0.05). CONCLUSION: considering TE as the reference method for liver fibrosis evaluation, VTQ, ElastPQ, and 2D-SWE.SSI obtained similar accuracies for diagnosing at least significant fibrosis (F≥2) and liver cirrhosis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Ultrassonografia Doppler/métodos , Adulto , Idoso , Biópsia por Agulha , Doença Crônica , Estudos de Coortes , Feminino , Humanos , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
14.
Dig Liver Dis ; 50(10): 1056-1061, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29705030

RESUMO

BACKGROUND: Assessment of liver stiffness provides important diagnostic and prognostic information in patients with chronic liver disease. AIMS: To investigate whether the use of quality criteria (i) improves the concordance between transient elastography (TE) and a novel point shear wave elastography technique (ElastPQ®) and (ii) impacts on the performance of ElastPQ® for liver fibrosis staging using TE as the reference standard. METHODS: In this multicenter retrospective study, data of patients undergoing liver stiffness measurements (LSM) in five European centers were collected. TE was performed with FibroScan® (Echosens, France) and ElastPQ® with EPIQ® or Affiniti® systems (Philips, The Netherlands). The agreement between TE and ElastPQ® LSMs was assessed with Lin's concordance correlation coefficient (CCC). Diagnostic performance of ElastPQ® was assessed by the area under receiver operating characteristic (AUROC) curves. RESULTS: Overall, 664 patients were included: mean age: 54.8(13.5) years, main etiologies: viral hepatitis (83.1%) and NAFLD (7.5%). CCC increased significantly when LSMs with ElastPQ® were obtained with IQR/M ≤ 30% (p < 0.001). The diagnostic performance of ElastPQ® for fibrosis staging also increased if LSM values were obtained with IQR/M ≤ 30%. CONCLUSION: Quality criteria should be followed when using ElastPQ® for LSM, since the concordance with TE fibrosis staging was better at an ElastPQ® IQR/M ≤ 30.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Fidelidade a Diretrizes , Cirrose Hepática/diagnóstico por imagem , Fígado/patologia , Adulto , Idoso , Área Sob a Curva , Europa (Continente) , Feminino , Humanos , Cirrose Hepática/etiologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
15.
Hepatology ; 67(1): 260-272, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28370257

RESUMO

Two-dimensional shear wave elastography (2D-SWE) has proven to be efficient for the evaluation of liver fibrosis in small to moderate-sized clinical trials. We aimed at running a larger-scale meta-analysis of individual data. Centers which have worked with Aixplorer ultrasound equipment were contacted to share their data. Retrospective statistical analysis used direct and paired receiver operating characteristic and area under the receiver operating characteristic curve (AUROC) analyses, accounting for random effects. Data on both 2D-SWE and liver biopsy were available for 1,134 patients from 13 sites, as well as on successful transient elastography in 665 patients. Most patients had chronic hepatitis C (n = 379), hepatitis B (n = 400), or nonalcoholic fatty liver disease (n = 156). AUROCs of 2D-SWE in patients with hepatitis C, hepatitis B, and nonalcoholic fatty liver disease were 86.3%, 90.6%, and 85.5% for diagnosing significant fibrosis and 92.9%, 95.5%, and 91.7% for diagnosing cirrhosis, respectively. The AUROC of 2D-SWE was 0.022-0.084 (95% confidence interval) larger than the AUROC of transient elastography for diagnosing significant fibrosis (P = 0.001) and 0.003-0.034 for diagnosing cirrhosis (P = 0.022) in all patients. This difference was strongest in hepatitis B patients. CONCLUSION: 2D-SWE has good to excellent performance for the noninvasive staging of liver fibrosis in patients with hepatitis B; further prospective studies are needed for head-to-head comparison between 2D-SWE and other imaging modalities to establish disease-specific appropriate cutoff points for assessment of fibrosis stage. (Hepatology 2018;67:260-272).


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica/complicações , Hepatite C Crônica/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Bases de Dados Factuais , Progressão da Doença , Feminino , Seguimentos , Hepatite B Crônica/diagnóstico por imagem , Hepatite B Crônica/patologia , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/patologia , Humanos , Imuno-Histoquímica , Cirrose Hepática/etiologia , Cirrose Hepática/virologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Curva ROC , Índice de Gravidade de Doença , Adulto Jovem
16.
Ultrasound Med Biol ; 43(10): 2159-2166, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28720285

RESUMO

In previous studies of acoustic radiation force impulse (ARFI) elastography, using Virtual Touch tissue quantification (VTQ) (Siemens Acuson S2000), it was reported that the measurement of renal shear wave speed in patients with chronic kidney disease (CKD) is not influenced exclusively by renal fibrosis. The purpose of the present study was to analyze the role of VTQ in patients with diabetic kidney disease, considered the main cause of CKD. The study group included 164 patients: 80 patients with diabetic kidney disease (DKD) and 84 without renal disease or diabetes mellitus. In each subject in lateral decubitus, five valid VTQ measurements were performed in each kidney and a median value was calculated, the result being expressed in meters/second. The following means of the median values were obtained In DKD patients, the means of the median values were for VTQ right kidney, 2.21 ± 0.71 m/s, and for VTQ left kidney, 2.13 ± 0.72 m/s, whereas in the normal controls statistically significant higher values were obtained: 2.58 ± 0.78 m/s for VTQ right kidney (p = 0.0017) and 2.46 ± 0.81 m/s for VTQ left kidney (p = 0.006). Patients with an estimated glomerular filtration rate (eGFR) >60 mL/min (DKD stages 1 and 2 together with normal controls) had a significantly higher kidney shear wave speed compared with patients with an eGFR <60 mL/min (2.53 m/s vs. 2.09 m/s, p < 0.05). In the DKD group, there was a significant correlation between eGFR and VTQ levels for the right kidney (r = 0.28, p = 0.04). There was no correlation of VTQ values with proteinuria level, stage of diabetic retinopathy or glycated hemoglobin. Our study indicates that shear wave speed values in patients with diabetic kidney disease and eGFRs <60 mL/min are significantly lower compared with those of patients with eGFRs >60 mL/min (either normal controls or diabetic patients with DKD stages 1 and 2), and values decrease with the decrease in eGFR. However, proteinuria, diabetic retinopathy and glycated hemoglobin have no influence on VTQ.


Assuntos
Nefropatias Diabéticas/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Adulto , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Clujul Med ; 90(1): 28-32, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28246494

RESUMO

The aim of the paper was to propose a score for performance evaluation in colonoscopy units. METHOD: We proposed a score (CDCD score - Cecal intubation, polyp Detection rate, Cleansing and Documentation of cecal intubation) based on the following parameters that assess the quality of colonoscopy units: total colonoscopies rate, polyp detection rate, rate of cecal intubation photo record, rate of recorded Boston bowel preparation scale (BBPS) (rated 1 to 5 stars). The mean score obtained based on the above mentioned criteria was used as a quality parameter of the endoscopy unit. We applied and calculated this score in all screening colonoscopies performed in our Endoscopy Department during the last 4 years. RESULTS: The study group included 856 screening colonoscopies. The rate of total colonoscopies was 92.1% (789/856 cases) and the polyp detection rate was 23.9%. Regarding the quality of bowel preparation, the BBPS was recorded in 51.1% cases. The cecal intubation was photo recorded in 44% of cases. We considered that of the 4 parameters, the highest weight for an excellent quality belonged to the cecal intubation rate, followed by the polyp detection rate, because they evaluate the endoscopic technique, while the other 2 are more administrative. Thus, for the unit's assessment we used the following equation: UNIT'S QUALITY CDCD SCORE = (3×cecal intubation rate+3×polyp detection rate+1×photo documentation+1×BBPS documentation)/8. Thus, the CDCD Score for our unit was ≈4 stars (3.7 stars). CONCLUSION: The proposed CDCD score may be an objective tool for the quality assessment in different endoscopy units.

19.
Med Ultrason ; 16(2): 119-22, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24791843

RESUMO

OBJECTIVE: Liver stiffness measurement (LSM) using Transient Elastography (TE) for liver fibrosis assessment is difficult to be performed in obese and overweight patients by standard M probe, thus the XL probe was developed. The aim of our paper was to assess the usefulness of the XL probe in daily clinical practice. MATERIAL AND METHOD: Our study included 216 patients (mean BMI 30.1+/-4.1 kg/m2) with chronic hepatopathies, in which paired measurements were made using the M (3.5MHz) and XL (2.5 MHz) probes in the same session. In each patient 10 valid LSM were acquired with each probe, a median was calculated, expressed in kiloPascals (kPa). Unreliable TE measurements were considered: fewer than 10 valid shots; with a success rate (SR) <60% and/or interquartile range interval (IQR) ≥30%. RESULTS: In 127 patients reliable LSM could not be obtained by standard M probe, 10 of them normal weight, 25 of them overweight, and 92 obese. By XL probe reliable measurements were obtained in 80/127(63%) of these patients: 8/10 (80%) of the normal weights, 17/25 (68%) of the overweight and 55/92 (59.8%) of the obese. In 98 patients with reliable M probe measurements, XL probe LSMs were also performed. XL LS values strongly and significantly correlated with those obtained by M probe (Spearman r=0.789, p<0.0001), but were significantly lower [median 6.4 kPa (range 3.1 - 53.8) vs 7.7 kPa (range 3.7-69.1), Wilcoxon paired t test p<0.001)]. CONCLUSION: By using the XL probe, reliable LSM by TE can be obtained in more than 60% of patients with unreliable measurements by M probe. LSM by XL probe are significantly correlated, but lower, than those obtained by M probe.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Cirrose Hepática/diagnóstico por imagem , Transdutores , Adulto , Idoso , Índice de Massa Corporal , Desenho de Equipamento , Feminino , Hepatite B Crônica/diagnóstico por imagem , Hepatite C Crônica/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Sobrepeso/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA